Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Augered Cast-In-Place And Continuous Flight Auger Pile Foundation Systems For US Highway Projects - Why ACIPICFA Pile Foundations?

    By Silas C. Nichols

    FHWA Interest is due to: ? An increase in successful projects in the U.S. private sector and in other countries ? Cost effective and more efficient in many circumstances ? Agency Prioritie

    Jan 1, 2005

  • DFI
    Performance of Large-Diameter Bored Pile Socketed In Sandstone and Siltstone in Thailand

    By Zaw Zaw Aye, Sereyroath Chea, Nutthapon Thasnanipan, Thayanan Boonyarak

    "As there are only limited numbers of bored pile constructed in sandstone and siltstone in Thailand, load transfer and settlement behavior of a pile in these rocks are still not fully understood. Majo

    Jan 1, 1900

  • DFI
    Up-Down Construction Utilizing Steel Sheet Piles And Drilled Shaft Foundations

    By Nathan A. Ingraffea

    The use of steel sheet pile walls and drilled shaft foundation elements to enable up-down construction methods has been used successfully on recent high-rise structures with multi-story below grade pa

    Jan 1, 2008

  • DFI
    A Numerical Study On The Lateral Resistance Of Steel-Concrete Composite Drilled Shafts For Long-Span Bridges

    By Juhyung Lee

    Recently, large diameter drilled shafts are often used for foundations of large-scale marine bridges with high capacity and required to resist lateral loads. Steel casings are essential in supporting

    Jan 1, 2008

  • DFI
    Suwanee American Cement Plant, Branford, Florida: A Case Study Of Large Diameter Continuous Flight Auger Design Build Foundations

    By Gordon King

    This paper presents a case study of large diameter continuous flight auger (CFA) piles and drilled shafts utilized for foundation support of a series of heavily loaded cement plant structures at the S

    Jan 1, 2003

  • DFI
    Augered Pressure Grouted Piles In Complex Glacial Soils - A Case Study - 1. Introduction

    By Peter J. Jancich

    This paper describes the installation of high capacity Augered Pressure Grouted piles which support structural loading from a four level parking garage in west-central DuPage County, Illinois. The sub

    Jan 1, 1991

  • DFI
    A Study Of Failure Mechanism And Uplifting Capacity Of Tension Pile Foundation ? Synopsis

    By K. J. Yang

    Based on investigations and model tests combined with pile foundation on Code compilation of drydocks, we present this report to give informations against uplift pressure of piles beneath floor of dry

    Jan 1, 2010

  • DFI
    Urban High Capacity Deep Foundation Solutions in Sites with Complex History and Geology

    By Karen C. Armfield, Gisele R. Passalacqua, Joanna Smith

    New York City is an urban environment with a history spanning over 200 years. The coastline of New York has changed over the years. In the East River, old bulkhead and remnant of relieving platforms t

    Jan 1, 2019

  • DFI
    St. Anthony Falls, I-35w Bridge Drilled Shaft Load Test Program

    By Jeffrey A. Gebhard

    As part of the design and construction of the new St. Anthony Falls I-35W Bridge, a full-scale load test was conducted on a 6 1/2-foot diameter drilled shaft in the St. Peter Sandstone. This load tes

    Jan 1, 2009

  • DFI
    Value-Engineering of H-Pile Foundations in Karstic Geology

    By Rachael M. Fischer, Daniel J. Woeste, Terence P. Holman

    "A new 50 MW biomass renewable energy power plant was planned for construction in southwestern Georgia. The original foundation design consisted of very conservatively designed H-pile groups with vert

    Jan 1, 2016

  • DFI
    Comparing Conflicting Conclusions from Different Integrity Testing Methods on the Same Drilled Shafts

    By Alex Ryberg, Matthew L. Becker

    Several integrity testing methods exist which may be used to evaluate drilled shafts. Each test method has advantages and limitations. On occasion, the results from different test methods may lead to

    Sep 8, 2021

  • DFI
    A Method For Predicting Load-Settlement Relationship And Bearing Capacity Of Single Piles By Means Of CPT

    By Wang Huichang

    A tentative mathod for predicting load-settlement relationship and bearing capacity of single piles based directly on the results measured by cone penetrometer with local friction sleeve is presented

    Jan 1, 1991

  • DFI
    Excavation-Induced Movement of Adjacent Foundations

    By Hugo Meggitt, Damian R. Siebert, Wystan Carswell

    Excavation-induced ground movements are a critical component in the design and construction of deep excavations in urban settings due to the potential adverse effects on adjacent structures and infras

    Jan 1, 2019

  • DFI
    Seasonal Strain Distributions in Full-Scale Energy Foundations (720c13b2-b754-45d9-8b84-e88f10ec05b5)

    By Kyle Murphy, John S. McCartney

    This paper focuses on the seasonal thermo-mechanical response of two energy foundations installed at the new Denver Housing Authority Senior Living Facility in Denver, Colorado. The two drilled shaft

    Jan 1, 2017

  • DFI
    Case Study: Design, Installation And Quality Assurance Testing Of High Capacity Socketed Piles In A Complex Geologic Environment

    By Thomas M. Caruso

    Construction of a new ship dock at a major Philadelphia area refinery required geotechnical design and field consultation. The new dock, which consists of a system of mooring dolphins and platforms,

    Jan 1, 2008

  • DFI
    Practical Construction Considerations for Runway Extension and Taxiway Expansion over Soft/Organic Soil Using a Column Supported Load Transfer Platform

    By Brian T. Nereson, Michael C. Penney

    "This technical paper was prepared to describe the general process by which the authors designed a column-supported load transfer platform (LTP) for support of asphalt-paved runway and taxiway embankm

    Jan 1, 2016

  • DFI
    Reliability Analysis of a Drilled Shaft Stabilized Slope System (e386e5ff-5c43-4c35-910f-4eb413f46379)

    By Lin Li

    A reliability based analysis method for a drilled shaft stabilized slope system is presented in this paper. In the past effort, a deterministic method using the limiting equilibrium method of slices f

    Jan 1, 2017

  • DFI
    Lateral Response of Pole on Engineered Driven Timber Pile Footing at Ararat Windfarm Terminal Station

    By Frank Albrecht, Brian McCarthy

    "The Ararat Terminal Station (ARTS) is located 190km to the north-west of Melbourne, approximately 1.7km to the north of Elmhurst Township in the Pyrenees region of western Victoria, Australia. The si

    Jan 1, 1900

  • DFI
    Design Of Cost-Effective Retaining Wall At The Junction Of Approach Bridge Over A Ramp

    By Dr. Anup Kumar Mandal, Partha Roy, Shuvranshu Kumar Rout, Dipak Mandal, Biswajit Das

    Installation of a new scalping station with bunker, apron feeder, scalping screen, ramp -retaining wall and approach bridge was planned in an existing integrated complex of phosphate fertilizer at a r

    Sep 1, 2022

  • DFI
    A Proposal For Construction Of The Pile Load-Settlement Curve Based On Results Of Cone Penetration Tests ? Synopsis

    By A. Tejchman

    On the site of building of a new flyover founded on piles the comprehensive "in situ" investigations were carried out. The subsoil conditions under each of 15 supports were very differentiated. Using

    Jan 1, 2010