SYNOPSIS Certain disadvantages associated with the use of Anfex have been raised on previous occasions. This interim investigation shows that by loading at lower pressures the sensitivity to initiation of Anfex can be improved. Associated with this is a reduction in velocity of detonation and charge density which should lead to more desirable fragmentation. The effect of lower loading pressure on other factors is also considered. INTRODUCTION Discussion at the Symposium on the use of Anfex in Underground Mining, conducted by the South African Institute of Mining and Metallurgy during May 1968 showed that there was considerable uncertainty and diversity of opinion on the characteristics of Anfex and its method of application. Some of the disadvantages associated with the use of Anfex were: Inadequate sensitivity to initiation; Excessive fragmentation of the rock and damage to the hanging and footwalls; Wastage as a result of blow-back; Poor water resistance. As a result of this, further investigations on the properties of Anfex have been carried out and, although these have not reached finality, it is considered that a progress review may be of interest and assistance to the mining industry. EXPERIMENTAL TECHNIQUE The work was carried out on a laboratory-scale where, for test purposes, the explosive was loaded into 1 in. (nominal) internal diameter steel pipes unless otherwise stated. Charging was conducted with a 1 in. (nominal) Schutte-Koerting eductor having a 0.2 in. internal diameter venturi nozzle, the Anfex being fed into the eductor from a conical hopper fitted directly above it. A 5 ft long copper loading tube with outside and internal diameters of 3/4 in. and 5/8 in., respectively, was fitted to the discharge end of the eductor. The remote end of the loading tube was inserted into the test pipe so that it was about 6 to 8 in. from the closed end of the pipe. The loading apparatus was withdrawn as the pipe filled, maintaining approximately the same stand-off distance throughout the operation. REVIEW Sensitivity to initiation Sensitivity of Anfex to initiation was found to deteriorate when the dynamic pressure of the air to the eductor was increased. This was attributed to increasing charge density and it was found that at a charge density of about 1.05 g/cm3, which
Dr C. M. van Staden (Fellow): Mr President, ladies and gentlemen, thank you very much for this opportunity to contribute to the paper by Dr Stander, and Messrs Henzen and Funke. First of all, my congratulations to Dr Stander on being re-elected President of the International Association of Water Pollution Research. We in South Africa are proud that this honour was again bestowed on our leading scientist in the field of water research. Furthermore, my congratulations to the authors of this paper. The growth of the pollution problem caused by acidic water discharged from abandoned collieries, is known to most of us. However, I am not aware of any case where an abandoned gold mine is directly discharging polluted underground water. I think it is also a debatable point as to what the quality of underground water being discharged from abandoned gold mines would be in the long run. Any reduction works on a gold mine which practises only fairly good housekeeping, should not cause any water pollution by cyanide. First of all, any cyanide solution before gold precipitation would be too valuable to lose. Secondly, the precipitated solution, which contains the cyanide, is used to pump slime to slimes dams. Any cyanide pollution that may occur at the slimes dam, must come from the top and, fortunately, the days when pen stock water was discharged directly from the top of dams into public streams, have gone. Run-off and seepage is usually acidic, thus decomposing the cyanide. The code of practice by the Chamber of Mines is quite clear on the point as to how the tops of dams should be secured, to prevent any process water or storm-water polluting public streams. The general standards are given on page three of the paper. To my knowledge, under certain circumstances a degree of relaxation can be given regarding the faecal coli count; namely a permissible count of 1 000 per 100 ml. I feel very strongly that research aimed at inhibiting the activity of acid-producing bacteria should be encouraged. Success in this field would be of great benefit to the mining industry. I am very thankful that the authors have mentioned vegetation of dumps as a method to combat water pollution, with the full awareness that the key objective in vegetating dumps is to prevent air pollution. A problem that I have not heard mentioned before and on which I would appreciate the views of the authors, is the pollution that may be caused by power-stations discharging
SYNOPSIS Heart rates, oral temperatures, shovels/min and number of 3/4 ton cars/hour trammed over distances of up to 350 ft were measured in samples of 6-10 miners, engaged in tram-shovelling, at 76°, 84°, 86°, and 89°F wet bulb temperatures in stopes in a mine. From the results it has been concluded that a man with an 'average' maximum oxygen intake capacity of about 2. 8 litres/min should be able to work: at 6 shovels/min, or 30 cars/shift per two men, at 76°-84°F; at 5 shovels/min, or 27 cars/shift per two men, at 86°F; and at 4 shovels/min, or 24 cars/shift per two men, at 89°F wet bulb air temperatures. INTRODUCTION A number of gold mines in South Africa still use tram-shovelling extensively. In this method of rock removal from the face of the stope, Bantu mine workers load rock into cars and tram the cars to a centre gulley where they are emptied. Previous studies from this Laboratory3 have shown that tram-shovelling is one of the most arduous tasks underground. The rate of energy expenditure is relatively high, being an oxygen consumption of about 1.4 litres/min over a period of some hours. In cool air conditions the upper limit to the rate of production of the well-motivated men employed on tram-shovelling has been shown1 to depend upon their capacities for physical work of an endurance nature (as measured by their maximum oxygen intakes). However, in hot conditions the factors which set the upper limit to the rate of production are different. They are primarily the ability of the body to maintain a heat balance between the rate of heat production, due to physical work, and the hot atmosphere, so that the men do not develop excessively high body temperatures8. In order to give mine managers guidance on the 'optimum' rate of production of Bantu mine workers engaged upon tram-shovelling under different temperature conditions underground a study was carried out in a mine. The number of shovels per minute and cars per hour were recorded and heart rates and oral temperatures were measured throughout the duration of the shift on samples of 6-10 Bantu mine workers in different air conditions. The results of the study are recorded in this paper and conclusions are drawn as to the number of shovels per minute and cars per hour which Bantu mine workers of 'average' maximum oxygen intake capacity should be able to produce at wet bulb air temperatures of between 76° and 89°F without either excessive fatigue or danger of heat illness.