Search Documents
Search Again
Search Again
Refine Search
Refine Search
-
Surprises And Solutions When Driving Piles In Mountain Valleys Of VermontBy John E. Lens
Driving bridge foundation piles into glacio-fluvial sands and gravels and glacial tills brought surprisingly longer than predicted driving lengths on several recent projects in Vermont. In some insta
Jan 1, 2007
-
Behaviour Of Laterally-Loaded Piles Centrifugal And Numerical Modelling ? SynopsisBy W. H. Craig
Techniques have been developed for installing model piles into beds of soil under high sustained acceleration levels aboard a centrifuge. These piles have been subjected to static and/or cyclic latera
Jan 1, 2010
-
A History Of The Use Of ACIP Piles For Major Projects In AtlantaBy Willie M. NeSmith
In the Metropolitan Atlanta Area today, augered, cast-in-place (ACIP) piles will be considered on most projects where deep foundation support is required. ACIP piles were first used in Atlanta in the
Jan 1, 2003
-
High Strain Testing Of Large Diameter, High Capacity Unlined Bored Piles ? IntroductionBy Dhanvin B. Mehta
Pile testing is generally understood as static load test. It is our common experience that for high capacity, large diameter bored piles, static testing is expensive and time consuming. It is practica
Jan 1, 1996
-
Non-Destructive Testing Of Piles - A Case History - SummaryBy Manish Kumar
One of the recent advances in the field of testing of concrete piles is the Non-Destructive testing (NDT) of piles. This paper deals with a specific project where this technique was employed along wit
Jan 1, 1996
-
The Use of Bentonite in Underground ConstructionBy Hector Simchas
"1. BENTONITE: THE CRUCIAL CONSTITUENT OF SLURRYSuspensions of bentonite and water are used in a variety of applications in underground engineering. For the construction of underground elements like s
Jan 1, 2015
-
Non-Braced And Non-Anchored Diaphragm Walling In Soft Soil ? SynopsisBy D. Y. Peng
A Large Sub-structure with open top of S.Y.P. float line requires a 90m x 50m in plan and 13m-deep excavation in soft soil, Shanghai. The geological conditions in site are rather severe. The technolog
Jan 1, 2010
-
Determination Of The Load-Displacement Characteristics Of Single Pile In Soft Soil ? SynopsisBy Z. C. Chen
Based on the analysis of load test data of long floating piles in soft soil regions, the expressions of load-transfer function of pile shaft and tip for soft soils are presented in this paper, and the
Jan 1, 2010
-
Theoretical Simulation Approach For Load Settlement Characteristics Of Piles In Shale Deposits. - Synopsis :-By Subrata Ray
A large no of power stations are being set up in Chandrapur area having coal deposits. Several industries are also coning up in this area. The subsurface is geologically formed under Gondwana system a
Jan 1, 1996
-
Performance-Based Reliability Design for Deep Foundations Using Monte Carlo Statistical Methods (aa702b6b-e181-4fa5-97b3-2e3a1ab7040e)By Haijian Fan
Currently, deep foundation designs for the service limit state are deterministic in nature. The settlements and lateral deflections of deep foundations are calculated by means of numerical techniques
Jan 1, 2017
-
Reliability Approach For Deep Foundation Studies ? SynopsisBy R. Chowdhury
The relevance of reliability studies for deep foundations is considered in this paper with special reference to pile foundations. Attention is drawn to uncertainties related to applied loads, the load
Jan 1, 2010
-
New Load Testing DeviceBy Jorj O. Osterberg
This paper is for presentation at the 14th Annual Members Conference of the Deep Foundations Institute held at the Hyatt Regency Hotel, Baltimore Maryland on October 10, 1989. This is an introduct
Jan 1, 1989
-
Innovative Methods Of Dealing With Contaminated Soils In Drilled Shafts - SynopsisBy William F. Loftus
When high capacity diameter pipe piles are driven open-ended into the underlying bedrock, the material gathered inside the pipe often must be excavated to allow concrete to be placed within, in a clea
Jan 1, 1996
-
Correlations From In Situ Compression, Pull-Out & Lateral Load Tests On Piles ? SynopsisBy Madhira R. Madhav
In an alluvial deposit consisting of layers of sandy silt with clay and kankar nodules, driven cast in situ piles are provided. The piles end on a stiff bearing stratum To verify the available design
Jan 1, 1996
-
Interpreting Strain Measurements From Load Tests In Bored PilesBy Jack Hayes
Vibrating wire strain gages have proven to be a very reliable and effective tool for the measurement of strains associated with the loading of bored piles (drilled shafts). However, when these strains
Jan 1, 2002
-
Pile Foundations In Liquefiable Soils - A Case Study - SynopsisBy R. K. M. Bhandari
Geotechnical investigation for a LPG plant located in Assam state - an area of high seisimicty - revealed a layer of loose to medium silty sand susceptible to liquefaction at some depth below the fini
Jan 1, 1996
-
Research On The Interaction Between Pile And Foundation Soil By Boundary Element MethodBy Wang Lushuang
This thesis is devoted to the research of the interaction between pile and foundation soil by boundary element method (BEM for short). The interaction is simulated by the interaction between two diffe
Jan 1, 1991
-
Instrumented Pile Load Tests In The Area Of Pearl Harbor, HawaiiBy John Y. L Chen
This paper presents full-scale instrumented pile static compressive and tensile load tests to be conducted in the area of Pearl Harbor, Hawaii. Thousands of piles have been installed to support the ex
Jan 1, 2002
-
Performance Of Bituminous Coats In Reducing Negative Skin FrictionBy Makarand G. Khare
Though the phenomenon of dragload is known for many decades, there is a lack of clear guidelines to evaluate the amount of dragload. The development of dragload depends on relative movement between pi
Jan 1, 2006
-
Guidelines For Selection Of Parameters For Design Of Caisson Foundations For Certain Conditions. - SynopsisBy Dinesh R. Katti
Caissons which are locally known as well foundations, which may very in diameter from 30 m to more than 30 m and in majority of the cases having depth to diameter ratio between 1 to 1.5, are normally
Jan 1, 1996