Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Hydraulic Drive Head Performance Curves For Prediction Of Helical Pile Capacity

    By Donald Deardorff

    Helical piles often rely on the final installation torque for ultimate capacity verification. When helical piles are designed using traditional bearing capacity equations for deep foundations and fie

  • DFI
    Calibration of the Gates Pile Driving Equation for LRFD in Louisiana

    By Glenn J. Rix, Eduardo Tavera, Raphael Siebenmann, Zhongjie Zhang, Robert C. Bachus, Jongwon Jung

    "The Louisiana Department of Transportation and Development (LADOTD) uses a variation of the FHWA-modified Gates equation to verify the nominal pile bearing resistance, typically on smaller projects w

    Jan 1, 2017

  • DFI
    Boston Waterfront Redevelopment: Re-use Of Existing Pier Piles To House Future Generations

    By John P. Briand III, Douglas J. Aghjayan, Robert E. Fosse

    This paper highlights the successful pile load testing program for the redevelopment of Pier One in East Boston, Massachusetts. Pier One is a 5.4-acre parcel on a dormant waterfront site used in the 1

  • DFI
    Alignment Control Of Drilling Rods For Jet Grouting By Integrated Microchips

    By Mousaab Majar, Nikolaus Schneider

    The technical challenges for accurate drilling positions increase with deep underground structures in inner city areas. Designed for jet grouting, specific sensors have been developed to record the al

    May 1, 2022

  • DFI
    Diaphragm Walls for Infrastructure Projects how to Deal with Complex Demands?

    By Franz-Werner Gerressen, Manfred Schoepf

    "Diaphragm walls are known as underground structural elements commonly used as retention systems for excavation pits and shafts and permanent foundation walls or elements. It can be anticipated that,

    Jan 1, 2015

  • DFI
    Jet Grouting Soft Clays for Tunnelling & Deep Excavations Design & Construction Issues

    By Marcelo Chuaqui

    We certainly have the data to back calculate it. I must admit that I haven't, at the moment my priority is not on what is the stiffness of the jet grout but is making sure that the jet grout is r

    Feb 10, 2003

  • DFI
    Brickworks Marketplace Ground Improvement, Adelaide

    By Andrew Middleton, Mark Wyatt

    "The Brickworks Marketplace Project is a significant shopping centre development in inner north west Adelaide constructed by Badge Constructions in 2014 and 2015. The site was a former brickworks with

    Jan 1, 1900

  • DFI
    Lateral Response of Pole on Engineered Driven Timber Pile Footing at Ararat Windfarm Terminal Station

    By Frank Albrecht, Brian McCarthy

    "The Ararat Terminal Station (ARTS) is located 190km to the north-west of Melbourne, approximately 1.7km to the north of Elmhurst Township in the Pyrenees region of western Victoria, Australia. The si

    Jan 1, 1900

  • DFI
    Construction Of Foundations For Zuari, Mandovi Railway Bridges In Goa ? Synopsis

    By N. V. Nayak

    Konkan Railway Project is one of the most ambitious railway construction projects in India, involving construction of a 760.km long, Broad Gauge (1676 mm), single track railway line, connecting Roha i

    Jan 1, 1996

  • DFI
    Historical Evolution Of The Micropile "Palo Radice" - Inception Of The Micropile

    By Pier Luigi Iovino

    As Technical Director of the Naples, Italy based Fondedile, a geotechnical construction firm specializing in static restoration of structures, Fernando Lizzi, Ing., devoted over 30 years to the pursui

    Jan 1, 2003

  • DFI
    Innovative SSP Design and Construction for a Complex Soil Remediation Project

    By Matthew C. Janes, Mark C. Spence

    "A former coal gasification site next to Rock Bay in Victoria, BC, Canada required a barrier to permit dewatering and excavation of the bay and surrounding property. The adjacent property owners had s

    Jan 1, 2016

  • DFI
    Cost Analysis Of Multiline Ring Anchor Systems For Offshore Wind Farm

    By Junho Lee, Leopoldo Bello, Mohammad Khan

    Multiline ring anchor (MRA) was developed as a cost-effective solution for securing floating offshore wind turbines (FOWTs) to the seabed. Since FOWTs are placed in arrays compared to conventional oil

  • DFI
    Heating And Cooling Structures With Steel Pile Foundations Closed Loop Standing Column Well Technology

    By Paul Suver

    The closed loop standing column well (CLSCW) system uses a closed circuit of water to develop the same thermal heat exchange characteristics that are achieved from traditional open circuit standing co

  • DFI
    Case Study: Large Diameter Helical Pile Foundation for High Voltage Transmission Towers in Soft Glacial Deposits

    By John Dunn, Matt Hawley, Kashif Butt, Nicholas Gura

    "This paper presents the results of a static load testing program completed on helical pile foundations for the replacement of high voltage transmission line tower structures. The foundations were par

    Jan 1, 2017

  • DFI
    The Keys to Success in Waikiki

    By Alison Savage, Michael Terry

    "For decades, the International Market Place (IMP) has been an icon in the heart of Waikiki in Honolulu, Hawaii. It was famous for Duke Kahanamoku’s restaurant where people flocked to hear Don Ho sing

    Jan 1, 2016

  • DFI
    Case Study: Feather River West Levee Program Cutoff Walls

    By Kyle R. Lackner, Jared P. Williams

    "The Sutter Butte Flood Control Agency initiated the Feather River West Levee (FRWL) Program in 2010 to bring 35 miles of levee along the Feather River into compliance with applicable Federal and Stat

    Jan 1, 2016

  • DFI
    Construction Of The Drilled Shaft Foundations For The Huey Long Mississippi River Bridge, New Orleans

    By Dan A. Brown

    The foundations at the Huey P. Long Bridge in New Orleans presented special challenges for construction due to the requirements for very deep drilled shafts in the Mississippi River beneath the existi

    Jan 1, 2010

  • DFI
    Numerical Study on the Behavior of Inclined Micropile (60b065bc-a615-421d-afa1-47c19339c8cb)

    By Sepideh Damavandinejad Monfared

    "In recognition of the practicality of using inclined micropiles as elements for foundation support to resist static and seismic loading conditions, specifically in retrofitting projects, this study p

    Jan 1, 2017

  • DFI
    Deep Foundation Underpinning Support For Fort Monroe, Virginia YMCA Historic Building Renovation

    By David C. Kraft

    Atlas Systems, Inc. (ASI) resistance type piers were used to underpin a 100 year old historic structure at Fort Monroe, Virginia. This 3-story structure with basement was underpinned with 155 steel tu

    Jan 1, 2002

  • DFI
    Development of Environmental Double Pile (EDP) for Improvement of Contaminated Soft Ground

    By Hyunsuk Yoon, Kiho Lee, Juhyng Lee, Younghoon Jung, Junboum Park

    "The environmental double pile method is presented as a device to improve the engineering properties and to clean up contamination of low-permeability soil. This method is one of the novel technologie

    Jan 1, 2005