Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    The Underwater Cut-Off At The Walter F. George Dam

    By Gianfranco Di Cicco

    Seepage problems were recorded for more then 40 years at the Walter F. George lock and dam. In 2001 the Mobile district of The U.S. Army Corps of Engineers turned to the installation of a 200 feet dee

    Jan 1, 2013

  • DFI
    Skin Friction Of Excavated Piles In Weathered Granite - Synopsis

    By K. K. S. Ho

    In Hong Kong the design of excavated piles in weathered granite has conventionally been based on a rule-of-thumb which relates the allowable base bearing capacity to the SPT N value, with no allowance

    Jan 1, 1996

  • DFI
    Stone Columns Through Construction Demolition Debris Fill

    By Lok M. Sharma

    Development of brownfields is of great interest in these days. Such fields are not easily adaptable for foundations of structures. The uncertainties in ground behavior present challenges of unpredic

    Jan 1, 2009

  • DFI
    Application Of Deep Foundation Structures To Great Bridges In Vietnam

    By Cau T. Bui

    Thanks to Doi-moi (renovation) policy, many great bridges were constructed in Vietnam to meet demands of her booming economy in the recent decade and deep foundation structures were the only alternati

    Jan 1, 2008

  • DFI
    Negative Drag Reduction On Spliced Piles - An Insitu Study - Synopsis

    By Gopal Ranjan

    An insitu prtotype study on precast driven spliced piles in soft marine clay deposit has been carried out to study negative drag. The drag is generated by loading the ambient clay. For reduction in ne

    Jan 1, 1996

  • DFI
    The Monroe St. Viaduct: A Case History Of MSE Vibro-Concrete Column Supported Embankment

    By Paul J. Lewis

    Replacement of the Monroe Street Viaduct in southwest Baltimore City, Maryland included transforming 240 feet of the south approach from a pile-supported multi-span bridge to a mechanically stabilized

    Jan 1, 2007

  • DFI
    Anaysis of Landslides and Slopes Stabilized Using One Row of Piles

    By Hamed Ardalan, Mohamed Ashour

    "CHAPTER 1INTRODUCTIONThe use of piles to stabilize active landslides or to prevent instability in currently stable slopes has become one of the most important innovative slope reinforcement technique

    Jan 1, 2013

  • DFI
    JFKIA - Post Grouted Drilled Shafts And Driven Piles - Update - Synopsis

    By Walter G. Brusey

    This paper describes a comprehensive pile test program conducted at John F. Kennedy International Airport (JFKIA) to evaluate pile types and design capacities ranging from 890 to 4450 KN (100 to 500 t

    Jan 1, 2000

  • DFI
    The Effects Of Heating And Cooling Energy Piles Under Working Load At Lambeth College, UK

    By Tony Amis

    There is very limited information relating to the potential impact of temperature cycles, outside the variation that occurs naturally, on the behaviour of foundation piles. Such thermal loading occurs

    Jan 1, 2008

  • DFI
    Mobilisation Of Skin Friction In Bored Piles In Hong Kong ? Introduction

    By R. A. Fraser

    Large diameter (1.0 to 2.5m) bored piles have been widely used to support buildings and elevated roadways in Hong Kong. Most of these piles are founded on a hard bearing stratum such as granitic or vo

    Jan 1, 2010

  • DFI
    Piled Rafts In Geotechnical Practice - An International Perspective

    By Michael W. Neill, O&apos

    The performance of foundations that combine the high bearing capacity of rafts (mats) with the settlement reduction capability of piles is described through a summary of 24 case histories. Structures

    Jan 1, 2003

  • DFI
    Seven Mile Dam Retrofit - A Global Challenge

    By Arvindh Gupta

    BC Hydro proposed to improve the stability of the existing Seven Mile Dam with 54 corrosion protected, re-stressable anchors comprising 92/0.6? strands each, in phase 2 of the program. Being globally

    Jan 1, 2004

  • DFI
    DFI Model Piledriving Contractor Proposal

    With respect to liability damages, claims and costs thereof relating to or ansmg out of contamination, special or non-special wastes, hazardous wastes or pollution in connection with the performance o

  • DFI
    Construction of Jacking Pits in Boston’s Central Artery/Tunnel Project

    By Arturo Ressi di Cervia

    "The Construction of the Thrust Pits for Jacking of the I-90 Tunnel for the Central Artery/Tunnel Project (Part of Contract No. C09A4) in Boston MA was nominated for DFI’s 2002 Outstanding Project Awa

    Jan 3, 2003

  • DFI
    Designed, Load Tested, Installed, And Integrity Tested ACIP Piles At Lovers' Key Site In Southwest Florida

    By Gregory A. Stephan

    A case history of design, prediction, instrumented static load tests on probe piles, installation monitoring, and integrity testing of production piles is presented. Based upon project-specific subsoi

    Jan 1, 1999

  • DFI
    Micropiles In Soft Florida Limestone

    By James D. Hussin

    The Florida limestone is a relatively soft rock which presents many challenges to engineers when designing deep foundations. One alternative is micropiles which have grown significantly from their ear

    Jan 1, 2003

  • DFI
    Interpretation Of Full Scale Horizontal Pile Loading Tests In Sand Analysis Of P-Y Curves

    By Ali Bouafia

    Five full-scale horizontal loading tests of piles carried out by the LCPC in France are interpreted in order to analyse P-Y load-transfer curves. The experimental piles are either bored or jacked into

    Jan 1, 2002

  • DFI
    Full-Scale Tests To Evaluate Lateral Pile Resistance At The Edge Of A Slope

    By Artak D. Mirzoyan

    Pile foundations near the edge of a slope are often required to resist lateral loads. This is particularly important for piles at abutments of bridges. However, very few full-scale tests are availab

    Jan 1, 2007

  • DFI
    Use Of High Capacity Grouted Tension Piles Installed Vibration Free And Soil Displacing

    By Peter de Kort

    Tunnels in urban areas generally require deep excavations in soils under the groundwater table. In The Netherlands uplift loads are generally taken by piles installed into dense sand layers, which are

    Jan 1, 2008

  • DFI
    Analysis Of Vertical Piles In Granular Soils Subjected To Static Lateral Loading - Synopsis

    By K. Rama Sarma

    Piles are frequently subjected to lateral forces and moments in addition to vertical forces and hence the piles have to be designed for both lateral loads as well as vertical loads. In the design of s

    Jan 1, 1996