Search Documents
Search Again
Search Again
Refine Search
Refine Search
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
-
Innovative Alternate Underpinning Solution for Historic Structure in Boston Suburb
By Eric P. Bregman, Justin Zarrella, Ryan M. Coulson, Connor Johnson
Within a prominent Boston, MA suburb are a pair of historic stone and mortar structures built in the late 1800’s. Both the Main House and Carriage House have been maintained and occupied throughout th
Sep 8, 2021
-
Rock Socket Piles In The Sherwood Sandstone Of Central Birmingham
By L. J. Whitworth
Five trial piles were constructed during the trial pile programme for the Birmingham International Convention Centre. In addition, trial piles have been tested on two other sites in central Birmingham
Jan 1, 1989
-
Analyses Of Dynamic Increasing Energy Load Test On Deep Foundations
By Silvana B. Foá
Results from full-scale loading tests showed the use of the dynamic increasing energy test (DIET) to verify the capacity of deep foundations. This method allows the measurement of dynamic resistance -
Jan 1, 2002
-
Safe Load Of A Single Pile In Earthquake Loading - Synopsis
By Shamsher Prakash
Estimation of vertical load carrying capacity of a single vertical pile under earthquake loading is an important task of a design engineer. Lateral vibration of vertical pile is highly influenced by t
Jan 1, 1996
-
Keynote Lecture 6: Mitsuhiro Shibazaki Jet Grouting
By Mitsuhiro Shibazaki
Generally, water-soluble polymers are effective in convergence of water jet ejected from a nozzle as they add viscosity to water. However, excessive additional polymers (added to keep water viscous) c
Feb 10, 2003
-
Vertical Load Carrying Capacity Of Concrete Expanded Base Piles
By Mustapha Zergoun
This paper presents the results of load tests to assess the vertical load carrying capacity of concrete expanded base piles, or pressure injected footings, for various projects located near Vancouver,
Jan 1, 2004
-
Design of Grillage and Helical Pile Foundation for Limited Access Transmission Line
By Benjamin Jennings, Jason Herron
In the summer of 2016 Xcel Energy experienced a storm event that resulted in the collapse of approximately 8.5 miles of a 345 KV transmission line near Rogers, Minnesota. In design of the new transmis
Jan 1, 2017
-
Application of Non-Destructive Testing to Drilled Shafts
Technically speaking, the concept of NDT sounds like the "magic bullet" when faced with a questionable drilled shaft. All the Contractor or Engineer needs to do is select an NDT method, apply it, unde
Jan 1, 2004
-
Slope Repairs in a Tight Footprint: Slope Stabilization Using Multiple Technologies
By Dan Mahrt
"In June of 2009, a slope failure occurred along River Road in Bismarck, North Dakota. The slope failure affected approximately 300 feet of River Road with vertical displacements up to 3 feet, resulti
Jan 1, 2016
-
A History Of The Use Of ACIP Piles For Major Projects In Atlanta
By Willie M. NeSmith
In the Metropolitan Atlanta Area today, augered, cast-in-place (ACIP) piles will be considered on most projects where deep foundation support is required. ACIP piles were first used in Atlanta in the
Jan 1, 2003
-
Uncertainties Arising During Drilling And Performance Of Flight Auger - Cast Piles
By F. M. Abdrabbo
Flight auger bored piles are formed by screwing a continuous flight auger into the ground, and pumping cement/sand grout or concrete down the hollow stem of the auger as its withdrawn. The auger is dr
Jan 1, 1993
-
Cofferdam Solution for Steeply Sloping Rock Using Flat-Sheet Piles
By Norm Kirk, Robert Bittner
"The addition of a new powerhouse at the existing Tulloch Hydroelectric site on the Stanislaus River in the western foothills of the Sierras Nevada Mountains of central California required a deep exca
Jan 1, 2017
-
Innovative Methods Of Dealing With Contaminated Soils In Drilled Shafts - Synopsis
By William F. Loftus
When high capacity diameter pipe piles are driven open-ended into the underlying bedrock, the material gathered inside the pipe often must be excavated to allow concrete to be placed within, in a clea
Jan 1, 1996
-
Completely Automatized Recognition of the Installation Process in Special Foundation Construction
By Christian Hoyme, Jochen Maurer, Hans Regler
Up to today, it has been very difficult to obtain qualitative and quantitative information about the status and production process of a construction site. It is becoming more and more important to be
Sep 8, 2021
-
LRFD For Deep Foundations: Replacing The Traditional Factor Of Safety In Design
By Lance A. Roberts
The Federal Highway Administration (FHWA) has mandated the use of the AASHTO Load and Resistance Factor Design (LRFD) specifications for all new federally-funded transportation infrastructure projects
Jan 1, 2008
-
Suction Bucket Installation
By Avi Shonberg
With the advancement of offshore wind farm projects towards deeper waters and larger wind turbine generators, founda- tion solutions other than the monopile have received increasing attention over the
Jul 1, 2022
-
Instrumented Pile Load Tests In The Area Of Pearl Harbor, Hawaii
By John Y. L Chen
This paper presents full-scale instrumented pile static compressive and tensile load tests to be conducted in the area of Pearl Harbor, Hawaii. Thousands of piles have been installed to support the ex
Jan 1, 2002
-
Micro-Biological Attack On Deep Foundation Concrete
By Piotr D. Moncarz
As major urban areas begin to run out of "good-terrain" for their expansion, they begin to claim high water-table areas within or adjacent to water fronts or swamps. Similarly, major infrastructure pr
Jan 1, 2002
-
Geophysical Investigations Enhance Geologic Characterization In Support Of Pile Foundation Program
By Mario Carnevale, Myles Danforth, Michael Oakland
The cost and overall effectiveness of foundation design depends on a robust characterization of the subsurface geologic setting. It is common practice to formulate deep foundation design from subsurfa
-
Jet Grouting Soft Clays for Tunnelling & Deep Excavations Design & Construction Issues
By Marcelo Chuaqui
We certainly have the data to back calculate it. I must admit that I haven't, at the moment my priority is not on what is the stiffness of the jet grout but is making sure that the jet grout is r
Feb 10, 2003