    Measuring The Soil-Structure Interaction Of Laterally Loaded Piles

    By Muhannad T. Suleiman

    The design of deep foundations supporting heavy buildings, bridges, transmission lines, and highway structures, is governed by lateral loads in many cases. However, due to the use of empirical or semi

    Jan 1, 2011

  • DFI
    Performance Of Toe-Grouted Large Bored Pile In Sand-Gravel Formation Of Chiang Mai City, Northern Thailand

    By Narong Thasnanipan

    Performance of diameter 1.5 m toe-grouted bored pile founded at depth 44 m in sand-gravel formation of Chiang Mai City is presented in this paper. Toe grouting was applied by using tube-a-manchette me

    Jan 1, 2002

  • DFI
    Piles Lateral Force Capacity

    By Naim Noori Samie

    Lateral force rsistance of piles is analytically investigated by dividing the pile length to 3 segments. The first segment (Zone I) models the load eccentricity with respect to the soil and the pile-d

    Jan 1, 1996

  • DFI
    Analyses Of Dynamic Increasing Energy Load Test On Deep Foundations

    By Silvana B. Foá

    Results from full-scale loading tests showed the use of the dynamic increasing energy test (DIET) to verify the capacity of deep foundations. This method allows the measurement of dynamic resistance -

    Jan 1, 2002

  • DFI
    Active Engagement: An Overview of ACIP/DD Pile CPF Projects

    By Hannah Lezzoni, Morgan NeSmith

    The Augered Cast-in-Place and Drilled Displacement Pile Committee has historically been one of the most active and engaged DFI committees and has performed or spearheaded a number of research projects

    Nov 1, 2023

  • DFI
    Mindful Monitoring Of A Variable Excavation Support System

    By B. Philip Shull, Allen W. Cadden, Johanna M. Simon, Michael S. Senior

    A 670 linear meter (2,200 linear foot) large-diameter sanitary sewer interceptor installation at depths ranging from 3 to 10 m (10 to 30 ft) below existing grade in an area with a high water table req

  • DFI
    A Case Study In Hand-Dug Caissons ? Synopsis

    Caissons hand dug to a depth of about 100 feet were used to underpin three important structures at an industrial site in the State of Utah. The caisson shafts extended through 30 to 40 feet of coarse,

    Jan 1, 2010

  • DFI
    Effects Of Pile Driving In Saturated Soft Clay ? Synopsis

    By R. L. Wei

    The disturbing influences of pile driving on the surrounding soil mass, including the induced vibration, pore pressure and displacement of soil, were observed during the construction of pile foundatio

    Jan 1, 2010

  • DFI
    Geophysical Investigations Enhance Geologic Characterization In Support Of Pile Foundation Program

    By Mario Carnevale, Myles Danforth, Michael Oakland

    The cost and overall effectiveness of foundation design depends on a robust characterization of the subsurface geologic setting. It is common practice to formulate deep foundation design from subsurfa

  • DFI
    Application Of Large Diameter Pile Foundations To Factory Building

    By Wang Mingshu

    The pile foundation is a kind of advanced foundations in the filled or soft soil. In this paper, through the actural engineering of coal dressing plant of Western Opencast Coal in Fushun built on the

    Jan 1, 1991

  • DFI
    Underpinning A Deep Foundation ? A Case History ? Synopsis

    By M. Soranzo

    This paper presents a restoration operation of the load-bearing capacities of a deep foundation which did not satisfy the original design conditions. The operation was preceded by a series of tests ca

    Jan 1, 2010

  • DFI
    Correlations From In Situ Compression, Pull-Out & Lateral Load Tests On Piles ? Synopsis

    By Madhira R. Madhav

    In an alluvial deposit consisting of layers of sandy silt with clay and kankar nodules, driven cast in situ piles are provided. The piles end on a stiff bearing stratum To verify the available design

    Jan 1, 1996

  • DFI
    Interactive Encased Stone-Column Foundation - Synopsis

    By P. M. Deshpande

    An interactive short column system is evolved as alternative to deep foundation system in deep layers of marine clay, the interaction of encased stone column and marine clay carry load without causing

    Jan 1, 1996

  • DFI
    Slope Stabilization: Single Versus Staggered Piles

    By A. J. Metz, Roberto Nevarez

    One popular method to stabilize slopes is the use of deep foundation elements to support lateral loads from an unstable soil or rock mass. Drilled deep foundation elements are often selected due to lo

    Nov 1, 2023

  • DFI
    A Terminal Upgrade

    By W. Morgan NeSmith

    The city of Kansas City, Missouri, is replacing its original airport, con- structed in 1972 as a "drive-to-the- gate" facility, with a modern, single- terminal facility with just over 1 million sq ft

    Oct 1, 2022