Search Documents
Search Again
Search Again
Refine Search
Refine Search
-
Special Topic On Eurocode 7 And Standardization - Eurocode 7 - A European Geotechnical Design Code - The Eurocode System * The Objectives Of The Eurocodes
By Niels Krebs Ovesen
Close economic cooperation was established among the countries in western Europe during the seventies. As a consequence, among others, a need for harmonized technical specifications for civil engineer
Jan 1, 1994
-
Hand-Dug Caisson Foundation Of The International Trade Centre In Shenzhen ? Synopsis
By Y. G. Li
The design and construction of the hand-dug caisson pier foundation of the Shenzhen International Trade Centre are described in the paper. In addition discussions and inquires about the load-bearing c
Jan 1, 2010
-
Confinement Of Two Contaminated Sites In A Petrochemical Plant; Case History
By Raffaella Granata
The paper deals with the remediation of two areas formerly utilized for the disposal of hazardous wastes in a petrochemical plant. The works, designed on the basis of the criteria of maximum safety an
Jan 1, 2006
-
Installation Of Augered Cast-In-Place Piles - Equipment (f7778f75-6023-4133-8cd3-e733645bdcdf)
? Hollow Stem Auger ? Drill Bits ? Leads/Torque Arm ? Hydraulic Gearbox ? Hydraulic Power Unit ? Grout Pump ? Crawler Crane
Jan 1, 1997
-
Installation Of Bored Pile Casings Through An Asbestos Tip By Rotary Displacement
By Lewis Stansfield
A rotary displacement method was used to install permanent steel casings for bored piles through an asbestos tip. This method was chosen in preference to alternative driven systems because it was quie
Jan 1, 2000
-
Presentation #4 - Reflections On Pile Integrity Testing
By Joram M. Amir
Even when they are cased! [ ] In bored piles, as well as in drilled shafts, and in caissons too, defects will occur! [ ]
Jan 1, 2001
-
Extrapolation of Unit Side Resistance in Drilled Shaft Foundations Based on Bi-Directional Load Test Data
By Ramin Motamed, Joseph A. W. Toth
Evaluation of the capacity of large-diameter drilled shafts using current load test methods present challenges when considering the magnitude of loads required to fully mobilize their capacities. Ofte
Jan 1, 2018
-
Conventional And Box-Shaped Piled Rafts
By Heinz Brandl
Box-shaped pile and diaphragm wall foundations have proved suitable for transferring heavy loads of bridges, power plants, tanks, towers or other buildings in a concentrated form into the ground. The
Jan 1, 2002
-
Statnamic Load Testing Of Strain Instrumented Large Diameter Bored Shafts - Synopsis
By Matthew Janes
Statnamic load testing is becoming widely accepted as a method to quickly and economically determine the load-deflection behaviour and ultimate static resistance of high capacity deep foundations. Str
Jan 1, 1996
-
Experimental Investigation on the Lateral Load Capacity of Monopiles in Dense Sand
By Kenneth Gavin, Weichao Li, Paul Doherty
"The lateral load capacity is one of the most important issues to be considered in designing piles to resist berthing loads, ship impact forces and for monopiles used in the offshore wind sector. A nu
Jan 1, 2015
-
Designed, Dynamically Load Tested And Installed Pile Foundation In Southwest Florida - A Case History
By Christopher J. Pacitto
This paper presents a case history of an engineered, monitored, and tested program that provided an effective and satisfactory basis for the completion of pile foundations for Twin Dolphins 1 at La Pe
Jan 1, 2002
-
Contractual Pitfalls To Avoid With ACIP Piles
By William Babcock
Augered, Cast-In-Place (ACIP) piles can be an economical, reliable, versatile foundation system. They have also been a part of projects that were behind schedule and the subject of lawsuits. The ACIP
Jan 1, 1997
-
Effective Analysis Of Soil-Pile Interaction Under Dynamic Loads
By Inn-Joon Park
Major problems associated predicting soil-structure interaction behavior are based on the fact that soil is neither homogeneous nor elastic and soil properties are spatially variable. There also exist
Jan 1, 2002
-
Improvement Of Toe Resistance Of Drilled Shaft Foundations Using Smart Cells
By Mario A. Terceros Herrera, Mario Terceros Arce, Antonio Marinucci
A Smart Cell is a closed-type tip post-grouting device that is attached to the bottom of the steel reinforcement cage of a drilled shaft and is used to enhance performance and to reduce uncertainty th
-
A Pile-Supported Mat Foundation For A 27-Story Building In Milwaukee, Wisconsin (USA)
By Alan B. Wagner
The River Tower is a proposed 27-story condominium building in the heart of downtown Milwaukee, Wisconsin (USA). The tower will be over 100 m tall, and will have a ground area measuring 15 m by 40 m.
Jan 1, 2002
-
Maritime Structures
By D. Waite
The Chairman opened the session by wondering why so few papers on Maritime Structures had been received for this conference. Perhaps because the marine environment is so hostile and the access so diff
Jan 1, 1991
-
Stress Analysis Of Reinforced Earth Bridge Abutment ? Synopsis
By S. D. Zhang
The first reinforced earth railway bridge abutment in China has been successfully constructed of September, 1985 under the supervision of the Reinforced Earth Researth Group of Shanghai Institute of R
Jan 1, 2010
-
Comparison Of Dynamic And Static Methods Of Evaluating Static Pile Capacity - Synopsis
By Harpal Parmar
This paper evaluates dynamic methods of pile capacity prediction by comparing their results to static load test results. Dynamic and static pile load test data were assembled from four southeastern st
Jan 1, 1996
-
Dynamic Load Testing of Drilled Deep Foundations
By Paikowsky, Samuel G.
"Due to the way drilled deep foundations are being constructed, their structural integrity and geotechnical capacity are highly variable. Drop weight systems are increasingly being used to dynamically
Jan 1, 2015
-
Modelling For Consolidation Around The Pile Tip
By Emöke Imre
A point-symmetrical linear coupled consolidation model with displacement boundary condition is suggested for the description of the consolidation around the pile tip after pile penetration. Analytical
Jan 1, 2002