There was a plant equipped with a 32000t Hydraulic Press to be built, under which a box foundation of 22.5m x 15m x 14.25m (depth) with a base slab of, varying thickness was proposed. The subgrade reactions, bending moments and settlements needed to be determined by means of in-situ model test. A model of the same materials as the prototype scaled to l/10 was embedded in-situ with simulated depth in the bedrock. A lot of data obtained from 39 bench marks, 32 elongation measuring points, 30 couples of electric resistance strain gauges and 24 pressure cells attached to the model foundation enables all the quantities required to be found out. Since it was put into operation, the settlements measured has reasonably agreed with the test results and the foundation has been in good condition.