Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Rock Socket Piles In The Sherwood Sandstone Of Central Birmingham

    By L. J. Whitworth

    Five trial piles were constructed during the trial pile programme for the Birmingham International Convention Centre. In addition, trial piles have been tested on two other sites in central Birmingham

    Jan 1, 1989

  • DFI
    Studies On Pile Driving Cushion Materials ? Synopsis

    By H. R. Shen

    Cushion materials are one of the most important links in an efficient piling system. In the past, little has been done in China on this problem, so engineers are still used to those traditional woods,

    Jan 1, 2010

  • DFI
    Interpreting Strain Measurements From Load Tests In Bored Piles

    By Jack Hayes

    Vibrating wire strain gages have proven to be a very reliable and effective tool for the measurement of strains associated with the loading of bored piles (drilled shafts). However, when these strains

    Jan 1, 2002

  • DFI
    Developments In Coatings To Combat Negative Skin Friction - Bitumen Coatings: Practical Design And Construction Aspects

    By George Machan

    Bitumen coatings have been successfully used to significantly reduce downdrag on piles. Thicker coatings of "soft" bitumens can accommodate downdrag so well that very little downdrag load is transferr

    Jan 1, 1989

  • DFI
    Parametric Analysis Of Piled Rafts Founded On A Tropical Clay Of Brazil

    By Renato P. Cunha

    The paper presents the results of a comparative and parametric analysis in which a numerical program developed exclusively for groups of deep foundations under general loading (vertical, horizontal an

    Jan 1, 2002

  • DFI
    Design And Analysis Of Cooling Tower Pile Foundations

    By Michael W. Oakland

    This paper summarizes the analysis and design of a pile foundation system for two 400 ft. diameter, 500 ft. high cooling tower using a detailed finite element analysis package. The cooling towers are

    Jan 1, 2010

  • DFI
    Analysis On The Vertical Bearing Capacity Of Socketed Piles

    By Yong Jingrong

    Based on the results of several test socketed piles in Sichuan, the mechanism of the deformation for a loaded socketed piles is investigated, and the concept of the socketed effect is proposed. The be

    Jan 1, 1991

  • DFI
    A Seismic Construction Of Piling Head ? Synopsis

    By K. Oshima

    In Japan, earthquakes are experienced frequently. Many buildings and structures in Japan are supported on pile foundations. For these pile foundations, the joint section between the piles and footing

    Jan 1, 2010

  • DFI
    Laboratory Validation Of In-Situ Tests - 1. Introduction

    This paper summarizes seven years of Italian ex­perience with the use of large calibration chambers for the calibration, under closely controlled stress and strain conditions, of some in situ testing

    Jan 1, 1987

  • DFI
    DFI Model Piledriving Contractor Proposal

    With respect to liability damages, claims and costs thereof relating to or ansmg out of contamination, special or non-special wastes, hazardous wastes or pollution in connection with the performance o

  • DFI
    Vibrodriving And The Compaction Of Granular Soils

    By RAP Bement

    Installation by vibrodrivers of sheet and bearing piles generates periodic vibrations in the surrounding ground, which have been widely measured and reported. One of the possible consequential effects

    Jan 1, 1996

  • DFI
    Seven Mile Dam Retrofit - A Global Challenge

    By Arvindh Gupta

    BC Hydro proposed to improve the stability of the existing Seven Mile Dam with 54 corrosion protected, re-stressable anchors comprising 92/0.6? strands each, in phase 2 of the program. Being globally

    Jan 1, 2004

  • DFI
    Micropiles In Soft Florida Limestone

    By James D. Hussin

    The Florida limestone is a relatively soft rock which presents many challenges to engineers when designing deep foundations. One alternative is micropiles which have grown significantly from their ear

    Jan 1, 2003

  • DFI
    JFKIA - Post Grouted Drilled Shafts And Driven Piles - Update - Synopsis

    By Walter G. Brusey

    This paper describes a comprehensive pile test program conducted at John F. Kennedy International Airport (JFKIA) to evaluate pile types and design capacities ranging from 890 to 4450 KN (100 to 500 t

    Jan 1, 2000

  • DFI
    Cone Penetration Testing Can Save Money (and Trouble)

    By Rob van Dorp

    Most traditional foundation designs are based on soil investigations using Standard Penetration Testing (SPT), sometimes combined with static load testing on sacrificial trial piles. However, this des

    May 1, 2022

  • DFI
    Relevance Of Ryznar Index In Under Water Concrete - Synopsis

    By V. T. Ganpule

    The effect of Sulphate and Chloride is well understood by the engineers. Most of the codes stipulate permissible limits for sulphate and chloride content in groundwater. Relatively few reference are a

    Jan 1, 1996

  • DFI
    Foundation Code8 And Linit 8tatb Partial Factoring - Synopsis

    By W. G. K. Fleming

    The codification of foundation design and construction is a subject of extensive discussion in Europe and all current code proposals are based on limit state partial factoring. For simplicity, it is c

    Jan 1, 1996

  • DFI
    Drilled Piers Support Massive Gantry Crane

    By John R. Davie

    This paper describes the design and construction of two 5.6 MN capacity drilled piers installed to support the main loading elements of a large cantilevered gantry crane. The critical crane columns we

    Jan 1, 2006

  • DFI
    Soil Improvement in Marina Coastal Expressway Project (C485) with Cement Deep Mixing (CDM) Method

    By Yoshinori Kurumada, Tatsuo Nagatsu, Keiji Uchida

    "Cement deep mixing method has been utilized in the process of construction of an underwater tunnel in Singapore. The soil was improved by this method to prevent undesirable heaving of the soil below

    Jan 1, 2015

  • DFI
    Piled Raft System - Approximate Design Methods. - Synopsis

    By S. L. Karunakaran

    There are cases where it is found that a raft foundation would have adequate factor of safety against ultimate bearing capacity failure but the settlements would be excessive. Piles may be introduced