Search Documents
Search Again
Search Again
Refine Search
Refine Search
-
Improvements in Long Tendon Support with Pumpable Resin
By Tom Meikle
Long tendon support systems provide several challenges when used in-cycle as part of the secondary or primary support cycle. A two-component pumpable resin, Carbothix, has been in development for use
Jan 1, 2012
-
Massive Pillar Collapse: a Room?and?Pillar Marble Mine Case Study
By Sandin E. Phillipson
The Mine Safety and Health Administration?s Roof Control Division responded to a massive ground failure at an underground marble mine in northern Georgia. The ground failure occurred in a benched area
Jan 1, 2012
-
Quality Assurance in the Processing of Mining-Induced Subsidences and Research Work Into Mining Subsidence Engineering in the German Hard Coal Industry
By Peter Fischer
Between 45,000 and 50,000 claims for subsidence are submitted each year to the German hard coal industry. In order to improve the service to claimants a quality management was established in 2005. Thi
Jan 1, 2006
-
Comparative Study Of Western US Longwall Panel Entry Systems
By Khamis Y. Haramy
This paper summarizes ground control studies of longwall panel entry systems in two Western U.S. coal mines. Presented are comparisons of in situ pressure change measurements and assessments of chain
Jan 1, 1989
-
Field Verification of the Roof Fall Risk Index: A Method to Assess Strata Conditions
By Anthony T. Iannacchione
The Roof Fall Risk Index (RFRI) is a new method introduced by the National Institute for Occupational Safety and Health (NIOSH) to assist the underground stone mine operator in 1) assessing defects t
Jan 1, 2006
-
Insitu Performance of One Step Bolts to New Zealand Thick Coal Seam Mining Environments
By Richard Campbell
Effective strata control, utilising fully encapsulated resin grouted roof bolts is dependent on the installed quality of the reinforcement elements. Resin based grouts are the main form of rock bolt
Jan 1, 2006
-
Photogrammetric Monitoring of Rock Mass Behavior in Deep Vein Mining
By Donovan J. Benton
Photogrammetric methods are advancing rapidly and show considerable promise as a ground control research tool. The ability to quickly capture three-dimensional geometry, especially changes in geometr
Jan 1, 2014
-
Horizontal Stress and Coal Mines: Twenty-Five Years of Experience and Perspective
By G. J. Hasenfus
Although theoretical and conceptual knowledge regarding the impact of horizontal stress on underground coal mining excavations have existed since at least the mid-1900s, it wasn?t until the late 1970?
Jan 1, 2006
-
Empirical Mine Design for Western Underground Metal Mines
By Thomas M. Brady
The Spokane Research Laboratory/NIOSH and the University of British Columbia (UBC) geomechanics group are focusing on the development of safe and cost-effective underground design guidelines for weak
Jan 1, 2006
-
Rock Mechanics And Ground Control For Underground Mining And Construction
Recent improvements are described in several techniques for ground control in underground mining. Promising methods for analysis and mitigation of rockbursts are discussed. Methods of assessing damage
Jan 1, 1989
-
Time-Lapse Tomography of A Longwall Panel: A Comparison of Location Schemes (919eac95-0539-40b5-9304-f250d4890ab6)
By Kray Luxbacher
Three-dimensional time-lapse velocity tomograms were generated to image stress redistribution around a longwall panel to produce a better understanding of the mechanisms that lead to ground failure.
Jan 1, 2007
-
Load Transfer Distance Calibration of a Coal Panel Scale Model: a Case Study
By Mark K. Larson
Calibration of LaModel for deep coal mines begins with adjustment of overburden stiffness for load transfer distance. This calibration determines whether mining induced stresses are concentrated in th
Jan 1, 2012
-
Pillar Stability Issues Based on a Survey of Pillar Performance in Underground Limestone Mines (08bccb54-5d4b-443a-860e-90b5a6841ec3)
By Gabriel S. Esterhuizen
A survey of pillar conditions was carried out at 21 operating limestone mines that use the room-and-pillar method. The surveyed pillars were all located in rock that was classified as ?Good? to ?Very
Jan 1, 2006
-
Coal Bumps And Odd Dynamic Phenomena - A Numerical Investigation (70cea8ce-38a7-4c88-a596-77cf801d31b0)
By Jeffrey K. Whyatt
The Crandall Canyon accident investigation included an interesting and unexplained observation by rescuers that the ?barrier rib had shifted northward as a unit, as much as 10 feet.? This is not the
Jan 1, 2009
-
Main Gate Roof Support Design and Management During Longwall Retreat in the Australian Coal Industry
By Rob Thomas
Main gate roof control during longwall retreat is subject to a significant increase in horizontal stress and risk. The implementation and management of an appropriate roof support design is as a resul
Jan 1, 2006
-
Development of Low Profile Remote Roof Bolting Module
By Bill Kyslinger
In underground mining, machine design is predominantly dictated by mine conditions and individual customer desires. In partnership with Boart Longyear Poland and KGHM, J. H. Fletcher & Company was ta
Jan 1, 2006
-
Large Scale Ground Instability Caused By Failure of Underlying Pillars: A Case Study of Dynamic Multiple Seam Interaction
By Christopher Mark
Severe dynamic multiple seam interactions can occur when active mine workings are subsided by underlying mining activity. The most dramatic events are usually caused by longwall mining or pillar recov
Jan 1, 2012
-
Proposed Laboratory Quality Control Test Method for Resin Capsules Used in Underground Mines in South Africa
By Dave Minney
The South African mines health and safety regulations require that mine management establish a quality management system for rock support material. Quality control of resin capsules used as a support
Jan 1, 2007
-
Planning And Design For Barrier Pillar Recovery Three Case Histories
By David A. Newman
Barrier pillars created during mine development provide additional reserves during mine closure and can be the sole access to reserves previously abandoned because of mining height or out of seam dilu
Jan 1, 1995
-
Introduction of Long, High Capacity, Highly Tensioned, Post- Grouted Cable Bolts at BHP Billiton?s San Juan Mine,
By James Pile
Long, high capacity, highly tensioned, cable bolts (strand bolts), stiff enough to be installed with resin like a solid bolt, yet flexible enough to be used in any lengths, have been widely used in
Jan 1, 2007