Search Documents
Search Again
Search Again
Refine Search
Refine Search
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
- 
                     A Case History On The Design, Construction, And Field Quality Control Of Cement Deep Soil Mixing A Case History On The Design, Construction, And Field Quality Control Of Cement Deep Soil MixingBy Suthan Pooranampillai This paper presents a case study of the use of single axis cement deep soil mixing (CDSM) to deal with static settlement and seismic stability of the foundation soils under a reinforced soil slope (RS 
- 
                     A Case History on the Design, Construction, and Field Quality Control of Cement Deep Soil Mixing A Case History on the Design, Construction, and Field Quality Control of Cement Deep Soil MixingBy Dominic Parmantier, Karen Dawson, Suthan Pooranampillai, Seungcheol Shin "This paper presents a case study of the use of single axis cement deep soil mixing (CDSM) to deal with static settlement and seismic stability of the foundation soils under a reinforced soil slope (R Jan 1, 2017 
- 
                     A Case History Studying On Displacement Controlling In Deep Excavation A Case History Studying On Displacement Controlling In Deep ExcavationBy Feng Yongxuan Anchored sheep pile is normally used in deep excavations, many of which only require stability in accordance with Terzaghi theory. In this paper, based on the experience, new lateral earth pressure me Jan 1, 1991 
- 
                     A Case History – Termination of Pile in Rock Based on Penetration Resistance for a Bridge across River Mandovi in Goa A Case History – Termination of Pile in Rock Based on Penetration Resistance for a Bridge across River Mandovi in GoaBy Akshay Sakhuja, M. S. Karthika, R. Vignesh "The bridge across River Mandovi in Goa is a cable stay bridge structure proposed parallel, along existing bridges for regulation and reduction of vehicular traffic; the entire bridge structure is sup Jan 1, 2015 
- 
                     A Case Study - Drilled Pier Foundations for a New Atlanta Stadium A Case Study - Drilled Pier Foundations for a New Atlanta StadiumBy Jean Wehbe, Daniel C. Brahana "This paper presents a case history of drilled pier construction for a new stadium in Atlanta, Georgia. The stadium structure is supported on several different foundation types, with the heaviest ""me Jan 1, 2017 
- 
                     A Case Study Describing The Use Of A Top Down Construction Sequence For A Three Level Basement Using A Diaphragm Wall And Cfa Foundation Piles A Case Study Describing The Use Of A Top Down Construction Sequence For A Three Level Basement Using A Diaphragm Wall And Cfa Foundation PilesBy Chris Leach, Lucie Spencer This case study describes the geotechnical aspects of the basement construction for a multi-storey, residential and hotel complex located in the newly developed Elizabeth Quay precinct in Perth, Weste Nov 1, 2022 
- 
                     A Case Study In Hand-Dug Caissons ? Synopsis A Case Study In Hand-Dug Caissons ? SynopsisCaissons hand dug to a depth of about 100 feet were used to underpin three important structures at an industrial site in the State of Utah. The caisson shafts extended through 30 to 40 feet of coarse, Jan 1, 2010 
- 
                     A Case Study Of A Vibratory Pile Installation Monitoring Of A Precast Prestressed Concrete Pile A Case Study Of A Vibratory Pile Installation Monitoring Of A Precast Prestressed Concrete PileBy K. Viking It's well known that conventional impact hammers, usually are the method to use in order to drive precast prestressed concrete piles. However sometimes the vibratory technique might be considered Jan 1, 2004 
- 
                     A Case Study Of Deep Shaft Excavation In River Channel Soil Deposit In Kolkata A Case Study Of Deep Shaft Excavation In River Channel Soil Deposit In KolkataBy Kaustuv Bhattacharya, Manish Kumar, Nirbhay Singh, Prodyot Kr. Ray, Praveen Soin This paper highlights salient features of an excavation 38 m (Length) by 10 m (Width) by 24 m (Depth) carried out in Central Kolkata. Secant pile wall (SPW) formed using a combination of alternating 1 Sep 1, 2022 
- 
                     A Case Study of Multichannel Analysis of Surface Waves (MASW) as a Tool to Characterize Unknown Foundations A Case Study of Multichannel Analysis of Surface Waves (MASW) as a Tool to Characterize Unknown FoundationsBy Joseph T. Coe, Siavash Mahvelati, Philip Asabere Characterization of existing foundations remains an important issue as foundation reuse and rehabilitation continue to garner increased attention. In the case of unknown foundations, geophysical and n Jan 1, 2016 
