Search Documents
Search Again
Search Again
Refine Search
Refine Search
- 
                     High Capacity Hollow Core Bar Piles High Capacity Hollow Core Bar PilesBy Lawrence F. Johnsen, Felix Ferrer, Dino Tomasetti, Cassandra A. Wetzel "A 17 story building was constructed at the Brooklyn Navy Yard on a site with a long history of development. Most recently the site supported a dewatering well and craneway to service two adjacent dry Jan 1, 2017 
- 
                     Grouted Micropiles for Foundation Remediation in Expansive Soil (8th Michael W. O?Neill Lecture) Grouted Micropiles for Foundation Remediation in Expansive Soil (8th Michael W. O?Neill Lecture)By John D. Nelson Foundation underpinning is a common component of remediation schemes for distressed foundations on expansive soils. For many applications in expansive soil, micropiles have distinct advantages over ot Aug 1, 2013 
- 
                     Pile Design Philosophies For Coralline And Weak Carbonate Rocks Pile Design Philosophies For Coralline And Weak Carbonate RocksBy Rahul Wankhade, Sunil S. Baswankar, Aditya S. Kharatkar Despite advances in pile design methodologies and piling techniques at site, difficulties and uncertainties still exists for design of piles particularly in coralline deposits and weak carbonate rocks Sep 1, 2022 
- 
                     Shoring of Long Beach Main Pump Station Utilizing Ground Improvement Methods, Long Beach, CA Shoring of Long Beach Main Pump Station Utilizing Ground Improvement Methods, Long Beach, CABy Eric Lindquist, John Compagnone, Gabriel Carvajal "Condon-Johnson & Associates, Inc. (CJA) with the assistance of design consultant, Brierley Associates, designed and installed a water tight shoring system utilizing several ground improvement techniq Jan 1, 2017 
- 
                     Wet Soil Mixing For Foundation Support and Liquefaction Hazard Mitigation for the Ventura Cancer Center Wet Soil Mixing For Foundation Support and Liquefaction Hazard Mitigation for the Ventura Cancer CenterBy Thang V. Nguyen, Lisheng Shao, Gary E. Taylor "The Community Memorial Hospital of Ventura, California, proposed to build a new state-of-the-art Cancer Treatment Center with radiation shielding walls and roof. The loose silty soils at the site had Jan 1, 2015 
- 
                     Replacement of the Kosciuszko Bridge Brooklyn Connector: An Integrated Design and Construction Approach Replacement of the Kosciuszko Bridge Brooklyn Connector: An Integrated Design and Construction ApproachBy M. D. Riegel, P. B. Pizzimenti, E. M. Zamiskie, Britain A. Materek "The Skanska/Kiewit/ECCO III team (SKE) in association with HNTB was awarded the design-build contract for Phase I of the Kosciuszko Bridge Replacement Project. As lead designer for the SKE team, HNTB Jan 1, 2016 
- 
                     Assessment of Existing Bulkhead Walls for Dredging Impacts Assessment of Existing Bulkhead Walls for Dredging ImpactsBy Rakam Lama Tamang, Michael J. Byle, Stephen Ernst "For various reasons, dredging may become necessary in front of existing bulkhead walls, either for channel deepening or for environmental remediation of contaminated sediments. The removal of sedimen Jan 1, 2017 
- 
                     Cyclic Degradation on Wind Turbine Foundations in Cohesive Soils Cyclic Degradation on Wind Turbine Foundations in Cohesive SoilsBy Yazen Khasawneh, Osvaldo P. M. Vitali, Mohammad Nassim Wind turbines are subjected to complex form of cyclic loadings with variable amplitudes and frequencies. The cyclic loading and the accumulation of plastic strains with the number of cycles will resu Sep 8, 2021 
- 
                     Safety Evaluation Of Adjoining Structures In Urban Areas During Deep Excavation: A Case Study Of Nagpur Metro Safety Evaluation Of Adjoining Structures In Urban Areas During Deep Excavation: A Case Study Of Nagpur MetroBy Shreya Vivek Hokam, Dr. A. I. Dhatrak, S. W. Thakare, Dr. Vivek S. Hokam Construction in congested urban areas has necessitated tall and massive structures. In urban areas, it is common to construct underground structure nearby existing buildings. Selection of an appropria Sep 1, 2022 
- 
