Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Bearing Capacity Of Piles Determined By Field Tests ? Synopsis

    By D. M. Milovic

    On the basis of relatively large number of field load tests of piles, the determination of the ultimate bearing capacity have been studied. Using the load settlement curves and the results of the cone

    Jan 1, 2010

  • DFI
    Continuous Flight Auger Piles In The Blue Ridge: A Case Study Using Instrumentation In Pile Design

    By Jesse R. Jacobson

    A large casino complex in Cherokee, North Carolina recently underwent a $633 million expansion that involved substantial foundation challenges. The site is located in a valley on the southern edge of

    Jan 1, 2011

  • DFI
    Driven Pile Cost Comparison For Two Large Wisconsin Dot Bridge Projects

    By Van E. Komurka

    This paper presents a cost comparison of the driven pile foundations for two large Wisconsin Department of Transportation (?WisDOT?) projects in Milwaukee, Wisconsin: the Marquette Interchange South L

    Jan 1, 2009

  • DFI
    Formation Of Interlocking Jet Grout Columns At Large Depth

    By Chu E. Ho

    Jet grout column formation at large depths are prone to several uncertainties, such as inaccuracy in setting out boreholes, drilling deviation, soil variability and reduced jetting energy at the nozzl

    Jan 1, 2008

  • DFI
    Drilled Shaft Side Shear Capacity In Compressible Materials What Influences Capacity?

    By J. A. Hayes

    For over a decade the Osterberg Load Cell has been successfully used to determine the shear capacities of drilled shafts. Since the test method measures side shear directly, analytical complications d

    Jan 1, 2003

  • DFI
    Settelement Of A Piled-Raft Foundation Considering Lateral Pile Resistance

    By Helen S. W. Chow

    The use of piled raft foundations for tall buildings has been increasing in this decade as it is an economical alternative to conventional piled foundations. Piled rafts are composite structures compr

    Jan 1, 2006

  • DFI
    Resistance Factors For Lateral Design Of Drilled Shafts Supporting Sound Walls

    By Ke Yang

    Drilled shafts are widely used as foundation system for sound walls to resist lateral loads. The design method based on the ultimate lateral capacity, such as Broms method, is often used for sound wal

    Jan 1, 2007

  • DFI
    Real Time Validation of Driven Cast In-Situ Piles

    By Derek Egan

    "Abstract Construction clients want their foundation solutions to be right first time, every time; but it is often the geotechnical contractor who carries the most risk in achieving this. Robust valid

    Jan 1, 2014

  • DFI
    A Contribution To Studies Of Piles Under Dynamic Loads - Synopsis

    By R. J. Folic

    Investigations of the vibrations of a pile in soil are performed on a dynamic model in the form of a prismatic bar of finite axial and flexural stifnesses with a discrete mass at its free end represen

    Jan 1, 2010

  • DFI
    Advances In Seismic Design Considering Soil- Structure Interaction

    By Y. C. Han

    The advances in seismic design considering soil-structure interaction or soil-pile-structure interaction are described using a substructure approach. The nonlinearity of soil is considered approximate

    Jan 1, 2010

  • DFI
    Displacement And Pore Pressure Monitoring During Installation Of Drilled Displacement Piles

    By Lisa M. Splitter

    Drilled displacement piles were constructed as the foundation for a proposed 10-story building in San Francisco, California. At the study location, the stratigraphy consists of 14 to 21 feet of fill

    Jan 1, 2009

  • DFI
    Bending Strength Of Threaded Micropile Connections

    By Steven R. Musselman

    The bending strength and flexural stiffness of a micropile at its threaded connection is less than its intact strength and may fail due to thread slippage or by fracture through the pin (reduced cross

    Jan 1, 2007

  • DFI
    Ground Vibrations from Pile and Sheet Pile Driving Part 1 — Building Damage

    By K. Rainer Massarsch, Bengt H. Fellenius

    "Abstract Vibrations generated during the driving of piles or sheet piles can affect buildings or installations in the ground. However, observed building damage is not always caused directly by dynami

    Jan 1, 2014

  • DFI
    Development Of Design Practice For Piles In Stiff Glacial Till

    By Kenneth Gavin

    Design practice for piles installed in Irish glacial till has developed in an ad-hoc manner, based on the results of un-instrumented load tests. This had led to designers using similar design paramete

    Jan 1, 2009

  • DFI
    Installation Of Augered Cast-In-Place Piles - Equipment (1ca07ced-58e8-4100-8369-c2eebb984ebc)

    ? Hollow Stem Auger ? Drill Bits ? Leads/Torque Arm ? Hydraulic Gearbox ? Hydraulic Power Unit ? Grout Pump ? Crawler Crane

    Jan 1, 2000

  • DFI
    Prediction Of Ultimate Bearing Capacity Of Steel Pipe Pile By Wave Equation ? Synopsis

    By R. G. Shen

    The relation curve of strain and acceleration is presented in this paper. The steel pipe pile of 609.6 mm in external diameter driven by IDH-45 diesel motor hammer on the esturial shoal of Yangtze Riv

    Jan 1, 2010

  • DFI
    2D And 3D Analysis Of New Austrian Tunnelling Method

    By G. R. Dasari

    New Austrian Tunnelling Method (NATM) has been analysed by Finite Element method in two and three dimensions by Strain Dependant Modified Cam Clay (SDMCC) Model. The effects of construction sequence,

    Jan 1, 1996

  • DFI
    An Approximate Nonlinear Analysis Of Vertically Loaded Piled Rafts In Layered Soils

    By Seung-hoon Lee

    The use of piled raft foundations has been considered as an economical alternative to conventional piled foundations because a portion of the applied load is carried by the raft in the design of piled

    Jan 1, 2008

  • DFI
    Ultimate Uplift Capacity Of Piles And Pile Groups In Granular Soil

    By B. M. Das

    Laboratory model test results for the ultimate uplift capacity of rough rigid single and group piles embedded in sand have been presented. Model tests on single piles were conducted in loose, medium,

    Jan 1, 1989

  • DFI
    Advantages And Limitation Of Integrity Tests For Large Diameter Bored Piles In Bangkok Subsoil

    By Narong Thasnanipan

    In Bangkok due to the prevailing condition of subsoil (existence of considerably weak stratum at top part) deep-seated large diameter bored piles of over 50 m depth with 0.8 -1.8m in diameter have bee

    Jan 1, 2004