- 
                     A Case Study Of Passive Piles Failure In Open Excavation A Case Study Of Passive Piles Failure In Open ExcavationBy S. T. Kok This paper presents a case study in West Malaysia for passive piles failure in very soft marine clay in open excavation. In this particular case, the thickness of the very soft marine clay ranges from Jan 1, 2009 
- 
                     A Case Study of Wet Soil Mixing for Bearing Capacity Improvement in Turkey A Case Study of Wet Soil Mixing for Bearing Capacity Improvement in TurkeyBy Arash Maghsoudloo, Asli Can "Abstract This paper presents a ground improvement implementation case under a raft foundation of a local hospital. The selected ground improvement method is Wet Soil Mixing (WSM) technique. Soil mixi Jan 1, 2014 
- 
                     A Case Study on the Effects of Using Surcharge Fill as a Complement to Ground Improvement with Dry Deep Mixing A Case Study on the Effects of Using Surcharge Fill as a Complement to Ground Improvement with Dry Deep MixingBy Stefan Larsson, Sebastian Adevik, Sadek Baker, Razvan Ignat "Abstract Uncertain strength, deformation and flow properties in dry deep mixing columns often lead to conservative choices concerning design values where the design is regularly complemented with a s Jan 1, 2014 
- 
                     A Case Study On Underreamed Piles ? Synopsis A Case Study On Underreamed Piles ? SynopsisBy Rajesh Minda 160 numbers of double bulb underreamed piles were constructed based on the safe loads specified in IS code at Tripura. The pile load tests yielded a much lower capacity. A detailed investigation work Jan 1, 1996 
- 
                     A Case Study Supporting The Need For A Rational Method For Design And Installation Of Vibratory Driven Piles A Case Study Supporting The Need For A Rational Method For Design And Installation Of Vibratory Driven PilesBy Franklin M. Grynkewicz The subject of bearing pile performance installed by vibratory hammers has been a matter of increasing study and continued controversy. A recent case study from a major bridge replacement project is d Jan 1, 1991 
- 
                     A Case Study, Design Change from Spread Footing to Drilled Shafts A Case Study, Design Change from Spread Footing to Drilled ShaftsBy Drew M. Kurtz, Jeff L. Rai, Sara F. Frailey, Mohammad Ayub Iqbal "This paper presents the foundation changes made for a five-span bridge over the Lehigh River constructed as a design-build project. During excavation within the cofferdam at Pier 2 for the constructi Jan 1, 2016 
- 
                     A Collaborative Approach To The Design And Delivery Of The Most Heavily Loaded Piles Ever Constructed In The Uk A Collaborative Approach To The Design And Delivery Of The Most Heavily Loaded Piles Ever Constructed In The UkBy Morris J. D, Baldwin Z., Wiltcher P. M 21 Moorfields is an oversite development in central London spanning Moorgate tube station. It required the installation of both the highest loaded bearing piles and the highest top loaded static pile 
- 
                     A Combination of Jet Grouting and MPSP Grouting in Iskar River Cascade Hydropower Plant in Bulgaria A Combination of Jet Grouting and MPSP Grouting in Iskar River Cascade Hydropower Plant in BulgariaBy Massimo Poggio, Gabriele Balconi, Andrea M. R. Pettinaroli, Mario Ruggiero, Riccardo Castellanza Grouting technologies are ground treatment techniques used for modifying the behaviour of a mass of soil or rock by injecting a mixture. The sleeved port pipes (also called Tube A Manchette) are highl Jan 1, 2019 
- 
                     A Comparative Study on Behavior of Bucket Pile in Sand According to Installation Methods A Comparative Study on Behavior of Bucket Pile in Sand According to Installation MethodsBy Jinung Do, Sung-Ryul Kim, Juhyung Lee "Model tests have been performed to investigate the vertical, horizontal and cone tip resistances of bucket pile embedded in sand by different installation methods; suction force by pump and jacking f Jan 1, 2016 
- 
                     A Comparison Of Open Drilled Shafts To Temporarily Cased Drilled Shafts In Clay Soil A Comparison Of Open Drilled Shafts To Temporarily Cased Drilled Shafts In Clay SoilBy W. Tom Witherspoon Many Engineers are skeptical and cautious about skin friction factors for the portion of drilled piers where temporary casing is used. This has led Texas engineers in many cases to eliminate skin fric Jan 1, 2009 
