Ultimate Bearing Capacity of Small-Diameter Pin-Piles and the Influence of Driving Penetration Resistance

- Organization:
- Deep Foundations Institute
- Pages:
- 14
- File Size:
- 6467 KB
- Publication Date:
- Jan 1, 2005
Abstract
"Underpinning of residential and commercial structures is often accomplished using a number of driven-in-place small diameter steel pipe piles. These piles, at least in the Seattle area, are typically described as pin-piles and are driven with an air compressor operated jack hammer to a refusal criterion developed from an empirical basis. Over the past twenty years or so, the materials have improved in quality and strength, and the driving equipment has improved in efficiency and capability. These improvements have resulted in damage to the pin-piles during driving as well as to the driving equipment. The primary objectives of this load testing study were to develop a relationship between the driving penetration resistance of 2-inch diameter pin-piles and the ultimate bearing capacity when piles were driven at different penetration rates and, based on the load test results, to develop an opinion regarding an increase in the allowable axial load capacity [ultimate load capacity divided by a factor of safety] of a 2-inch diameter pin-pile over the currently used permissible load capacity of 4 kips in the Seattle area. Also, if feasible, a reduction in the present driving penetration rate was to be recommended to help reduce the rate and magnitude of pile and equipment damage whilst maintaining the allowable load capacity. The recorded ultimate bearing capacities were also compared with the Tagnent-line and the Davisson analytical methods in an effort to determine if either of these provided a reasonable determination of the pile load capacity.IntroductionThis paper describes the results of a series of load tests performed on small diameter, 2-inch, driven-in-place steel pin (pipe) piles and based on these results, provides the support for a modification to the presently used allowable axial pin-pile capacities.The intent of the load testing program was to determine how much influence the penetration resistance might have on the individual piles' ability to support the allowable axial load without undergoing any significant vertical deformation. For the purposes of this paper the ""allowable load capacity"" is considered to be the ultimate pile load capacity divided by a minimum factor of safety, typically considered to be 2.0 in this area. A pin (pipe) pile comprises an open or closed ended, schedule 80 steel tube which is driven-in-place, usually with an air compressor operated 90 pound pneumatic jack hammer. These jack hammers typically operate at a rate of about 1,200 blows per minute, (Haggard, Holtz and Mann, 2001 )."
Citation
APA:
(2005) Ultimate Bearing Capacity of Small-Diameter Pin-Piles and the Influence of Driving Penetration ResistanceMLA: Ultimate Bearing Capacity of Small-Diameter Pin-Piles and the Influence of Driving Penetration Resistance. Deep Foundations Institute, 2005.