Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • SME-ICGCM
    Anchorage Pull Testing for Fully Grouted Roof Bolts

    By Chris Mark

    Fully-grouted roof bolts comprise more than 80% of the primary roof supports used in U.S. coal mines. However, nearly 1,500 MSHA reportable, non-injury roof falls occur each year, and most of these ar

    Jan 1, 2002

  • SME-ICGCM
    Scale Model Studies To Investigate The Effects Of Various Stressfields On The Stability Of Pillars Between Mine Roadways (359d84ec-978c-4bf2-a810-72bdf384bacc)

    By K. Goshtasbi Goharizi

    This paper discusses experimental results of physical scale models employed to study the stability of a pillar between rectangular roadways. A programme of laboratory investigations utilising a bi-axi

    Jan 1, 1992

  • SME-ICGCM
    Stereological Sampling And Analysis For Characterizing Discontinuous Rock Masses

    By J. K. Owens

    As part of a larger research effort focused on ground control, the U.S. Bureau of Mines is currently evaluating the effectiveness of using stereological analysis for characterizing mine roof strata. I

    Jan 1, 1994

  • SME-ICGCM
    A Simplified Two-Dimensional Analysis Of The Roof-Pillar-Floor Interaction Problem In Coal Mines

    A two-dimensional time-dependent analysis of a overburden-coal pillar-weak floor strata interaction problem is presented as a beam model consisting of a composite roof beam resting on multiple elastic

    Jan 1, 1988

  • SME-ICGCM
    Evaluation of Pillar Recovery in Southern West Virginia (0e64fb3d-0c07-4638-b455-a16004535ca1)

    By Chris Mark

    Pillar recovery continues to be a significant ground control hazard. During the past decade, 10 miners were killed during pillar extraction operations in southern West Virginia. Studies conducted duri

    Jan 1, 2002

  • SME-ICGCM
    Investigation into the Extent and Mechanisms of Gloving and Un-mixed Resin in Fully Encapsulated Roof Bolts

    Effective strata control, utilising fully encapsulated roof bolts, is dependent on the installed quality of the reinforcement elements. One mechanism by which fully encapsulated roof bolts may become

    Jan 1, 2003

  • SME-ICGCM
    The Use Of Geologic Modeling In The Prediction Of Adverse Roof Conditions

    By Edward S. Custer

    Recent investigations of mine roof falls have demonstrated that roof failures are generally associated with geologic conditions. The roof falls can be predicted by using the techniques of depositional

    Jan 1, 1981

  • SME-ICGCM
    Simplified Pre-and Post-Processing Technique for Performing Finite-element Analyses of Deep Underground Mines (4c70a887-9438-4254-8d3e-3283730c59e0)

    By Marc T. Filigenzi

    Two of the major ground control safety issues confronting underground mine operations today are shaft pillar stability and the failure of rock around active mine openings. Failure of a mine shaft can

    Jan 1, 1997

  • SME-ICGCM
    Effects of Panel Mining Sequence and Retreat Direction on the Roof Stability of Longwall Headgate Entries

    By Jinsheng Chen

    The major functions of longwall headgate entries are to provide access ways to the outby submains or mains for coal transportation and to the longwall face for fresh air and for transporting men and m

    Jan 1, 1998

  • SME-ICGCM
    Rock Bursts In Human Collieries

    By Guang Ping Cui

    In this paper the imminent relationship between rock burst and its phenomenon with normal rock pressure and its appearance, as well as the factors of one changing into another have been analyzed. Base

    Jan 1, 1984

  • SME-ICGCM
    Roof Instability of Longwall Face at Ikeshima Colliery

    By Kikro Matsui

    Longwall mining 1s more productive in comparison to other methods but requires particular conditions for its effective use This paper relates to longwall roof instability at Ikeshima Colliery In order

    Jan 1, 1997

  • SME-ICGCM
    Study On The High-Pressure Grouting Of The Overburden For Subsidence Control

    By W. J. Guo

    Overburden movement as a result of longwall mining can be classified into, in ascending order, caving zone, fractured zone, and bending zone. Operation experience and laboratory research have demonstr

    Jan 1, 1994

  • SME-ICGCM
    The Integration Of Geology And Engineering In Ground Control And Mine Planning For A Multi-Level Underground Limestone Quarry

    By D. Newman

    An underground limestone quarry, developed in the 1940's, transitioned from a surface quarry to an underground room-and-pillar operation. The quarry expanded to a second underground level when th

    Jan 1, 2001

  • SME-ICGCM
    Successful Application Of Hydraulic Fracturing To Control Windblast Hazard At Moonee Colliery, NSW, Australia

    By Ken Mills

    This paper describes the first successful use of hydraulic fracturing to induce caving events "on demand" in Australia. Moonee Colliery operate a longwall immediately below a thick conglomerate strata

    Jan 1, 2000

  • SME-ICGCM
    Entry Design For Optimum Stability In A Multi-Seam Environment

    By Mohummad Akram

    Statistical analysis of multi-seam mining case studies demonstrated that geologic structure and lithological type and sequencing were predominant factors in entry failures. Finite element analysis was

    Jan 1, 1993

  • SME-ICGCM
    Mapping and Application of Roof Joint Patterns for Ground Control inAn Illinois Mine

    By Kenny D. Basnett

    An analysis of the Roof Falls Data Base (RFDB) for underground coal mines in Illinois for the period 2004?2008 indicated that about 80% of the roof falls occur at intersections and are associated with

    Jan 1, 2011

  • SME-ICGCM
    Analysis Of Longwell Shields And Their Interaction With Surrounding Strata In A Deep Coal Mine

    By Duk-Won Park

    A vast majority of the operating longwall sections use shield-type face supports to provide ground control in the United States. As a co-operative research program between the University of Alabama (U

    Jan 1, 1992

  • SME-ICGCM
    Intersection Stability and Tensioned Bolting

    By Yunqing Zhang

    Roof failure occurs much more frequently at intersections than entries and crosscuts. Using a commercial finite element package, four-way and three-way intersections reinforced with the tensioned bolt

    Jan 1, 2003

  • SME-ICGCM
    Developments in Improving the Standard of Installation and Bond Strength of Full Column Resin Roofbolts

    By Peter Altounyan

    Goedehoop Colliery in the Witbank Coalfield of South Africa produces some 8 million tonnes of coal from fully mechanised room and pillar mining methods, using resin anchored bolts as roof support. Inv

    Jan 1, 2003

  • SME-ICGCM
    In-Situ Pillar Strength Determination for Two-Entry Longwall Gates

    By H. N. Maleki

    Extensive measurements and underground observations in three Western U. S. coal mines are integrated in this paper to determine in-situ pillar load-deformation characteristics for narrow (30 it wide,

    Jan 1, 1988