Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Installing And Testing Multi-bar High Capacity Rock Tiedowns

    By Andrew Pontecorvo, Steven Lowe, David Sposito

    Buildings with large height-to-width ratios require foundations with significant uplift resistance. This paper presents a case study of the permanent rock tiedowns installed for One Manhattan West, a

  • DFI
    Design And Construction Of Micropiles Each Subject To 110 Kips Of Lateral Load

    By Andrew Baxter

    The Crystal Bridges Museum of American Art in Bentonville, Arkansas is a beautiful glass and concrete structure cut into a valley that mingles with water ponds spanned by multiple bridges with suspend

    Jan 1, 2008

  • DFI
    Piled Rafts In Geotechnical Practice - An International Perspective

    By Michael W. Neill, O&apos

    The performance of foundations that combine the high bearing capacity of rafts (mats) with the settlement reduction capability of piles is described through a summary of 24 case histories. Structures

    Jan 1, 2003

  • DFI
    Tension Tests On Driven Pipe Piles In Sand - Synopsis

    By Alan J. Lutenegger

    A series of tension tests were performed on prototype scale steel pipe piles at two sites to evaluate the influence of scale and pile plugging on the unit skin friction developed in axial tension. The

    Jan 1, 2000

  • DFI
    Uncertainties Arising During Drilling And Performance Of Flight Auger - Cast Piles

    By F. M. Abdrabbo

    Flight auger bored piles are formed by screwing a continuous flight auger into the ground, and pumping cement/sand grout or concrete down the hollow stem of the auger as its withdrawn. The auger is dr

    Jan 1, 1993

  • DFI
    Dynamic Testing Of Model Piles - A Laboratory Study - Synopsis

    By P. Srinivasulu

    The popular theoretical models used for assessing the dynamic behaviour of piles under vertical and lateral excitations are critically reviewed. An experimental study is presented on model piles with

    Jan 1, 1996

  • DFI
    Session 15 "Jet Grouting IV"

    By Mitsuhiro Shibazki

    I can't answer that question but I am looking at Andy, my co-author, and he says we didn't measure it. No movement. If I understand it correctly, how do we handle lateral forces in shear? T

    Feb 10, 2003

  • DFI
    Studies On Pile Driving Cushion Materials ? Synopsis

    By H. R. Shen

    Cushion materials are one of the most important links in an efficient piling system. In the past, little has been done in China on this problem, so engineers are still used to those traditional woods,

    Jan 1, 2010

  • DFI
    Interpreting Strain Measurements From Load Tests In Bored Piles

    By Jack Hayes

    Vibrating wire strain gages have proven to be a very reliable and effective tool for the measurement of strains associated with the loading of bored piles (drilled shafts). However, when these strains

    Jan 1, 2002

  • DFI
    Foundation Code8 And Linit 8tatb Partial Factoring - Synopsis

    By W. G. K. Fleming

    The codification of foundation design and construction is a subject of extensive discussion in Europe and all current code proposals are based on limit state partial factoring. For simplicity, it is c

    Jan 1, 1996

  • DFI
    Behavior Of Friction Piles In Soft Clays

    By Safwan Labanieh

    An experimental set-up is specially designed to study the behavior of a friction pile of 3 cm diameter in contact with the soft clay of Mexico City in a small calibration chamber (CC) of 30 cm diamete

    Jan 1, 2002

  • DFI
    Capacity Prediction Vs. Performance Of Driven Pre-Cast Pre-Stressed Concrete Piles In Chesapeake, Virginia

    By Emad Farouz

    This paper compares the predicted axial capacity of driven Pre-cast Pre-stressed Concrete (PPC) piles for the Lake Gaston Water Treatment Plant (LGWTP) using several design methodologies versus the ax

    Jan 1, 2007

  • DFI
    Vibrodriving And The Compaction Of Granular Soils

    By RAP Bement

    Installation by vibrodrivers of sheet and bearing piles generates periodic vibrations in the surrounding ground, which have been widely measured and reported. One of the possible consequential effects

    Jan 1, 1996

  • DFI
    Piled Raft System - Approximate Design Methods. - Synopsis

    By S. L. Karunakaran

    There are cases where it is found that a raft foundation would have adequate factor of safety against ultimate bearing capacity failure but the settlements would be excessive. Piles may be introduced

    Jan 1, 1996

  • DFI
    Effects Of Environment On Deep Foundation Elements - Synopsis

    By Subhash B. Bhide

    Deep foundations are affected by the presence of sulphates, chlorides, organic contents and water currents present in the soil. The sulphates in soil and ground water interfere first with setting of c

    Jan 1, 1996

  • DFI
    Safe Load Of A Single Pile In Earthquake Loading - Synopsis

    By Shamsher Prakash

    Estimation of vertical load carrying capacity of a single vertical pile under earthquake loading is an important task of a design engineer. Lateral vibration of vertical pile is highly influenced by t

    Jan 1, 1996

  • DFI
    The Realities Of Resolving Conflicts During Construction ? Synopsis

    By J. S. Ward

    In a well-written set of contract documents, the probability of conflicts arising during the course of construction is minimized. However, no matter how complete may be the technical language in the c

    Jan 1, 2010

  • DFI
    Cone Penetration Testing Can Save Money (and Trouble)

    By Rob van Dorp

    Most traditional foundation designs are based on soil investigations using Standard Penetration Testing (SPT), sometimes combined with static load testing on sacrificial trial piles. However, this des

    May 1, 2022

  • DFI
    Relevance Of Ryznar Index In Under Water Concrete - Synopsis

    By V. T. Ganpule

    The effect of Sulphate and Chloride is well understood by the engineers. Most of the codes stipulate permissible limits for sulphate and chloride content in groundwater. Relatively few reference are a

    Jan 1, 1996

  • DFI
    Ground Improvement Resulting From Installation Of Drilled Displacement Piles

    By Timothy C. Siegel

    Drilled displacement piles (also known as augered cast-in-place displacement piles or augured, pressure grouted displacement piles) are installed by the displacement of soil and subsequent placement o

    Jan 1, 2007