    Keynote Lecture 2: Dr. Masaaki Terashi The State of Practice in Deep Mixing Methods

    By Masaaki Terashi

    The machine for the hybrid method called JACSMAN is ordinarily a dual shaft machine. Each shaft has augers at three different levels and nozzles for jetting at two different levels. The distance betwe

    Feb 10, 2003

  • DFI
    Verification of Installation and Performance of ACIP Piles for Bridges

    By W. Morgan NeSmith

    "The DFI ACIP Pile Committee, in conjunction with the Florida DOT, completed an ACIP Pile installation monitoring and performance test program in late 2016 to advance the inclusion of ACIP piles in fu

    Jan 1, 2017

  • DFI
    Numerical Analysis of Progressive Failure of DM Columns beneath Embankment on Soft Ground

    By Zhou Haizuo, Diao Yu, Zheng Gang

    "The conventional design method for the embankment supported by DM columns usually assumes the simultaneous failure of all the columns. However, the progressive failure may occur in practice, especial

    Jan 1, 2015

  • DFI
    Indicator Pile Program at Port of Oakland, California

    By Partha Sircar

    "For Berth 22 modifications at the Port of Oakland, nearly 600 octagonal 24-inch ‘diameter’ precast-prestressed concrete piles were driven, some piles over 160 feet long. Prior to production pile driv

    Jan 1, 2015

  • DFI
    A Review of the Design Formulations for Static Axial Response of Deep Foundations from Cone Penetration Test Data

    By Fawad S. Niazi

    Analysis of deep foundations in terms of axial capacity has been a topic of great interest in the soil-structure interaction problems. Soil behavior is governed by a series of complex stress-strain ch

    Jan 1, 2013

  • DFI
    Geophysical Methods For Site Characterization For Marine Foundations

    By Richard E. Sylwester

    Evaluating surface and subsurface conditions for marine foundations (bridges, causeways, terminals, etc.) is often done with a limited amount of data. Subsurface information for these projects is pri

    Jan 1, 2013

  • DFI
    Analysis of Load Transfer along Large Diameter Bored Piles in Very Dense Sands

    By Nabil F. Ismael, Khalid Farraj

    "The axial load transfer along large diameter bored piles in very dense silty sand was examined by field tests. Two instrumented piles 1.2 m diameter and with embedded length of 18 m and 25 m were loa

    Jan 1, 2017

  • DFI
    Application of Non-Destructive Testing to Drilled Shafts

    Technically speaking, the concept of NDT sounds like the "magic bullet" when faced with a questionable drilled shaft. All the Contractor or Engineer needs to do is select an NDT method, apply it, unde

    Jan 1, 2004

  • DFI
    Using Settlement-Control Piles To Enhance Mat Foundation Of A High-Rise Building In Orlando

    By Amr M. Sallam

    A case history of utilizing a mat foundation enhanced with ?settlement-control? piles to support a high-rise building in Downtown Orlando is presented. Original geotechnical engineering studies, perf

    Jan 1, 2009

  • DFI
    Building a High-Rise Adjacent to Transit Tunnels in San Francisco (6bdbc52a-94a2-4c48-ba21-cc4450dc649d)

    By Lori A. Simpson, Linda H. Liang

    A high-rise building, consisting of two tower structures occupying the entire site, is in construction in San Francisco. The North Tower will consist of 12 and 35 stories above a one-level basement. T

    Jan 1, 2017

  • DFI
    Building A High-Rise Adjacent To Transit Tunnels In San Francisco

    By Lori A. Simpson

    A high-rise building, consisting of two tower structures occupying the entire site, is in construction in San Francisco. The North Tower will consist of 12 and 35 stories above a one-level basement.

  • DFI
    Numerical Modeling Of Foundation Deformation Due To Fault Rupture

    By Amalia Giannakou

    When designing structures in seismically active areas, foundations of critical structures are typically located away from known faults. Indeed many seismic codes prohibit construction in the immediate

  • DFI
    Analysis of Soil and Structural Thermal Response of a Field Scale Geothermal Energy Pile

    By Mohammed Faizal, Abdelmalek Bouazza

    "The operation of ground source heat pumps combined with foundation piles can have an effect on the thermal behaviour of the pile and the surrounding soil. This paper presents the effects of continuou

    Jan 1, 1900

  • DFI
    Numerical Modeling of Foundation Deformation Due to Fault Rupture (718b3bb2-ba73-41ae-ad4b-2a32fb89742b)

    By Orestis Zarzouras, Amalia Giannakou, Jacob Chacko

    "When designing structures in seismically active areas, foundations of critical structures are typically located away from known faults. Indeed many seismic codes prohibit construction in the immediat

    Jan 1, 2017

  • DFI
    Study on a Method for Determining the Proper Cover Soil Depth for Cement Ground Improvement in Cold Region

    By Masahiko Yamaki, Takahiro Yamanashi, Hijiri Hashimoto, Hirochika Hayashi

    "In this study, the authors used heat conduction analysis with the aim of quantitatively evaluating whether treating improved ground with cover soil is an effective measure for maintaining strength de

    Jan 1, 2015

  • DFI
    Evaluation of Elongation Criteria and Friction Loss in Ground Anchors

    By John P. Turner, Benjamin J. Turner

    "This report describes a research project for evaluating the applicability of the widely accepted 80 percent criterion for elongation of ground anchors to anchors with unbonded lengths exceeding 100 f

    Jan 1, 2017

  • DFI
    Effects Of Self-Weight On Thermomechanical Response Of Energy Piles

    By Arash Saeidi Rashk Olia, Dunja Perić

    The increasing demand for renewable energy has attracted attention to energy geostructures as means of extracting clean geothermal energy from the ground. To further advance the understanding of soils

    Oct 1, 2022

  • DFI
    A Review Low Strain Integrity Testing Practices In India And Complexities Involved In Evaluation Of Test Results

    By RavikiranVaidya, Vishal Dhamecha

    Low Strain Pile Integrity Testing has been used in India since 1990’s and several have tried to demonstrate the utility and benefits of this method. However, use of this technology was limited till 19

    Sep 1, 2022

  • DFI
    The Application of Rapid Load Testing In Singapore

    By Gilbert Chuah, Peter Middendorp, Joost Bakker, Soon-Hoe Chew

    "The Rapid Load Testing (RLT) of foundation piles has been applied worldwide since 1984. Several International and national codes are available, such as the Japanese Code of Practice (2002), ASTM D738

    Jan 1, 1900

  • DFI
    Seismic Stability Analysis of Seepage Control Measures for Levees in Central Valley, California

    By Zia Zafir

    "Levees in the central valley of California are primarily for flood control purposes and thus are subjected to infrequent hydraulic loading. The primary concern for these levees is their instability d