Dynamic Behavior Of Pile Foundations
By Yingcai Han
The dynamic behavior of pile foundations is investigated in both theory and practice. The computation method for vibration of pile foundations and DYNAN computer program are introduced comprehensively
Jan 1, 2002
-
A General Formula To Determine The Allowable Pile Bearing Capacity In Case Of Negative Skin Friction ? Summary
By Cornelis Van Der Veen
Foundation piles, partly passing through unconsolidated compressible layers, suffer a downward drag that is called negative skin friction. The negative skin friction depends on the movement of the sur
Jan 1, 2010
-
Design Of Well Cap, Pier And Well Steiming At The Junction Using Strut-And-Tie Model - Synopsis
Pier, well cap and steining junction is a complicated 3-d re-ion. The prevalent design procedure for the pier, well cap and steining in isolated manner is not rational. In absence of an integrated app
Jan 1, 1996
-
Behavior Of Pile Foundation Under Impact Lateral Loads
By Hajialilue Bonab M.
The soil-pile interaction under lateral impact loads is not yet completely well known. Many tests on single piles under static lateral loads in centrifuge have been performed and P-y curves have been
Jan 1, 2002
-
Comparison Between Statnamic And Static Load Testing Of Drilled Shafts In Varved Clay
By Carl Ealy
Static and STATNAMIC (STN) rapid load test (RLT) was performed on 3-drilled shafts. The purpose of the RLT part of the study was to obtain data in support of FHWA research on innovative load testing m
Jan 1, 2002
-
Estimating Axial Displacements Of Driven Piles In California Soils
By Cem Akgüner
The displacements of axially loaded single piles are analyzed with an approach based on elasticity. Young?s modulus and Poisson?s ratio of the soil encompassing a pile are the unknowns required as in
Jan 1, 2008
-
Piles Lateral Force Capacity
By Naim Noori Samie
Lateral force rsistance of piles is analytically investigated by dividing the pile length to 3 segments. The first segment (Zone I) models the load eccentricity with respect to the soil and the pile-d
Jan 1, 1996
-
Deepest Ever Large Diameter Pipe Pile Installation Demonstration Project New East Span San Francisco-Oakland Bay Bridge
By Saba Mohan
For the three full-scale pile installations, two different high-energy hydraulic hammers were selected for the installation. However, these hammers may not have sufficient energy to drive these large
Jan 1, 2002
-
Practice Of Large Diameter Stepped Section Bored Pile Foundation Of A Deep Water Bridge
By Cen Guoji
The foundation of bored pouring concrete pile have been adopted in the bridge engineering of China since early in the sixties. They demonstrated tremendous technical advantage and achieved notable eco
Jan 1, 1991
-
The Stability Of A Diaphragm Wall ? Synopsis
By X. L. Chen
The diaphragm walling has been recently adopted in one of the largest excavation of deep foundation engineerings in Shanghai, China with dimension of 90m in length, 50m in width and 13m in depth to so
Jan 1, 2010
-
The Behavior And Design Of Piled-Raft Foundations Under Lateral Loading
By Serge Borel
An efficient design method is proposed for "piled-footing" and "piled-raft" foundation under lateral loads. It combines the methods used for the displacement design of shallow and deep foundations and
Jan 1, 2002
-
Load Tests On Belled Piles With Polystyrene Foam Between The Shaft And The Base
By José Carlos A. Cintra
This paper addresses a new experimental procedure to measure the shaft friction and the base resistance of bored piles during static load tests. It is proposed that a set of polystyrene foam discs, pl
Jan 1, 2002
-
Lessons Learned From Mitigating Early Project Delays To Deep Foundation Work
By Jeffery L. Ottesen
Early construction delays can jeopardize timely completion of subsequent work. As an early construction activity, and due to many unforeseen issues, deep foundation work inherently bears great potenti
Jan 1, 2002
-
Structure Monitoring During Underpinning
By Barry C. Roth
A Real Time Automated Remote Reading Electrolytic Tilt Monitoring System was effectively deployed for monitoring an existing five story brick building during underpinning, shoring and excavation opera
Jan 1, 2007
-
Guidelines For Selection Of Parameters For Design Of Caisson Foundations For Certain Conditions. - Synopsis
By Dinesh R. Katti
Caissons which are locally known as well foundations, which may very in diameter from 30 m to more than 30 m and in majority of the cases having depth to diameter ratio between 1 to 1.5, are normally
Jan 1, 1996
-
Using Dynamic Pile Testing To Overcome Surprising Soil Variations
By H. (Sam) Salem
A site investigation for a wide and tall hotel building, in the San Juan Bay area, Puerto Rico, indicated a soil profile of silty clay on sand, soft and loose enough to require piled foundations. The
Jan 1, 2008
-
Capacity Prediction Vs. Performance Of Driven Pre-Cast Pre-Stressed Concrete Piles In Chesapeake, Virginia
By Emad Farouz
This paper compares the predicted axial capacity of driven Pre-cast Pre-stressed Concrete (PPC) piles for the Lake Gaston Water Treatment Plant (LGWTP) using several design methodologies versus the ax
Jan 1, 2007
-
Remedial Work On Large Pile Deviation In The Very Thick Marine Swamp Clay Deposit
By Wanchai Teparaksa
Pile deviation generally can happen after installation of driven pile particularly in soft soil layers. In this case study, all 242 diameter 0.8 m spun piles were deviated from 20 to 820 mm. The large
Jan 1, 2002
-
Evaluation Of Pile Load Test Results
By Rasin Duzceer
In this paper, the results of pile load test on 24 piles from twelve sites are presented. The pile load tests were performed on 14 driven and 10 bored piles of varying diameters and lengths installed
Jan 1, 2002
-
Design Of The Marine Foundations For The Skyway Project Of The San Francisco Oakland Bay Bridge
By Gerry Houlahan
The east span of the 3.5 km long SF-Oakland Bay Bridge is supported by different types of foundations along its span. Starting from the west, its first 460 m section comprising twin concrete box-girde
Jan 1, 2013