Helical Piles With Grouted Shafts - A Case History

Deep Foundations Institute
Shawn Downey
Organization:
Deep Foundations Institute
Pages:
7
File Size:
534 KB
Publication Date:
Jan 1, 2003

Abstract

A helical pile with in-situ grouted shaft was used to underpin the existing slab of a large retail store in the Edmonton, Alberta Canada area. The existing structural slab did not have the capacity to support the increased load requirements. The design to upgrade the capacity specified a drilled shaft as the deep foundation to underpin a portion of the slab. A helical pile was quoted as an alternate and ultimately won the bid based on the advantages of the system. After an ASTM D1143 Quick Load Test confirmed the axial compression capacity, 723 helical piles with grouted shafts were installed in 3 weeks underpinning 40% of the 93,000 ft2 (8,660 m2) building.
Citation

APA: Shawn Downey  (2003)  Helical Piles With Grouted Shafts - A Case History

MLA: Shawn Downey Helical Piles With Grouted Shafts - A Case History. Deep Foundations Institute, 2003.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account