Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Construction Of Cast-In-Place Piles With Enlarged Bases

    By H. Mori

    Construction of cast-in-place piles with enlarged bases has become popular in the cities in Japan facing to the sea coast, where the subground soil is soft alluvium deposited to depths often exceeding

    Jan 1, 1989

  • DFI
    Correlations From In Situ Compression, Pull-Out & Lateral Load Tests On Piles ? Synopsis

    By Madhira R. Madhav

    In an alluvial deposit consisting of layers of sandy silt with clay and kankar nodules, driven cast in situ piles are provided. The piles end on a stiff bearing stratum To verify the available design

    Jan 1, 1996

  • DFI
    Analyses Of Dynamic Increasing Energy Load Test On Deep Foundations

    By Silvana B. Foá

    Results from full-scale loading tests showed the use of the dynamic increasing energy test (DIET) to verify the capacity of deep foundations. This method allows the measurement of dynamic resistance -

    Jan 1, 2002

  • DFI
    Interactive Encased Stone-Column Foundation - Synopsis

    By P. M. Deshpande

    An interactive short column system is evolved as alternative to deep foundation system in deep layers of marine clay, the interaction of encased stone column and marine clay carry load without causing

    Jan 1, 1996

  • DFI
    Base Grouted Piles In Thanet Sands, London

    By D. E. Sherwood

    Twelve toe grouted, and eleven ungrouted piles, founded in very dense sands have been analysed to establish how toe grouting enhances pile performance. It is shown that pile stiffness is greatly incre

    Jan 1, 1989

  • DFI
    Application Of Several Soil Improvement Methods In China

    By J. H. Qian

    China is one of the countries with comparatively wide distribution of soft soil. In the wake of the rapid developement in the national economy and construction, the improvement technique of soft soil

    Jan 1, 2010

  • DFI
    Slope Stabilization: Single Versus Staggered Piles

    By A. J. Metz, Roberto Nevarez

    One popular method to stabilize slopes is the use of deep foundation elements to support lateral loads from an unstable soil or rock mass. Drilled deep foundation elements are often selected due to lo

    Nov 1, 2023

  • DFI
    Ground Energy Systems In London - A Best Practice Approach

    By Ryan Law

    Ground energy systems are being installed in increasing numbers in the United Kingdom. This is particularly true in London where planning regulations require larger scale developments to provide at l

    Jan 1, 2008

  • DFI
    Performance Of Toe-Grouted Large Bored Pile In Sand-Gravel Formation Of Chiang Mai City, Northern Thailand

    By Narong Thasnanipan

    Performance of diameter 1.5 m toe-grouted bored pile founded at depth 44 m in sand-gravel formation of Chiang Mai City is presented in this paper. Toe grouting was applied by using tube-a-manchette me

    Jan 1, 2002

  • DFI
    A Terminal Upgrade

    By W. Morgan NeSmith

    The city of Kansas City, Missouri, is replacing its original airport, con- structed in 1972 as a "drive-to-the- gate" facility, with a modern, single- terminal facility with just over 1 million sq ft

    Oct 1, 2022

  • DFI
    Optimization Of Pile Length Using Decision Analysis With Information From Load Tests During Construction

    By Jiun-Yih Chen

    Pile load tests are regularly used to verify pile capacities. Sometimes, they are used to optimize pile designs. This paper presents a case study based on a real project, in which the information ob

    Jan 1, 2009

  • DFI
    Laterally Loaded Model Piles In Jointed Soft Rock Masses

    By B. Francis

    Literature provides only limited information regarding the behaviour of laterally loaded piles socketed into weak rock masses. A laboratory program, comprising a number of tests of scaled models of th

    Jan 1, 2004

  • DFI
    Errata (5268ac87-18a9-458e-b334-4f72060324e3)

    Volume 1 pages 665-671 Title should read as Dynamic pile testing of H-piles at HDB sites J.Wei, Y. S. Heng, C. S. Lok, M. K.Chong Housing and Development Board, Singapore 'tons'

    Jan 1, 1994

  • DFI
    Helical Piles With Grouted Shafts - A Case History

    By Shawn Downey

    A helical pile with in-situ grouted shaft was used to underpin the existing slab of a large retail store in the Edmonton, Alberta Canada area. The existing structural slab did not have the capacity to

    Jan 1, 2003