Search Documents
Search Again
Search Again
Refine Search
Refine Search
-
A Field Study to Analyze Pile Setup Behavior and Comparison of Pile Capacity Methods from CPT
By Md. Nafiul Haque, Murad Y. Abu-Farsakh, Chris Nickel
"This paper presents the results from a pile load testing program for a bridge construction project in Louisiana. The testing includes two 54-inch open-ended spun cast concrete cylinder piles (OECP),
Jan 1, 2017
-
Using Large Pile Driving Hammers For The Foundation Of Bridges And Windparks
By Bernhard Bruggaier
Outside the oil and gas industry there is an increasing demand to install big piles for the foundation of ports, bridges, and wind-energy plants. This article introduces the design and techniques in u
Jan 1, 2002
-
JFKIA - Post Grouted Drilled Shafts And Driven Piles - Update - Synopsis
By Walter G. Brusey
This paper describes a comprehensive pile test program conducted at John F. Kennedy International Airport (JFKIA) to evaluate pile types and design capacities ranging from 890 to 4450 KN (100 to 500 t
Jan 1, 2000
-
Settlement Monitoring Of A Building Underpinned With Micropiles And Soil Nails
By Bill Zietlow
A micropile and soil nail underpinning system was installed to support a building immediately adjacent to a 25-ft deep excavation in downtown Salt Lake City, Utah. Both the building and the underpinn
Jan 1, 2008
-
The Geology Of South Florida With Emphasis On Deep Foundations
By Edwin W. Hickey
This paper briefly discusses the geologic conditions in South Florida relative to the design, construction, and performance of deep foundations. The subsurface conditions in this area are unique in th
Jan 1, 2003
-
Comparison of Non-Destructive Integrity Tests on Experimental Drilled Shafts
By Armin W. Stuedlein, Jim Zammataro, Bernie Hertlein, Daniel Belardo, Qiang Li, Antonio Marinucci
"An experimental program focusing on four drilled shafts was conducted to determine the effect of high strength steel reinforcement bars on lateral resistance, steel casing on axial and lateral resist
Jan 1, 2016
-
Load Tests Of Bored Piles In Weathered Bedrock
By James C. Scott
Compression and tension load testing were performed on bored concrete piles installed to depths of 18 to 34 meters below excavation levels for a large mixed-use development in Kuala Lumpur, Malaysia.
Jan 1, 2007
-
Microstructure of Bio-Cemented Coarse Sand
By Abdelmalek Bouazza, Aamir Mahawish, Will P. Gates
Bio-grouting by means of microbial induced calcite (calcium carbonate) precipitation (MICP) to improve mechanical properties of granular soils has gained much attention in recent years. The biogroutin
Jan 1, 1900
-
University Of Minnesota Football Stadium Down Hole Pile: Innovative Solution For Difficult Conditions
By Eric J. Pederson
The down hole hammer is widely used in specialty geotechnical construction. The common uses include tie-back anchor installation, micropile installation, and general soil/bedrock drilling operations.
Jan 1, 2008
-
Performance Of Drilled Displacement Piles In The Midwestern United States
By W. Morgan NeSmith
Drilled displacement (DD) piles often develop significantly larger unit shaft resistance values than other drilled or augered pile systems in coarse grained materials. Minimal vibration and limited sp
Jan 1, 2009
-
Effects Of Confining Stress During Curing And Shearing On Shear Strength Of Lime-Cement Improved Clays
By Ingrid Engeset, Solve Hov, Arnfinn Endal, Per-Anders Mortensen, Priscilla Paniagua, Bjørn Kristian Fiskvik Bache
During the last decades, it has become common practice in the Nordic countries to use dry deep mixing in soft clays with lime and cement in for example deep excavation pits in soft clay, or as a reinf
May 1, 2022
-
Evaluating Installation Disturbance of Helical Anchors in Clay from Field Vane Tests
By John Erikson, Alan J. Lutenegger, Nicholas Williams
"In order to evaluate the level of disturbance produced in clays during installation, a series of single-helix and multi-helix anchors were installed at a test site consisting of a stiff overconsolida
Jan 1, 2017
-
Effect of Axial Compression on Lateral Pile Response: Laterally Loaded Test Pile Comparison
By David S. Graham, Joseph D. Bailey, Paul J. Axtell, Michael K. Muchard
"Two instrumented test piles were simultaneously subjected to a static lateral load test by jacking the piles apart. One of the piles was loaded in axial compression via kentledge during the lateral l
Jan 1, 2017
-
Alternative Deep Basement Solutions for Built- Up Areas
By Abid Adekunte
"In recent years, developers have had to deal with complexities associated with numerous cases of deep basement construction in built-up areas. Design and construction of deep excavation support syste
Jan 1, 2015
-
Development of Environmental Double Pile (EDP) for Improvement of Contaminated Soft Ground
By Hyunsuk Yoon, Kiho Lee, Juhyng Lee, Younghoon Jung, Junboum Park
"The environmental double pile method is presented as a device to improve the engineering properties and to clean up contamination of low-permeability soil. This method is one of the novel technologie
Jan 1, 2005
-
Helical Piers/ Anchors in the Chicago Building Code
By Gary L. Seider, Dana A. Wesolek, Fred C. Schmednecht
"A new condominium project, The Atelier, developed by Pickus Companies located at the corner of Bryn Mawr and Sheridan in Chicago, IL required an earth retention system to protect the surrounding road
Jan 1, 2005
-
Environmentally Friendly Geothermal Piles At Keble College, Oxford, UK
By Tony P. Suckling
This paper presents a case study of a piling contract undertaken at Keble College in Oxford in the year 2001. Unusually, and for the first time in the United Kingdom, piles were successfully construct
Jan 1, 2002
-
Numerical Study On The Behavior Of Inclined Micropile
By Sepideh Damavandinejad Monfared
In recognition of the practicality of using inclined micropiles as elements for foundation support to resist static and seismic loading conditions, specifically in retrofitting projects, this study pr
-
Design And Analysis Of Cooling Tower Pile Foundations
By Michael W. Oakland
This paper summarizes the analysis and design of a pile foundation system for two 400 ft. diameter, 500 ft. high cooling tower using a detailed finite element analysis package. The cooling towers are
Jan 1, 2010
-
Determination Of Hydraulic Conductivity Of The Coralline Limestone Aquifer Of Jeddah, Saudi Arabia: Precautions And Recommendations For Deep Foundations
By Mohamed A. Eliwah
This paper deals with the determination of hydraulic conductivity of the coastal coralline limestone aquifer of Jeddah, Saudi Arabia. This coastal area has witnessed urban development and establishmen