Bi-Directional Load Testing Of A Pile Bored Using Bentonite Mud In Guinea Bissau
By Frédéric Rocher-Lacoste
On July 2nd, 2007, LCPC and LOADTEST performed a static loading test with an Osterberg-cell on a bored pile of 1600 mm diameter. The 56.50 meters deep test pile constructed by Trevi Spa for Soares da
Jan 1, 2008
-
The Design of Partial Depth Cement Deep Mixing (CDM) Foundation for an Immersed Tunnel
By J. S. Lee, R. K. Massarsch
"A 3.2 km long immersed road tunnel forms part of the Busan-Geoje Fixed Link in South Korea, which connects Korea's second largest city Busan, with the island of Geoje. To ensure the water tightness o
Jan 1, 2015
-
Geophysical Subsurface Characterization to Estimate Top-Of-Rock Elevation for Deep Foundations in Challenging Geologic Settings: Numerical Investigation of Full Waveform Tomography
By Siavash Mahvelati, Alireza Kordjazi, Joseph Thomas Coe
Deep foundations are often constructed as end bearing members with a significant amount of their capacity derived from bedrock. Sites with highly variable bedrock conditions therefore present a uniq
Sep 8, 2021
-
Geophysical Subsurface Characterization To Estimate Top-Ofrock Elevation For Deep Foundations In Challenging Geologic Settings: Numerical Investigation Of Full Waveform Tomography
By Siavash Mahvelati, Alireza Kordjazi, Joseph Thomas Coe
Deep foundations are often constructed as end bearing members with a significant amount of their capacity derived from bedrock. Sites with highly variable bedrock conditions therefore present a unique
Oct 1, 2021
-
8000 Series Piling Rig
By Roger A. Bullivant
The introduction of this size and type of piling rig is intended to address a multipurpose foundation activity. The 8000 denotes the size of equipment that is attached to the mast, namely 8000 Kg. Lar
Jan 1, 1995
-
120 Years of Caisson Foundations in Chicago
By Robert E. Schock, Eric J. Risberg
"Less than 20,000 years ago, the last of the glaciers retreated from the Chicago region. They left behind sheets of glacial clay till underlain by dense, over-consolidated till (“hardpan”) below which
Jan 1, 2016
-
Selecting the Right Shoring System – San Francisco Experience
By Heinrich Majewski, Rob Jameson
"Careful review of site conditions and constraints is essential to select the appropriate shoring system for each project. Key evaluation criteria include the geotechnical profile, groundwater and env
Jan 1, 2017
-
Dynamic Response of Short Piles under Lateral Transient Load
By Ambarish Ghosh, Rituparna Dey, Indrajit Chowdhury
"In port and harbor facilities, jetties and cargo berth terminals are usually installed on piles that remain partially embedded in soil, while a part of it behaves as columns supporting top deck. Tech
Jan 1, 2015
-
Refurbishment Of A Piled Commercial Building With A Single Level Basement For A 70% Increase In Floor Area
By Henry H. Tayler, Eric Sturel
1 Triton Square was originally a six-storey building with a one-level basement located within a commercial development near Euston, London. It was designed and constructed in the 1990s and the foundat
May 1, 2022
-
Metro Sports Facility – A Ground Improvement Case Study
By I. D. McPherson, Dominic P. Mahoney
The Metro Sports Facility is currently under development in Christchurch, New Zealand and is a key Anchor Project in the city’s post-earth quake recovery. When completed it will be largest indoor spor
Nov 1, 2022
-
Slurry Wall Design for Construction Using Soil Structure Interaction
By Nino Catalano, Meeok Kim, Gordon Chen
"The design of the below grade structure of Brigham Building for the Future (BBF) included three different areas to provide power generation and medical facilities as well as a parking garage. The thr
Jan 1, 2017
-
Automation Of Pile Foundation Design Post-Processing To Produce Pile Plans
By Rajasekar Subbian, Jessica Oudhof
In the Netherlands pile foundation design is done using CPTs in accordance with EC7 national annexure. The capacity per tip level is calculated for every CPT followed by zonation to find the tip level
May 1, 2022
-
Murphy's Law And The Pile Prediction Event At The 2002 ASCE GeoInstitute's Deep Foundations Conference
By Bengt H. Fetlenius
The "Pile Prediction Event" at the ASCE GeoInstitute's Deep Foundation Conference in February 2002 involved prediction of drivability and capacity of three 14m long, 324mm diameter, closed-toe pi
Jan 1, 2004
-
Oldie But Goldie – Bi-Directionally Tested Foundation Piles With Base Enlargement As A Smart And Economical Alternative To Conventional Piles At Geneva, Switzerland
By Dipl. -Ing. (FH) Thomas Schmitt, Dr. Melvin England
Foundations in Geneva are difficult and expensive due a large overlayer of clay and silt above competent bearing material in the moraine. Common foundation schemes use deep barrettes or bored piles, f
May 1, 2022
-
Hybrid Design Approach for Anchored Retaining Walls in Complex Geology
By Christopher J. Ramsey, Don W. Dotson
"An existing four lane section of US 27 was widened to eight lanes. The project lies in the rugged Valley and Ridge Province of the Appalachian mountains starting at the Tennessee River in Chattanooga
Jan 1, 2015
-
An Unique Formula for the Stone-Column Group Efficiency
By Abhijit Saha
"The stone columns improve the performance of foundations on soft and loose soil due to the ability of composite ground to sustain increased structural loads under reduced settlements. The interaction
Jan 1, 2015
-
“Value Engineering” — Four Case Histories
By Maral Papazian Bedian
"Case 2. 100th Street Bus Depot: Elimination of Deep Caissons in Favor of Spread FootingsThe PROJECTThe 100th Street Bus Depot is a new five-story bus terminal for the New York City Metropolitan Trans
Jan 1, 2003
-
A Study On Performance Of Piles Based On Methods Of Installation
By Babu K. V., Samyukta P.
The energy demand in India is expected to show increasing growth in the next few decades. The oil companies in India are revamping the existing oil refineries as well as constructing new refineries ac
Sep 1, 2022
-
Self-Hardening Slurry Wall Installation by Hydromill at the Herbert Hoover Dike – An Innovative Solution (05e83755-4ec2-4ed4-a26c-d1e81c41960c)
By Mario Mauro, Jeff Taylor, Carlos Morales
"In 2007 the US Army Corps of Engineers classified the Herbert Hoover Dike in Florida as a Dam Safety Action Classification (DSAC) 1 dam, and started the implementation of one of the largest dam rehab
Jan 1, 2017
-
Mansueto Library: Drama below Ground and Above
By Patrick J. Lydon, Gregory A. Terri
"The recently opened Mansueto Library at the University of Chicago campus was a 2012 OPA runner-up. The dramatic elliptical shaped dome of this structure tells only part of this structure’s story. The