Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Kinematic Load Tests On A Model Pile In Clay

    By Michael J. Brown

    Load testing is important for controlling the quality of piled foundations. The Statnamic test is an alternative to existing testing methods with a load duration that lies between that for static and

    Jan 1, 2002

  • DFI
    Instrumented Hybrid Shoring System for a Deep Temporary Excavation Incorporating Cutter Soil Mixing in Vancouver, BC, Canada

    By Nadir Ansari, Brian W. Wilson, Marina S. W. Li

    "A hybrid shoring system consisting of cast-in-place soldier piles with Cutter Soil Mixing (CSM) infill panels was constructed for temporary support of a 19.8 m (65 ft) deep excavation in Vancouver, B

    Jan 1, 2017

  • DFI
    Reliability of the Bearing Capacity of Axial Piles Using In Situ Tests

    By António A. Henriques, António Gomes Correia, Ana Teixeira

    "Abstract Pile foundations are often used for important structures, and thus, reliability evaluation is an important aspect of the design. Reliability methods have become increasingly important as dec

    Jan 1, 2014

  • DFI
    Lateral Load Capacity of Helical Piles in Sand

    By Balu E. George, Subhadeep Banerjee, Shailesh R. Gandhi

    "A three-dimensional analysis of laterally loaded helical piles installed in cohesionless soil is presented. Finite Element Analysis was conducted using commercially available Plaxis 3D AE version, as

    Jan 1, 2017

  • DFI
    American Developments In The Use Of Small Diameter Inserts As Piles And Insitu Reinforcement

    By D. A. Bruce

    The use of small diameter cast-in-place bored piles is becoming increasingly popular in the United States. Such inserts are used as conventional load bearing piles, and are generally referred to as pi

    Jan 1, 1989

  • DFI
    Determination of Initial Stiffness of Drilled Shafts for the Analysis of Settlements under Service Loads

    By Carlos A. Prato, Federico Pinto

    "ABSTRACTThe design of drilled shafts often incorporates large factors of safety, for which settlements under service loads are highly influenced by the initial elastic stiffness. In the case of group

    Jan 1, 2014

  • DFI
    Micropile And Soil Nail Load Transfer Rates In The Puget Sound Region Of Washington State

    By Carole L. B. Mitchell

    The increased use of micropiles and soil nailing presents a growing database of verification and sacrificial load test data. In Washington State, the use of micropiles is becoming common, and soil na

    Jan 1, 2006

  • DFI
    Augered Pile World Record Depth within a Soil Mix Basement

    By Andres M. Baquerizo, Jeremiah J. Filjones, Nicholas Feldt

    The Estates at Acqualina located in Sunny Isles Beach, FL, is comprised of two, ocean-front, 50-story, luxury towers with podiums and villas. With city regulations now requesting that above-grade floo

    Jan 1, 2019

  • DFI
    Evaluating Degree of Consolidation of Soft Soil by Using Asaoka, Hyperbolic and Back Analysis Method

    By Aminul Islam, Vinay M. Kumar

    "About 100 Hectares of land reclamation over the very soft to soft marine clay at Uran Creek in Maharashtra is planned. The depth of marine clay varies from 10m to 24m as observed from the geotechnica

    Jan 1, 2017

  • DFI
    State Of The Art In Double Rotary Drilling - Experience Gained From Practice

    By Markus Schönit

    Double rotary drilling combines continuous flight auger drilling with a casing for producing a cast-in-place pile. When producing a pile an outer casing and an auger (hollow auger) rotating inside

    Jan 1, 2011

  • DFI
    2D and 3D Finite Element Analysis for Cantilever Slurry Walls in Cohesionless Soil

    By Mostafa Mossaad, Ali Helwa, Manal Salem

    Support of excavation (SOE) design practice tends to model SOE elements using two-dimensional (2D) analyses to avoid the complexity associated with three-dimensional (3D) analyses. Such practice overl

    Jan 1, 2018

  • DFI
    Rigid Inclusions For Soil Improvement In A 76 Building Complex

    By Walter I. Paniagua

    A housing complex of 76 buildings is being constructed in the city of Morelia, in western central Mexico; the buildings are 5 levels high, with a shallow concrete slab foundation. Soil conditions incl

    Jan 1, 2008

  • DFI
    Innovative Cofferdams Used On The I-205 Columbia River Bridge

    By Robert Bittner

    The following is a report on the development of two unique and separate cofferdam systems used in the construction of the marine foundations for the I-205 Columbia River Bridge at Portland, Oregon for

    Jan 1, 2013

  • DFI
    The Historical Evolution Of Piling And Deep Foundations And Prospects For The Future.

    By W. G. K. Fleming

    The general history of piling is traced up to the present time with regard to the evolution of methods and materials. The processes have been strongly influenced by developments in basic equipment and

    Jan 1, 1999

  • DFI
    Data Normalization and User Interface Design for the Nevada Department of Transportation Deep Foundation Load Test Database

    By Austin Metz, Kevin Stanton, Ramin Motamed

    "A recent study calibrated Load and Resistance Factor Design (LRFD) resistance factors for local soil conditions in the Las Vegas Valley. As a part of this calibration, an extensive database of drille

    Jan 1, 2017

  • DFI
    The Design And Construction Of Large Diameter Base Grouted Piles In Thanet Sand At Blackwall Yard, London

    By J. A. Yeats

    This paper describes the loading to 25MN of a 1.2m diameter bored cast-in-situ test pile founded in the Thanet Sand which was base grouted. The pile was sleeved over the major portion of its length to

    Jan 1, 1989

  • DFI
    Bearing Capacity Of Piles Determined By Field Tests ? Synopsis

    By D. M. Milovic

    On the basis of relatively large number of field load tests of piles, the determination of the ultimate bearing capacity have been studied. Using the load settlement curves and the results of the cone

    Jan 1, 2010

  • DFI
    Route 49 (Penns Neck Bridge) Over Salem River

    By James E. Maccariella

    Replacement of an existing movable bridge with a new low level fixed bridge would not accommodate potential future navigation traffic. In order to replace the existing bridge in a cost effective m

    Jan 1, 2005

  • DFI
    Cyclic Degradation Of Pile Foundations For Offshore Wind Turbines

    By Fabian Kirsch

    Cyclic behaviour of axially loaded piles has been an issue since studies revealed that the capability to transfer skin friction into the ground is highly depending on the level and the number of load

    Jan 1, 2011

  • DFI
    Machine Foundation Repair

    By Scott D. Thomson

    The client for this project specializes in the use of state-of-the-art technology to fabricate and assemble composites and metal-bonded structures for commercial and military aircraft programs. One of

    Jan 1, 2003