  • DFI
    Structure Monitoring During Underpinning

    By Barry C. Roth

    A Real Time Automated Remote Reading Electrolytic Tilt Monitoring System was effectively deployed for monitoring an existing five story brick building during underpinning, shoring and excavation opera

    Jan 1, 2007

  • DFI
    Application Of Several Soil Improvement Methods In China

    By J. H. Qian

    China is one of the countries with comparatively wide distribution of soft soil. In the wake of the rapid developement in the national economy and construction, the improvement technique of soft soil

    Jan 1, 2010

  • DFI
    Vertical Load Carrying Capacity Of Concrete Expanded Base Piles

    By Mustapha Zergoun

    This paper presents the results of load tests to assess the vertical load carrying capacity of concrete expanded base piles, or pressure injected footings, for various projects located near Vancouver,

    Jan 1, 2004

  • DFI
    Recent Advances in Quiet & Vibration-less Steel Pile Installation

    By R. K. Filip

    "Steel bearing piles have long been used to carry high compressive, tensile and lateral loads. Such piles are most commonly tubular or ""H"" profile and are typically installed using percussive techni

    Jan 1, 2005

  • DFI
    Field Tests Of Soft Clay Stabilized By Stone Columns In Coastal Areas In China (325b7cc0-aff5-4a88-9f69-cd3dc2f57f1d)

    By Han Jie

    The results of full scale plate load tests on stone columns on soft clay in coastal areas are presented in this paper. Four load tests were made, two of which were performed on the ground treated with

    Jan 1, 1991

  • DFI
    A Field Study to Analyze Pile Setup Behavior and Comparison of Pile Capacity Methods from CPT

    By Md. Nafiul Haque, Murad Y. Abu-Farsakh, Chris Nickel

    "This paper presents the results from a pile load testing program for a bridge construction project in Louisiana. The testing includes two 54-inch open-ended spun cast concrete cylinder piles (OECP),

    Jan 1, 2017

  • DFI
    Suwanee American Cement Plant, Branford, Florida: A Case Study Of Large Diameter Continuous Flight Auger Design Build Foundations

    By Gordon King

    This paper presents a case study of large diameter continuous flight auger (CFA) piles and drilled shafts utilized for foundation support of a series of heavily loaded cement plant structures at the S

    Jan 1, 2003

  • DFI
    Electronic Instrumentation in Support of Installation of Special Foundation Projects as Part of the Digital Future - Ensuring Safe Production and Improving Quality Control

    By Franz-Werner Gerressen

    New developments are required each day as our industry becomes more competitive. To improve performance, continue and to ensure future demands can be met. This requires the development of technical su

    Jan 1, 2019

  • DFI
    Lateral Load Tests on Step Tapered Bored Piles in Calcareous Sands

    By Nabil F. Ismael, Mohamed El Deeb

    "The behavior of laterally loaded step tapered bored piles in calcareous sand was examined by field tests. Lateral load tests were carried out on straight and step tapered bored piles 5.3 m long embed

    Jan 1, 2005

  • DFI
    Ultimate Bearing Capacity of Small-Diameter Pin-Piles and the Influence of Driving Penetration Resistance

    By Glen Mann, H. G. Vestberg, Robert D. Holtz

    "Underpinning of residential and commercial structures is often accomplished using a number of driven-in-place small diameter steel pipe piles. These piles, at least in the Seattle area, are typically

    Jan 1, 2005

  • DFI
    Extensive Pile Testing of Auger Pressure Grouted Displacement (APGD) Piles, Los Angeles, California

    By Todd W. Armstrong, Michael D. Reader

    "INTRODUCTIONThe Playa Vista Development is the largest urban infill development in the history of the United States. Overall, it encompasses about 1100 acres in the City of Los Angeles and is situate

    Jan 1, 2005

  • DFI
    Costa Rica Circunvalacion Norte Project: Lessons Learned From Foundation Drilling

    By Bernardo J. Jiménez, Harlem Lora, Roberto Acosta Mora

    Circunvalacion Norte project is currently the most important infrastructure project in Costa Rica. It is the last segment of the urban perimeter highway. Site investigation of local geotechnical condi

  • DFI
    Designed, Load Tested, Installed, And Integrity Tested ACIP Piles At Lovers' Key Site In Southwest Florida

    By Gregory A. Stephan

    A case history of design, prediction, instrumented static load tests on probe piles, installation monitoring, and integrity testing of production piles is presented. Based upon project-specific subsoi

    Jan 1, 1999

  • DFI
    Analysis On The Vertical Bearing Capacity Of Socketed Piles

    By Yong Jingrong

    Based on the results of several test socketed piles in Sichuan, the mechanism of the deformation for a loaded socketed piles is investigated, and the concept of the socketed effect is proposed. The be

    Jan 1, 1991

  • DFI
    Sonar Calipering Of Slurry Constructed Drilled Shafts - Providing Quality Assurance And Quality Control In Deep Foundations

    By Denton A. Kort

    Historically the visual examination of drilled shafts to determine shape was typically done under dry conditions. Many engineers believe that by using a dry method of construction, the question of sha

    Jan 1, 2007

  • DFI
    Osterberg Cell Tests Confirm In-Situ Pier Capacity In Colorado - Introduction

    By William Siegel

    Kleinfelder provided foundation analysis and design for an expansion to a cement plant in Florence, Colorado. The expansion was a conversion from a horizontal wet process to a vertical dry process, a

    Jan 1, 2007

  • DFI
    Slurry Trench Design and Construction in Difficult Conditions

    By Peter Deming

    "PART 2 OF 2 (CONTINUED FROM SUMMER 2006 EDITION) CONSTRUCTION ISSUES (cont’d) The Influence of Ground Conditions on Collapse Sand and gravel strata provide frictional resistance to support active ear

    Jan 1, 2006

  • DFI
    Design And Load Test Of Micropiles In A Power Plant In Missouri

    By Bidjan Ghahreman

    A total of 120 micropiles were constructed for foundations of a new selective catalytic reduction (SCR) unit in a coal-fired power plant east of Kansas City, Missouri. Construction was performed unde

    Jan 1, 2009

  • DFI
    Effects Of Environment On Deep Foundation Elements - Synopsis

    By Subhash B. Bhide

    Deep foundations are affected by the presence of sulphates, chlorides, organic contents and water currents present in the soil. The sulphates in soil and ground water interfere first with setting of c

    Jan 1, 1996

  • DFI
    Integrity Testing Methods

    "Integrity tests refer to a variety of non-destructive tests (NDT) whose purpose is to measure or determine the quality and uniformity, and some- times dimensions, of cast-in-place concrete foundation

    Jan 1, 2004