Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • NIOSH
    Utilization And Efficiency In Underground Coal Mine Electrical Systems

    By Lloyd A. Morley

    To reduce safety and production problems, it is essential that the electrical operating characteristics of coal mining equipment and their electrical subsystems be clearly understood. The Bureau of Mi

    Jan 1, 1975

  • NIOSH
    Statistical Summary (ecbc64e0-a390-45f6-a086-708a6a65c155)

    By Rose L. Ballard

    This chapter summarizes data on crude nonfuel mineral production for the United States, its island possessions, and the Commonwealth of Puerto Rico. Included also are tables that show the principal no

    Jan 1, 1981

  • NIOSH
    Installation Techniques - 6.1 The Basic Philosophy

    The investment involved in any communication system represents a considerable sum. Even though it is desirable that the system work properly each and every time it is called into use, some failures ar

    Jan 1, 1984

  • NIOSH
    Avoiding Contamination Of Overburden Drill Samples ? Objective

    Avoid errors in determining the amount of trace elements in overburden when core drilling samples, particularly as required by PL 95-87, the Surface Mining Control and Reclamation Act of 1977. Rea

    Jan 1, 1981

  • NIOSH
    RI 8038 Precision Tests of Neutron Sulfur Meter in Coal Preparation Plant

    By A. W. Hall

    A neutron meter was developed for monitoring the sulfur content of coal streams. Neutrons from 80 micrograms of californium-252 penetrate the coal, producing thermal neutrons that are captured by atom

    Jan 1, 1975

  • NIOSH
    Side-Boom Scrubber For Continuous Miner Dust Control - Objective

    Reduce mine worker dust exposure by capturing airborne coal and quartz dust generated by a continuous mining machine. Approach Install a water-powered scrubber system operating at 1,000 psi on t

    Jan 1, 1989

  • NIOSH
    Improved Underground Rerailing Methods Enhance Safety and Efficiency - Objective

    Increase the safety of underground mine workers by minimizing hazards associated with rerailing mine cars after derailment. Background and Approach A serious operational problem in underground m

    Jan 1, 1986

  • NIOSH
    Permissible Wireless Real Time Survey Tool - Objective

    Provide the mining industry with a wireless surveying system for increasing efficiency in the drilling of methane drainage or exploration boreholes. Approach The Bureau of Mines has pioneered th

    Jan 1, 1984

  • NIOSH
    Trailing Cable Damage--Causes And Prevention

    By James J. Hanslovan

    Stresses that damage coal mine trailing cables were investigated to obtain a quantified description of cable-stress locations, magnitudes, and frequency of occurrence. Stresses occurring in operating

    Jan 1, 1979

  • NIOSH
    Introduction (72b35a0d-7906-40a6-80ae-59dfea0c6d84)

    By Thomas V. Falkie, R. Venkataramani

    The purpose of this work was to Investigate the rate at which coal is delivered from the underground working face by gathering arm type loaders as employed on continuous mining machines, to identify t

    Sep 1, 1972

  • NIOSH
    RI 7425 Investigation Of A Low-Grade Gold Deposit In The Orogrande District, Idaho

    By William L. Rice

    Geochemical humus sampling techniques were used by the Bureau of Mines in investigating a potential large, low-grade gold deposit in the Orogrande district, Idaho. Conifer needle humus samples were pr

    Jan 1, 1970

  • NIOSH
    RI 7186 Field Freezing Of A Cerium-Iron Alloy

    By J. E. Murphy

    Field freezing was used by the Bureau of Mines to effect the redistribution of the components in a cerium-12.5-atomic-percent-iron alloy. The application of the electric field caused the iron to migra

    Jan 1, 1968

  • NIOSH
    RI 7553 A Three-Dimensional Dynamic Programing Method For Optimal Ultimate Open Pit Design

    By Thys B. Johnson

    A three-dimensional dynamic programing method is presented for determining the optimal ultimate open pit limit. The method given is based on the block concept and is an extention of the two-dimensiona

    Jan 1, 1971

  • NIOSH
    RI 8064 Dust Suppression With Water Sprays During Continuous Coal Mining Operations

    By J. E. Emmerling

    The Federal Bureau of Mines investigated dust suppression obtained with three different water-spray nozzle systems during underground continuous coal mining at the face. The nozzles were the "regular"

    Jan 1, 1975

  • NIOSH
    RI 8295 - Methane Drainage: Experience With Hydraulic Stimulation Through Slotted Casing

    By Stephen W. Lambert, Michael A. Trevits

    The Bureau of Mines examined the wellbore of a vertical gas drainage well in the Mary Lee coalbed to determine the results of specific completion procedures in coal. A jet-slotting tool was used to cu

    Jan 1, 1978

  • NIOSH
    RI 7039 Reaction Rate Of Titanium-Iron Alloys And Titanium Trichloride In Molten Sodium Chloride

    By E. K. Kleespies

    The Bureau of Mines determined the kinetics of the reaction of titanium-iron alloys with titanium trichloride dissolved in sodium chloride to provide a basis for understanding the reactions occurring

    Jan 1, 1967

  • NIOSH
    RI 8509 Flotation Responses of Two Duluth Complex Copper-Nickel Ores

    By R. B. Schluter

    The Bureau of Mines investigated the flotation responses of two copper-nickel ore samples from the Duluth Complex with the objective of recovering bulk sulfide concentrates. One of the ores studied wa

    Jan 1, 1980

  • NIOSH
    RI 8247 - Geology And Gas Content Of Coalbeds In Vicinity Of Bureau Of Mines, Bruceton, Pa.

    By C. H. Elder, M. C. Irani

    Two degasification test boreholes were drilled to depths of 1,238 and 1,212 feet on Bureau of Mines property at Bruceton, Pa., as part of the Bureau's long-range coal degasification program. The

    Jan 1, 1977

  • NIOSH
    RI 9639 - Detection of Downed Trolley Lines Using ARC Signature Analysis

    By Gregory P. Cole, Jeffrey Shawn Peterson

    The Pittsburgh Research center3 conducted research to study and improve electrical fault detection on coal mine direct-current (dc) trolley systems. A suspended trolley line delivers power at voltages

    Jan 1, 1997

  • NIOSH
    RI 8223 Control of Pneumatic Chipping and Grinding Noise

    By Aarne Visnapuu

    Pneumatic chipping, scaling, and grinding can expose the tool operator to noise levels in the range 90 to 120 dbA. In most chipping and scaling operations, casting resonance is the primary source of n

    Jan 1, 1977