Search Documents
Search Again
Search Again
Refine Search
Refine Search
-
Real-Time Anchor Testing and Data ManagementBy Bora Okumusoglu, Devon K. V. Mothersille
"AnchorTest is an innovative software package, specifically developed for tablets, that permits ground anchor test data assessment and management in real time. The solution has two components: a front
Jan 1, 2017
-
Construction Of The Main Tower Pier Caissons For The Greenville Bridge In MississippiBy F. Keith Jacobson
To be involved in the construction of a deep dredged caisson for a major bridge pier is one of the most rewarding and professionally challenging experiences one can have in the bridge construction bus
May 11, 2007
-
Sunrise Powerlink: An Innovation in Foundation DesignBy Steve Davidow, Nick Salisbury
"The Sunrise Powerlink project received numerous industry awards for excellence. The DFI C. William Bermingham Innovation Award recognized the innovative use of prefabricated steel micropile caps to i
Jan 1, 2014
-
Route 9A Pedestrian Tunnel at the World Trade CenterBy Raymond E. Sandiford
"The redevelopment of the World Trade Center (WTC) provided an opportunity for the Port Authority of NY and NJ to complete a long sought underground connection between all of Lower Manhattan’s transit
Jan 1, 2012
-
Testing Foundations for Major Minnesota BridgesBy Dan A. Brown, Rich A. Lamb, Paul J. Axtell
"Over the last 10 years, the Minnesota Department of Transportation (Mn/DOT) has had a very active program of replacing many major bridges, large structures spanning the Mississippi River. The deep fo
Jan 1, 2013
-
Pile Foundations for the San Francisco 49ers NFL StadiumBy Scott A. Walker, Gabriel J. Alcantar, Brian Zuckerman, Ramin Golesorkhi
"The new San Francisco 49ers Levi’s Stadium is part of the next generation of sporting facilities. Constructed in Santa Clara, Calif., the new structure has 68,500 open-air bowl seats and includes a 7
Jan 1, 2014
-
Vibration Isolation at the Dana-Farber Yawkey Center: OPA FinalistBy David R. Shields, Michael T. Bracher
"The $330 million (U.S.) Dana-Farber Cancer Institute’s Yawkey Center for Cancer Care (Yawkey Center) sits in the heart of Boston’s Longwood Medical Area. The Yawkey Center is a cutting-edge cancer ca
Jan 1, 2012
-
Deep Drilling at Mica Dam, British ColumbiaBy Douglas G. Baker, Jason K. Braund-Read, Megan R. Sheffer
"Mica Dam, owned by British Columbia Hydro, is an 820 ft high earthfill embankment dam that was completed in 1973. The dam consists of a thin central impervious till core supported by upstream and dow
Jan 1, 2017
-
Correlations From In Situ Compression, Pull-Out & Lateral Load Tests On Piles ? SynopsisBy Madhira R. Madhav
In an alluvial deposit consisting of layers of sandy silt with clay and kankar nodules, driven cast in situ piles are provided. The piles end on a stiff bearing stratum To verify the available design
Jan 1, 1996
-
The Theory Of The Expansion Of Cavities Applied To Pile Installation ? SynopsisBy D. A. Ponniah
The installation of a pile is considered analogous to the expansion of a cylindrical cavity of a diameter equal to that of the pile. Using Vesic's theory of the expansion of cavities the effect o
Jan 1, 1987
-
Studies On Pile Driving Cushion Materials ? SynopsisBy H. R. Shen
Cushion materials are one of the most important links in an efficient piling system. In the past, little has been done in China on this problem, so engineers are still used to those traditional woods,
Jan 1, 2010
-
Design Criteria Of Dynamic Consolidation ? SynopsisBy Z. Q. Wang
The author is trying to clarify the existing problems in designing and laying out dynamic consolidation for soft ground improvement. Field testings and observations including vibrational parameters, p
Jan 1, 2010
-
Design Method For Bridge Abutment Foundation Piles Subjected To Lateral Earth Pressure ? SynopsisBy T. Matsui
Many existing bridge abutments on the soft ground laterally move and their many damage examples have been reported. An essential cause for the troubles of the lateral movements may be the lack of exam
Jan 1, 2010
-
Professional Responsibilities In Sub-Surface Investigations For Foundations. - IntroductionBy D. J. Ketkar
It is a frequent experience to find that the Sub-surface Investigation (S.I.) data is either inadequate or misleading. However, such cases are rarely reported. Nonetheless, the projects suffer on-acco
Jan 1, 1996
-
Foundation Code8 And Linit 8tatb Partial Factoring - SynopsisBy W. G. K. Fleming
The codification of foundation design and construction is a subject of extensive discussion in Europe and all current code proposals are based on limit state partial factoring. For simplicity, it is c
Jan 1, 1996
-
Piled Raft System - Approximate Design Methods. - SynopsisBy S. L. Karunakaran
There are cases where it is found that a raft foundation would have adequate factor of safety against ultimate bearing capacity failure but the settlements would be excessive. Piles may be introduced
Jan 1, 1996
-
Pile Foundations In Liquefiable Soils - A Case Study - SynopsisBy R. K. M. Bhandari
Geotechnical investigation for a LPG plant located in Assam state - an area of high seisimicty - revealed a layer of loose to medium silty sand susceptible to liquefaction at some depth below the fini
Jan 1, 1996
-
A Study Of Failure Mechanism And Uplifting Capacity Of Tension Pile Foundation ? SynopsisBy K. J. Yang
Based on investigations and model tests combined with pile foundation on Code compilation of drydocks, we present this report to give informations against uplift pressure of piles beneath floor of dry
Jan 1, 2010
-
High Strain Testing Of Large Diameter, High Capacity Unlined Bored Piles ? IntroductionBy Dhanvin B. Mehta
Pile testing is generally understood as static load test. It is our common experience that for high capacity, large diameter bored piles, static testing is expensive and time consuming. It is practica
Jan 1, 1996
-
Assessment Of Safe Load On Piles Using Indian Standard Codeprivate ? SynopsisBy Shenbaga R. Kaniraj
The pile loading tests are generally conducted to assess the safe load on piles in compression. In the Indian practice, the safe load is determined using the pile loading test data and the two criteri
Jan 1, 1996