Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Analysis Of Vertical Piles In Granular Soils Subjected To Static Lateral Loading - Synopsis

    By K. Rama Sarma

    Piles are frequently subjected to lateral forces and moments in addition to vertical forces and hence the piles have to be designed for both lateral loads as well as vertical loads. In the design of s

    Jan 1, 1996

  • DFI
    Geotechnical Monitoring Of Deep Shoring Adjacent To Train Infrastructure

    By Jakub Szary

    Excavation and shoring adjacent to the above-grade Gilmore train station and elevated guideway was undertaken in 2019. A perimeter secant pile cut-off wall was constructed to a depth 37 m (121 ft) bel

    Sep 1, 2022

  • DFI
    Uncertainties Arising During Drilling And Performance Of Flight Auger - Cast Piles

    By F. M. Abdrabbo

    Flight auger bored piles are formed by screwing a continuous flight auger into the ground, and pumping cement/sand grout or concrete down the hollow stem of the auger as its withdrawn. The auger is dr

    Jan 1, 1993

  • DFI
    Methods Of Dewatering And Ground Water Control ? Synopsis

    By J. P. Powers

    Methods for dewatering and the control of ground water for construction and mining are discussed, including open pumping; predrainage with deep wells, wellpoints or other systems; cutoff or exclusion

    Jan 1, 2010

  • DFI
    Session 16 "Deep Mixing Method IV"

    By Mary Ellen Bruce

    Let me first address the issue of the wet grab samples. The wet grab samples that were attempted to take on the Central Artery were hindered by the fact that the way the mixing was being done was only

    Feb 10, 2003

  • DFI
    Estimating Axial Displacements Of Driven Piles In California Soils

    By Cem Akgüner

    The displacements of axially loaded single piles are analyzed with an approach based on elasticity. Young?s modulus and Poisson?s ratio of the soil encompassing a pile are the unknowns required as in

    Jan 1, 2008

  • DFI
    Evaluation Of Pile Load Test Results

    By Rasin Duzceer

    In this paper, the results of pile load test on 24 piles from twelve sites are presented. The pile load tests were performed on 14 driven and 10 bored piles of varying diameters and lengths installed

    Jan 1, 2002

  • DFI
    The Cosmopolitan Resort & Casino, Las Vegas, NV Specialty Foundation Work Under Extreme Conditions

    By Lawrence Piccagli

    This past spring of 2006, BENCOR installed the concrete reinforced diaphragm walls for the COSMOPOLITAN RESORT & CASINO in Las Vegas, Nevada. The project highlights include the excavation of approx. 3

    Jan 1, 2007

  • DFI
    Suction Bucket Installation

    By Avi Shonberg

    With the advancement of offshore wind farm projects towards deeper waters and larger wind turbine generators, founda- tion solutions other than the monopile have received increasing attention over the

    Jul 1, 2022

  • DFI
    Stability Analysis Of Jack-Up Rig At The Bohai Oil Field ? Introduction

    By H. Cheng

    The Bohai Oil Company has applied all together 11 jack-up oil drilling rigs (movable platforms) (1) which can be classified in terms of their forms of foundations into two types: the integ­ral mat and

    Jan 1, 2010

  • DFI
    Evaluation Of Degree Of Overconservatism In Api Shaft Friction Of Piles In Marine Sand Of The Arabian Gulf

    By Ahmed H. Bukhary, Naser A. Al-Shayea

    The objective is to assess the overconservatism in the parameters used for designing offshore piles. Methodology includes analysis of shaft friction data obtained from more than five different locatio

  • DFI
    Controlling Vibrations From Close-in Pile Driving

    By Patrick T, David K. Miller

    Driven piles are an effective and cost-efficient deep foundation method; however, when piles are driven near existing buildings and improvements, vibrations must be controlled to non-damaging levels.

  • DFI
    Effects Of Permanent And Temporary Loads On Allowable Bearing Capacity Of Piles Subjected To Nagative Skin Friction

    By Mohammad T. Izadi

    Piles are, often, used for transferring load from the super structure through soft consolidating strata onto relatively stiff uncompressible soils. Downward movement of the soft soil strata develops

    Jan 1, 2001

  • DFI
    Design And Installation Of Pressure-Grouted, Drilled Displacement Piles

    By Willie M. NeSmith

    The use of drilled (screwed) displacement piles is an emerging sector of the United States deep foundation industry. During installation of these systems, a Ko to Kp environment is created in the mate

    Jan 1, 2002

  • DFI
    Vertical Load Carrying Capacity Of Concrete Expanded Base Piles

    By Mustapha Zergoun

    This paper presents the results of load tests to assess the vertical load carrying capacity of concrete expanded base piles, or pressure injected footings, for various projects located near Vancouver,

    Jan 1, 2004

  • DFI
    Using Dynamic Pile Testing To Overcome Surprising Soil Variations

    By H. (Sam) Salem

    A site investigation for a wide and tall hotel building, in the San Juan Bay area, Puerto Rico, indicated a soil profile of silty clay on sand, soft and loose enough to require piled foundations. The

    Jan 1, 2008

  • DFI
    Effect of Free Standing Height on Rock Socketed Pile under Lateral Load

    By Prakash Annamalai Rangasamy, Muthukkumaran Kasinathan

    "Infrastructure development like elevated expressways, metro train and flyover are required proper foundation system to carry heavy traffic loads/significant lateral load, especially in the presence o

    Jan 1, 2015

  • DFI
    Comparison Between Statnamic And Static Load Testing Of Drilled Shafts In Varved Clay

    By Carl Ealy

    Static and STATNAMIC (STN) rapid load test (RLT) was performed on 3-drilled shafts. The purpose of the RLT part of the study was to obtain data in support of FHWA research on innovative load testing m

    Jan 1, 2002

  • DFI
    Behaviour Of Laterally-Loaded Piles Centrifugal And Numerical Modelling ? Synopsis

    By W. H. Craig

    Techniques have been developed for installing model piles into beds of soil under high sustained acceleration levels aboard a centrifuge. These piles have been subjected to static and/or cyclic latera

    Jan 1, 2010

  • DFI
    Determination Of The Load-Displacement Characteristics Of Single Pile In Soft Soil ? Synopsis

    By Z. C. Chen

    Based on the analysis of load test data of long floating piles in soft soil regions, the expressions of load-transfer function of pile shaft and tip for soft soils are presented in this paper, and the

    Jan 1, 2010