Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Design And Construction Of The Rion Antirion Bridge Foundations

    By Alain Pecker

    The choice of a design concept for a bridge foundation is guided by various factors; several of these factors are indeed of technical origin, like the environmental conditions in a broad sense, but ot

    Jan 1, 2013

  • DFI
    The Behavior And Design Of Piled-Raft Foundations Under Lateral Loading

    By Serge Borel

    An efficient design method is proposed for "piled-footing" and "piled-raft" foundation under lateral loads. It combines the methods used for the displacement design of shallow and deep foundations and

    Jan 1, 2002

  • DFI
    Pile Driving Hammers In Centrifuge Modelling - Synopsis

    By Daniel Levacher

    Pile load tests in site require extensive means of action and time. To get outstanding tests, the environmental test conditions must be perfectly known and acceptable. They concern the support install

    Jan 1, 1996

  • DFI
    Axial Pile Response Evaluation By Geophysical Piezocone Tests

    By Paul W. Mayne

    The axial load-displacement-capacity and load-transfer response of deep foundations can be conveniently assessed by geophysical piezocone tests that provide four independent readings with depth, inclu

    Jan 1, 2002

  • DFI
    Innovation In South East Asia - Synopsis

    By Brian Littlechild

    Whilst there is much innovative work being undertaken in South East Asia in the space allowed in this paper we have settled on describing in more detail the work that has been done with shaft grouting

    Jan 1, 2000

  • DFI
    Innovations In Diaphragm-Wall Construction Plant

    By Maurice Guillaud

    The most striking innovations on diaphragm-wall construction plant are those associated with continuous real-time trajectory monitoring of the excavating tool (either a grab or a hydro-cutter). Th

    Jan 1, 2002

  • DFI
    The Monroe St. Viaduct: A Case History Of MSE Vibro-Concrete Column Supported Embankment

    By Paul J. Lewis

    Replacement of the Monroe Street Viaduct in southwest Baltimore City, Maryland included transforming 240 feet of the south approach from a pile-supported multi-span bridge to a mechanically stabilized

    Jan 1, 2007

  • DFI
    Diameter Effects On p-y Curves

    By Ignatius P. O. Lam

    This paper presents information on design analyses of large diameter piles using conventional p-y curves as recommended by the American Petroleum Institute (API RP2A, 1993). API RP2A adopted the soft

    Jan 1, 2013

  • DFI
    Innovative European Technologies To Accelerate Construction Of Embankment Foundations - Part II: DM, FMI, Mass Stabilization & CSV

    By Ali Porbaha

    In today's fast-track construction environment, owners are searching for non-conventional technologies to build their projects faster and safer while maintaining traffic flow during construction.

    Jan 1, 2002

  • DFI
    Osterberg Cell Tests Confirm In-Situ Pier Capacity In Colorado - Introduction

    By William Siegel

    Kleinfelder provided foundation analysis and design for an expansion to a cement plant in Florence, Colorado. The expansion was a conversion from a horizontal wet process to a vertical dry process, a

    Jan 1, 2007

  • DFI
    Dynamic Characterization Of Drilled Shafts On Doremus Avenue Bridge

    By Martina Balic

    Dynamic properties of the drilled shaft foundations supporting Doremus Avenue Bridge were determined by forced vibration testing. The main objectives of the substructure testing at Doremus Avenue Brid

    Jan 1, 2004

  • DFI
    Hybrid Energy System Installed on Deep Mixing Barge

    By Kento Miyamoto, Kazuki Imamura, Takayuki Tanaka

    "Global economic development has drastically increased energy consumption in various fields, and CO2 emissions, which are a prime cause of global warming, have continued to increase. Therefore, measur

    Jan 1, 2015

  • DFI
    Experimental And Numerical Assessment Of Osterberg Load Tests On Large Bored Piles In Sand

    By Roberto Nova

    The selection of the Osterberg Cell (O-Cell) technology as the standard testing method for deep foundations of the Railways Po Viaduct in Northern Italy offered a relevant number of field measures on

    Jan 1, 2008

  • DFI
    Design, Construction And Testing Of Micro-Piles Used To Support A Concrete Arch Bridge

    By William Auyeung

    Micro-piles are small-diameter, drilled and grouted reinforced piles used for both structural support and in situ earth reinforcement. They were conceived in Italy in 1952, but have become popular in

    Jan 1, 2004

  • DFI
    Comparison of 2D and 3D Anchor Analysis Methodologies

    By Ruth McKeown, Gilson de F. N. Gitirana, Murray Fredlund, HaiHua Lu

    The current design standards for the use of anchors in slopes is based on two-dimensional (2D) limit equilibrium analyses. Anchors are considered as discrete loads and the 2D anchor, factored based on

    Jan 1, 2019

  • DFI
    Use Of Installation Effort To Evaluate And Design Drilled Displacement Piles In Fine-Grained Soils

    By W. Morgan NeSmith

    A drilled displacement pile program was utilized for the expansion of an existing power plant in Cohasset MN adjacent to the Mississippi River. The drilled displacement (DD) pile is an innovative foun

    Jan 1, 2008

  • DFI
    The Stability Of A Diaphragm Wall ? Synopsis

    By X. L. Chen

    The diaphragm walling has been recently adopted in one of the largest excavation of deep foundation engineerings in Shanghai, China with dimension of 90m in length, 50m in width and 13m in depth to so

    Jan 1, 2010

  • DFI
    High Strain Testing Of Large Diameter, High Capacity Unlined Bored Piles ? Introduction

    By Dhanvin B. Mehta

    Pile testing is generally understood as static load test. It is our common experience that for high capacity, large diameter bored piles, static testing is expensive and time consuming. It is practica

    Jan 1, 1996

  • DFI
    Seven Mile Dam Retrofit - A Global Challenge

    By Arvindh Gupta

    BC Hydro proposed to improve the stability of the existing Seven Mile Dam with 54 corrosion protected, re-stressable anchors comprising 92/0.6? strands each, in phase 2 of the program. Being globally

    Jan 1, 2004

  • DFI
    Behaviour Of Laterally-Loaded Piles Centrifugal And Numerical Modelling ? Synopsis

    By W. H. Craig

    Techniques have been developed for installing model piles into beds of soil under high sustained acceleration levels aboard a centrifuge. These piles have been subjected to static and/or cyclic latera

    Jan 1, 2010