Evaluation Of Pile Load Test Results
By Rasin Duzceer
In this paper, the results of pile load test on 24 piles from twelve sites are presented. The pile load tests were performed on 14 driven and 10 bored piles of varying diameters and lengths installed
Jan 1, 2002
-
Mobilisation Of Skin Friction In Bored Piles In Hong Kong ? Introduction
By R. A. Fraser
Large diameter (1.0 to 2.5m) bored piles have been widely used to support buildings and elevated roadways in Hong Kong. Most of these piles are founded on a hard bearing stratum such as granitic or vo
Jan 1, 2010
-
Permanent Soil Nail Earth Retention System, Stanley Hall Replacement Project, UC Berkeley
By Pirooz Barar
The new Stanley Hall building will house the center for bio-engineering and technology research for the UC Berkeley campus. The structure is located at the northeast part of campus, adjacent to Donne
Jan 1, 2004
-
Granular Pile For Ground Improvement ? Synopsis
By G. Ranjan
The designers and the practicing engineers have started using latest and cost effective techniques of ground improvements which utilise the weak and poor sub-soil deposits efficiently for the civil en
Jan 1, 2010
-
Determining The End Bearing Capacity Of Steel Tube Piles Driven To Glacial Till In The Montréal Area Of Canada
By Richard Deakin
This case study describes aspects of the design of bridge foundations using 320mm diameter steel tube piles in the vicinity of Montréal, Canada. In this area, these piles are a very commonly used and
Jan 1, 2011
-
Computation Of The Load/Settlement Behaviour Of HP-Bearing Piles - 1. Introduction
By E. E. De Beer
This paper describes a method for the determination of the settlement of an individual H-bearing pile, based on the results of CPT-tests. As implied by the nature of the problem, no analysis perform
Jan 1, 1987
-
Design Of Pile Foundations For The Sand Creek Byway, Sandpoint, Idaho
By Dean E. Harris
The realignment of U.S. Highway 95 in Sandpoint, Idaho, is being designed on a site underlain by glaciolacustrine soil that includes very thick deposits of soft, sensitive clay to estimated depths of
Jan 1, 2003
-
Bearing Capacity Of Long Piles Driven Into Soft Soil ? Synopsis
By F. Z. Suo
Baoahan Iron and Steel Complex is situated at lower beaches of the Yangtze River. The subsoils 50~70 M below the surface is a deposite of Yangtze River delta, consisting mainly of weak silty clay and
Jan 1, 2010
-
Appropriate Field Measurements For Testing Capacity-Prediction Methods For Piles Installed By Vibration - Introduction
By Michael W. Neill, O&apos
The engineering profession generally does not accept vibro-driven piles as bearing piles unless their capacities can be verified by restriking with an impact hammer, which significantly reduces the ec
Jan 1, 1989
-
Drilled Pier Foundations In Downtown Seattle - Introduction
By Thomas M. Gurtowski
This paper presents a summary of allowable bearing pressures and skin friction values that have been used to design drilled pier foundations for support of high-rise structures in downtown Seattle, Wa
Jan 1, 1990
-
High Capacity Piles In The Hamilton Bayfront Area
By C. D. Thompson
Pile load test programs were carried out in 1984 and 1985 at Stelco's and Dofasco's Steel Making Plants in the Hamilton Bayfront area. 323.9 mm outside diameter by 9.5 mm wall thickness Grad
Jan 1, 1987
-
Kentucky Route 9 - Licking Pike Widening Design Build Slope Stabilization
By Frederick W. Slack
This paper will discuss the inherent value engineering associated with the design and construction of approximately 184,000 SF of anchored tieback wall, installed as part of the widening and drainage
Jan 1, 2003
-
Wick Drains into the unknown
By Brian McGlynn
There are many factors that can result in a site characterization being limited. For example, a client may undervalue the importance of a good geotechnical report, or an owner may feel that it would t
May 1, 2023
-
Capacity Prediction Vs. Performance Of Driven Pre-Cast Pre-Stressed Concrete Piles In Chesapeake, Virginia
By Emad Farouz
This paper compares the predicted axial capacity of driven Pre-cast Pre-stressed Concrete (PPC) piles for the Lake Gaston Water Treatment Plant (LGWTP) using several design methodologies versus the ax
Jan 1, 2007
-
Pile Foundations For Algiers New Airport Terminal
By Ramdane Bahar
The new Algiers airport building is a reinforced concrete building of more than 80 thousand square meters of floor slabs. It is located at Dar-EI-Beida, near the old passenger terminal, about 20 km ea
Jan 1, 2002
-
Design Of The Marine Foundations For The Skyway Project Of The San Francisco Oakland Bay Bridge
By Gerry Houlahan
The east span of the 3.5 km long SF-Oakland Bay Bridge is supported by different types of foundations along its span. Starting from the west, its first 460 m section comprising twin concrete box-girde
Jan 1, 2013
-
RResearch On Dynamic Inspection Of Prototype Models Of Reinforced Concrete Piles
By Xuhui
Pile foundations are underground projects which are carried out under complicated site conditions, so it is difficult to summarize their characteristic patterns from the everchanging practical pile fo
Jan 1, 1991
-
Settlement Control Of A Road Embankment Using Vertical Drains
By Wei Tu
A grade separation was required to allow uninterrupted traffic crossing for a busy rail spur and a county road. The grade separation was achieved by creating a 30-foot (9-meter) high embankment that
Jan 1, 2009
-
Design And Performance Of Helical Screw Piles In Collapsible And Expansive Soils In Arid Regions Of The United States
By David R. Black
Foundation problems due to collapsible and expansive soils are well known throughout the arid western United States. Millions of dollars are spent annually to counteract the effects of such soils for
Jan 1, 2002
-
Experiences From A Large Scale Driven Precast Piling Project In India
By Rajesh A. Vaidya
A large scale piling work is undertaken in India for an important fast track industrial project. Thousands of solid square precast concrete piles are driven to depths of around 50m. Soils encountere
Jan 1, 2007