  • DFI
    Geophysical Methods for Site Characterization for Marine Foundations (2dc87bb8-7bfd-4523-92cd-c3dfe612556c)

    By Richard E. Sylwester

    Evaluating surface and subsurface conditions for marine foundations (bridges, causeways, terminals, etc.) is often done with a limited amount of data. Subsurface information for these projects is prim

    May 11, 2007

  • DFI
    Deep Soil Mixing Trials at Porto Alegre Airport, Brazil

    By A. Ortigão, M. Felix, E. Falk, T. Koehler

    "Ground improvement techniques such as vibro-replacement or deep soil mixing are fairly young products in the Brazilian geotechnical market. Soft soils in this country are deep, very soft, have low se

    Jan 1, 2015

  • DFI
    Liner Piles Used As Support To Kentledge For Initial Compression Load Test

    By Venugopal B, M Kumaran, Thomas John, Vetriselvan A

    The initial pile load tests are conducted to ensure the geotechnical capacity of the pile in a particular site condition. Normally kentledge method is adopted for the compression pile load tests. In t

    Nov 1, 2022

  • DFI
    A Proposal For Construction Of The Pile Load-Settlement Curve Based On Results Of Cone Penetration Tests ? Synopsis

    By A. Tejchman

    On the site of building of a new flyover founded on piles the comprehensive "in situ" investigations were carried out. The subsoil conditions under each of 15 supports were very differentiated. Using

    Jan 1, 2010

  • DFI
    Case History: Innovative Load Test Program Optimizes Pile Capacity in Challenging Ground Conditions

    By Emad Farouz, Francis A. Abreu

    "This paper presents a case history of a successful construction-phase pile load test program that optimized the pile design in challenging ground conditions at the Great Neck Wastewater Treatment Pla

    Jan 1, 2017

  • DFI
    1785 Massachusetts Ave. NW, Washington, D.C.

    By Daniel Stevenson, Richard Guenther

    "The preservation of historic buildings is not only essential to the understanding of our national heritage, but it is also environmentally responsible to adapt existing buildings to compatible new us

    Jan 1, 2017

  • DFI
    Design And Construction Of The Deepest Cfa Pile In Australia

    By W. L. Chong

    For a project located in Docklands Victoria, a high-rise development was proposed where the geology comprised soils of various compositions and consistencies to approximately 50m deep before being und

    Nov 1, 2022

  • DFI
    Sustainable Products For Geotechnical Works

    By Marcus Daubner, Karsten Beckhaus, Florian Bauer

    The construction industry can and needs to contribute to a more sustainable world. Accordingly, geotechnical works potentially have a significant share. In this context, Bauer understands “sustainable

    May 1, 2022

  • DFI
    Underpinning System Based On Preloaded Micropiling For Construction Of Additional Underground Floors

    By Wolfram Groh

    New underground floors comprising the complete footprint area of the building structure, were constructed under an existing building in sand, located in the Verdun district of Beirut / Lebanon. The wo

    Jan 1, 2002

  • DFI
    Overview Of Enabling Works For Waterfront Structures – Design & Construction

    By Nagarajan. D, Raja Rajan. K, Vijayakumar. T

    Major bridges crossing mighty rivers must be constructed in flowing water. Constructing the sub-structure in water has been a challenging job for contractor. Special construction techniques with marin

    Nov 1, 2022

  • DFI
    State of the Art Ground Improvement Technique for a Residential Complex: Case Study

    By Madan Kumar Annam, Hari Krishna Y, I. V. Anirudhan

    "For completion of projects in time with positive results, improvements of productivity and effective project management procedures have become extremely important. This paper discusses a milestone pr

    Jan 1, 2015

  • DFI
    Investigations on the Distress to the Pavements/PQC Slab around Monorail Piers, Wadala, Mumbai

    By Unnikrishnan Nair, Sandeep S. Nikam, Sanjay D. Patil, Prabir C. Basu

    "Mumbai Metropolitan Region Development Authority (MMRDA) entrusted to implement Monorail Systems in various parts of Mumbai Metropolitan Region (MMR) with the objective to supplement the present tran

    Jan 1, 2015

  • DFI
    Soft Deep Mixing for the Mitigation of Seismic Risk

    By A. Flora, E. Bilotta, F. Foria, V. Nappa

    "All the typical applications of deep mixing rely on the good mechanical properties of the improved columns to strengthen or stiffen the ground for a number of geotechnical applications.This paper foc

    Jan 1, 2015

  • DFI
    Underwater Pile Hammers

    By Douglas L. Scaggs

    Driving piles in under water applications has become more common place over the past twenty years. Where only a water depth reachable with a follower or dewatered cofferdam was the rule in the past,

    Jan 1, 2013

  • DFI
    Adaptive Design and Contractual Approaches to Address Geotechnical Uncertainties in a Design-Build Ground Improvement Project

    By Kalyani Devabhaktuni, Mike Minton, Mark T. Howe, Yan Zhang

    During the procurement phase of a Design-Build (DB) project, design-build contractors must often commit to a fixed price based on limited or incomplete geotechnical information. This lack of informati

    Jan 1, 2019

  • DFI
    Experimental Study on the Bending Failure Properties of Cement-Treated Soil

    By Takeru Fukaya, Tsutomu Namikawa

    "The bending tensile stress occurs in the ground improvements when external forces are applied to the column and wall shaped ground improvements. Therefore, in the design of the column and wall shaped

    Jan 1, 2015

  • DFI
    Trouble In Paradise: Micropiles As A Solution To Challenging Geotech And Steep, Rugged Terrain On The Island Of Oahu

    By Steve Davidow, Scott Tunison

    As the demand for electric power grows and generation facilities are constructed in more remote areas, the industry faces an increasing number of foundation construction challenges. The importance of

  • DFI
    Design, Prediction And Performance Of Tied Back Shotcrete Walls Supporting Masonry Hospital Structures

    By Frank Borda

    Two recent projects were completed in Ontario, Canada for major hospital additions that involved excavation support of heritage masonry structures. Conventional continuous caisson wall schemes were re

    Jan 1, 2004

  • DFI
    Environmentally Friendly Geothermal Piles At Keble College, Oxford, UK

    By Tony P. Suckling

    This paper presents a case study of a piling contract undertaken at Keble College in Oxford in the year 2001. Unusually, and for the first time in the United Kingdom, piles were successfully construct

    Jan 1, 2002

  • DFI
    A Geotechnical Instrumentation Case Study

    By Mehih Demirkan, Kevin Tehansky

    Located about an hour drive south from Washington, D.C., the Maryland Transportation Authority (MDTA) contracted with Skanska-Corman-McLean (SCM) to deliver a new Governor Harry W. Nice Memorial/Senat

    Apr 1, 2023