                     Jardim de Alah Station — Built in Olympic Time Jardim de Alah Station — Built in Olympic TimeBy Dario Libano, Luis Carlos Tenuta, Juliano Penteado "Subway Line Number 4 is one of the newest additions to the Rio de Janeiro subway network. Built for the 2016 Olympic Games, the 16 km (10 mi) subway line connects the south of the city, with the famo Jan 1, 2016 
- 
                     Analysis of Three Axial Load Tests on Large Bored Grouted Deep Foundations Analysis of Three Axial Load Tests on Large Bored Grouted Deep FoundationsBy Hayel M. El-Naggar, Marawan M. Shahien "Large capacity piles are important type of foundation elements that are needed in case of high column loads such as in tall buildings with large span between columns. In many projects, especially if Jan 1, 2017 
- 
                     Time-Dependent Increase Of The Bearing Capacity Of Displacement Piles Time-Dependent Increase Of The Bearing Capacity Of Displacement PilesBy Florian König It is well known that the bearing capacity and stiffness of displacement piles may increase significantly with time, a phenomenon usually referred to as set-up. In cohesive soils the set-up is commonl Jan 1, 2006 
- 
                     Cofferdam Failures ? Introduction Cofferdam Failures ? IntroductionBy Richard J. Hartman This presentation identifies some of the more common problems associated with cofferdam construction. After the various problems are identified, they are briefly explained and possible solutions and p Jan 1, 1987 
- 
                     Augered Pile World Record Depth within a Soil Mix Basement Augered Pile World Record Depth within a Soil Mix BasementBy Andres M. Baquerizo, Jeremiah J. Filjones, Nicholas Feldt The Estates at Acqualina located in Sunny Isles Beach, FL, is comprised of two, ocean-front, 50-story, luxury towers with podiums and villas. With city regulations now requesting that above-grade floo Jan 1, 2019 
- 
                     Large Diameter Open-End Pipe Pile Driveability Analysis Including Geotechnical Friction Fatigue Large Diameter Open-End Pipe Pile Driveability Analysis Including Geotechnical Friction FatigueBy Patrick J. Hannigan, Frank Rausche, Rozbeh B. Moghaddam Large diameter open-end pipe piles are increasingly used as deep foundations to support heavy onshore and offshore structures. During the driving process, several factors such as subsurface conditions Jan 1, 2019 
- 
                     Willow Island Hydroelectric Project: Taming the Ohio River to Create Green Energy Willow Island Hydroelectric Project: Taming the Ohio River to Create Green EnergyBy James M. Tantalla, Jr. Ellman "Construction of the powerhouse for the Willow Island Hydroelectric Project, located at the Willow Island Lock and Dam, required a 120-ft deep temporary excavation inside the limits of a cellular coff Jan 1, 2016 
- 
                     Use of Isolated Tie-Back Plates to Stabilize a Landslide in Steep Terrain Use of Isolated Tie-Back Plates to Stabilize a Landslide in Steep TerrainBy Scott D. Neely, Donald R. Clark "An existing landslide located at the southeast corner of the Telluride Regional Airport has been in an active state of failure for several years. The presence of the landslide has represented an on-g Jan 1, 2015 
- 
                     An In-Situ Model Test For A Large Hydraulic Press Foundation ? Synopsis An In-Situ Model Test For A Large Hydraulic Press Foundation ? SynopsisBy R. J. Yan There was a plant equipped with a 32000t Hydraulic Press to be built, under which a box foundation of 22.5m x 15m x 14.25m (depth) with a base slab of, varying thickness was proposed. The subgrade rea Jan 1, 2010 
- 
                     Effects Of Permanent And Temporary Loads On Allowable Bearing Capacity Of Piles Subjected To Nagative Skin Friction Effects Of Permanent And Temporary Loads On Allowable Bearing Capacity Of Piles Subjected To Nagative Skin FrictionBy Mohammad T. Izadi Piles are, often, used for transferring load from the super structure through soft consolidating strata onto relatively stiff uncompressible soils. Downward movement of the soft soil strata develops Jan 1, 2001 
- 
                     Laboratory Mixing and Testing for Controlled Waste Disposal Site Laboratory Mixing and Testing for Controlled Waste Disposal SiteBy Tomohiro Yamasaki "At the pre-construction foundations of the controlled waste disposal site built at the Port of Kinuura, the clayey soil account for the most, and with lesser amounts of sand compaction piles and sand Jan 1, 2015 
