Deep Foundation Underpinning Support For Fort Monroe, Virginia YMCA Historic Building Renovation
By David C. Kraft
Atlas Systems, Inc. (ASI) resistance type piers were used to underpin a 100 year old historic structure at Fort Monroe, Virginia. This 3-story structure with basement was underpinned with 155 steel tu
Jan 1, 2002
-
Design And Installation Of Pressure-Grouted, Drilled Displacement Piles
By Willie M. NeSmith
The use of drilled (screwed) displacement piles is an emerging sector of the United States deep foundation industry. During installation of these systems, a Ko to Kp environment is created in the mate
Jan 1, 2002
-
Effects Of Pile Driving In Saturated Soft Clay ? Synopsis
By R. L. Wei
The disturbing influences of pile driving on the surrounding soil mass, including the induced vibration, pore pressure and displacement of soil, were observed during the construction of pile foundatio
Jan 1, 2010
-
Pile Set-Up to Optimize High-Rise Bridge Design
By Charles Winter
The Ohio Department of Transpor- tation's (ODOT's) $228 million 1-480 Valley View Bridge project was needed to keep traffic flowing on one of the state's busiest freeway segments. Deterioration from a
May 1, 2022
-
Historical Evolution Of The Micropile "Palo Radice" - Inception Of The Micropile
By Pier Luigi Iovino
As Technical Director of the Naples, Italy based Fondedile, a geotechnical construction firm specializing in static restoration of structures, Fernando Lizzi, Ing., devoted over 30 years to the pursui
Jan 1, 2003
-
Session 11 Jet Grouting II
By George Burke
Of the three projects, particularly the extensive Nimitz II (downtown) project, a single system, which was part of the operation, was used to control the spoil. Spoil control was continuous with the w
Feb 10, 2003
-
Session 10 Deep Mixing Method I
By Peter Cali
There is one organization in Sweden, The Swedish Deep Stabilization Research Centre, which has been working with these questions and there is also a project, Eurosoilstab, within European Union to tak
Feb 10, 2003
-
I-880 Replacement Project (Cypress Freeway) Large Diameter Driven Pipe Pile Foundations Test Program And Construction - Implementation Of Test Results - Implementation
By Darrell L. Beddard
The test program information provided for some immediate changes on the upcoming contracts and in contract administration for the I-880 Replacement Project. Plan sheet modifications included changes t
Jan 1, 1996
-
Applying Reasonable Quality Control and Verification to Soil Mixing
By David Miller
"The biggest concern about using soil mixing is the inability to observe physically the final product, which has led to a lack of confidence about what is in the ground. After all, you can’t see it an
Jan 1, 2017
-
Numerical Study on the Behavior of Inclined Micropile (60b065bc-a615-421d-afa1-47c19339c8cb)
By Sepideh Damavandinejad Monfared
"In recognition of the practicality of using inclined micropiles as elements for foundation support to resist static and seismic loading conditions, specifically in retrofitting projects, this study p
Jan 1, 2017
-
Numerical Study On The Behavior Of Inclined Micropile
By Sepideh Damavandinejad Monfared
In recognition of the practicality of using inclined micropiles as elements for foundation support to resist static and seismic loading conditions, specifically in retrofitting projects, this study pr
-
Effective Plane Arrangement of Deep Mixing Piles to Resist Lateral Flow of Liquefied Ground
By Daiki Takano, Naoki Takahashi, Hidenori Takahashi, Ikuo Towhata, Yoshiyuki Morikawa
"The method in this study, in which cement-treated piles are installed into the ground to decrease the amount of liquefied lateral flow, has been studied. The authors are also investigating the most e
Jan 1, 2015
-
Combined Piled Raft Foundation (CPRF) response
By G. L. Sivakumar Babu, P. Chaithra
"Raft foundations which are used against differential settlements and for carrying heavy loads can still be subjected to excessive settlements even if it is safe against bearing capacity consideration
Jan 1, 2015
-
Deep Foundations: Study on Effect of Drilling Fluids on Concrete Integrity
By Alberto Carmona Rosell, Sri Ram Ramankutty
"The installation of Bored Piles and Diaphragm Wall under slurry using tremie raises quality concerns on the integrity of concrete. It is vital to understand the effects on concrete integrity during c
Jan 1, 2015
-
Uncertainties in CSL Test Interpretations and Recommendations toward a More Efficient Process (d88ba311-8a75-4265-90f4-c083be22cd1a)
By Mark A. Rohrbach, Timothy R. Kovacs, PhD Saidin
"Crosshole Sonic Logging (CSL) testing is commonly used to verify the integrity, quality and ultimately the acceptability of the concrete in structural elements such as drilled shaft foundations, seca
Jan 1, 2017
-
Back-Calculations Of Centrifuge Tests On Pile Groups Subjected To High-Cyclic Loading
By Torsten Wichtmann, Jan Macheck, Frederik Broz, Patrick Staubach, Hauke Zachert
The majority of heavy or strongly loaded structures, for instance high-rise buildings, large span bridges or gas storage tanks are founded on pile groups. However, current design codes and guidelines
May 1, 2022
-
Assessment of Analysis Techniques for Multi-Plate Anchors in Sand
By James P. Hambleton, Anastasia Nally
This work focuses on the numerical simulation of multi-plate anchor systems (e.g., helical anchors) in sand subjected to vertical loading. In assessing the stiffness and capacity of these multi-plate
Jan 1, 2019
-
Uncertainties In CSL Test Interpretations And Recommendations Toward A More Efficient Process
By Rohrbach
Crosshole Sonic Logging (CSL) testing is commonly used to verify the integrity, quality and ultimately the acceptability of the concrete in structural elements such as drilled shaft foundations, secan
-
Sustainability and Consideration of the Re-Use of Foundations for the Hurricane Deck Bridge
By Timothy C. Siegel, Paul J. Axtell
The Missouri Department of Transportation (MoDOT) recently replaced the Hurricane Deck Bridge that carries Highway 5 traffic across the Osage Arm of the Lake of the Ozarks in Camden County, Missouri.
Jan 1, 2017
-
Double Rotary Head Piling Systems (Cased CFA)
By Franz-Werner Gerressen
In the changing construction environment clients are searching for new technology to complete their projects in shorter times. Manufacturers are therefore developing solutions to speed up established