Search Documents
Search Again
Search Again
Refine Search
Refine Search
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
-
Vertical Bearing Capacity of Pile Installed by "EX MEGATOP" Method - Base Enlarged Pre-boring and Grouting Method for Pre-cast PileBy Hitoshi Ogura, Koichi Kobayashi, Sadao Yabuuchi
"In Japan, most pile foundations using pre-cast concrete piles are installed by the bored pre-cast piling method, wherein pre-cast piles are installed in holes that have been excavated beforehand and
Jan 1, 2005
-
Session 29 "Grouting for Tunnels 1"By Lynn Crayne
We used Glyoxal as the hardener, at a final concentration of 10% by volume and therefore 20% by volume in the A-Component. They worked pretty well what we did was we shaved the joints on each of the
Feb 10, 2003
-
Analysis Of Vibratory Driven Pile ? IntroductionBy Sherrill Gardner
Vibratory drivers have been used since the 1930s to drive and extract piles. Vibratory pile drivers have the capability of significantly decreasing pile installation time, especially in granular type
Jan 1, 1987
-
Artificial Ground Freezing to Form Wall in TaiwanBy Ting-Wei Wang, Yung-Wen Chen
Artificial ground freezing is commonly used globally during excavation of shield tunnels and for groundwater control. It is a special construction method for temporary ground improvement that involves
Feb 1, 2022
-
Drilling And Grouted Pipe Pile Foundation For Department Of Energy Spallation Neutron Source Target Building, Oak Ridge, Tennessee ? IntroductionBy Ronald E. Walkington
The U.S. Department of Energy (DOE) is building the world's newest accelerator-based, pulsed-neutron system, called Spallation Neutron Source (SNS). The facility, located in Oak Ridge, Tennessee,
Jan 1, 2001
-
Design, Construction And Applications Of Auger Piling System For Earth Retention And Underpinning Of StructuresBy A. A. Gupte
Auger piling system which was developed in the United States in the 1940's is gaining acceptance in many parts of the world. Although primarily used to support foundations, the system is very use
Jan 1, 1989
-
Guidelines For Selection Of Parameters For Design Of Caisson Foundations For Certain Conditions. - SynopsisBy Dinesh R. Katti
Caissons which are locally known as well foundations, which may very in diameter from 30 m to more than 30 m and in majority of the cases having depth to diameter ratio between 1 to 1.5, are normally
Jan 1, 1996
-
Design Of Piles With The Dual Role Of Structural Stability And As A Sustainable Source Of Energy For The Heating And Cooling Of BuildingsBy Alice DiDonna
The heating and cooling of buildings worldwide represent a large amount of a country?s energy needs and are major sources of CO2. Therefore, decreasing the environmental impact of residential and offi
Jan 1, 2011
-
Ground Improvement For The Deep Foundation Of A 650 M Long Quay Wall In The Port Of HamburgBy Peter Arz
In the port of Hamburg a 650 m long quay wall was completed in mid-1985. The watertight wall consists of loadbearing steel buttress piles PSP 1012 which are up to 28 m long and infill interlocking she
Jan 1, 1987
-
Laboratory Validation Of In-Situ Tests - 1. IntroductionThis paper summarizes seven years of Italian experience with the use of large calibration chambers for the calibration, under closely controlled stress and strain conditions, of some in situ testing
Jan 1, 1987
-
Seasonal Strain Distributions In Full-Scale Energy FoundationsBy John S. McCartney
This paper focuses on the seasonal thermo-mechanical response of two energy foundations installed at the new Denver Housing Authority Senior Living Facility in Denver, Colorado. The two drilled shaft
-
St. Anthony Falls, I-35w Bridge Drilled Shaft Load Test ProgramBy Jeffrey A. Gebhard
As part of the design and construction of the new St. Anthony Falls I-35W Bridge, a full-scale load test was conducted on a 6 1/2-foot diameter drilled shaft in the St. Peter Sandstone. This load tes
Jan 1, 2009
-
Osterberg Cell Tests Confirm In-Situ Pier Capacity In Colorado - IntroductionBy William Siegel
Kleinfelder provided foundation analysis and design for an expansion to a cement plant in Florence, Colorado. The expansion was a conversion from a horizontal wet process to a vertical dry process, a
Jan 1, 2007
-
What Shapes Graduates' Skills with Sustainability?By Craig M. Shillaber
On any given day, a simple check of the news will turn up stories related to sustainability, resiliency, climate, or human or natural disaster. In recent years, the winter power grid failure in Texas
Nov 1, 2022
-
CPT Role in Rigid Inclusion Design and Quality AssuranceBy Jesus Gomez, Mary Nodine
Rigid inclusions are widely used in the U.S. as a ground improvement tech- nique, particularly for industrial, low- rise and highway applications with poor subsurface conditions, where control of sett
May 1, 2023
-
Pile Diameter Effects On Initial Modulus Of Subgrade Reaction For Laterally Loaded PilesBy Hubert Law, Amin Rahmani
This paper evaluates the effects of pile diameter on the initial modulus of subgrade reaction and proposes modifications to the subgrade reaction moduli that are commonly used in the current state of
-
Dynamic Testing Of Model Piles - A Laboratory Study - SynopsisBy P. Srinivasulu
The popular theoretical models used for assessing the dynamic behaviour of piles under vertical and lateral excitations are critically reviewed. An experimental study is presented on model piles with
Jan 1, 1996
-
Analysis On The Vertical Bearing Capacity Of Socketed PilesBy Yong Jingrong
Based on the results of several test socketed piles in Sichuan, the mechanism of the deformation for a loaded socketed piles is investigated, and the concept of the socketed effect is proposed. The be
Jan 1, 1991
-
Behaviour Of Model Pile Group Under Axial Monotonic LoadingBy A. Le Kouby
We present in this paper the results of a parametric study carried out in a calibration chamber on instrumented model piles. The aim is to point out group effect on piles within a group through their
Jan 1, 2006
-
Evaluation Of Degree Of Overconservatism In Api Shaft Friction Of Piles In Marine Sand Of The Arabian GulfBy Ahmed H. Bukhary, Naser A. Al-Shayea
The objective is to assess the overconservatism in the parameters used for designing offshore piles. Methodology includes analysis of shaft friction data obtained from more than five different locatio