    Analysis of Three Axial Load Tests on Large Bored Grouted Deep Foundations

    By Hayel M. El-Naggar, Marawan M. Shahien

    "Large capacity piles are important type of foundation elements that are needed in case of high column loads such as in tall buildings with large span between columns. In many projects, especially if

    Jan 1, 2017

  • DFI
    USTA Geoseismic and Foundation Design Challenges

    By Athena C. Denivo, Pablo V. Lopez, Sissy Nikolaou, Alfred H. Brand, Ahmad Rahimian, Rudivien G. Josef

    "The United States Tennis Association (USTA) Billie Jean King National Tennis Center (BJKNTC) site is located in the northeastern portion of the Flushing Meadows Corona Park area of Queens, N.Y. The s

    Jan 1, 2015

  • DFI
    Studies On The Use Of Dcis Piles For Mitigating Liquefaction Of Soils

    By Viswanadham B. V. S., Babu K. V

    Many refineries are in the process of revamping and expanding their existing facilities. Most of the refineries are located in coastal areas due to ease of transportation and storage of crude oil. Con

    Sep 1, 2022

  • DFI
    Strength Behavior of Soilcrete Improved by Cement and Metakaolin

    By Guo Qian, Du Guangyin, Deng Yongfeng, Liu Songyu, Wang Ningping

    "Metakaolin (MK) can efficiently enhance the strength and the impermeability of concretes and mortars. However, it has rarely been attempted in admixtures of cement-stabilized soils until presently. A

    Jan 1, 2015

  • DFI
    Performance Monitoring of Mixed Ground Working Platform for a CCR Surface Impoundment

    By Ali Ebrahimi, Jeremy M. Gasser, Cuneyt Gokmen, Paul J. Sabatini, Roneet Das, William Tanner, Amir Ahmadipur

    There are safety concerns related to operation of heavy equipment over coal combustion residual (CCR) impoundments during construction of the impoundment closure programs. As part of a pilot study pri

    Jan 1, 2019

  • DFI
    Stability Analysis Of A Rubble Mound Breakwater Resting On The Weak Seabed By 2D Finite Element Modelling

    By Vijaya R, Boominathan A

    The design of a rubble mound breakwater resting on a problematic seabed is quite challenging and expensive. In the present study, stage-wise construction of a typical section of the breakwater for a p

    Sep 1, 2022

  • DFI
    Field and Laboratory Mix Trials for a Deep Soil/Cement/Bentonite Cut-Off Wall Using CSM Equipment

    By Russell J. Denny

    "A 25m deep cut-off wall is required for environmental remediation of a Former Chlor-Alkali Plant. Extensive trials were conducted to verify the effectiveness of the mixes proposed, with the requireme

    Jan 1, 2015

  • DFI
    PSC Piles Overcome Challenges for $650m Power Plant

    By Tim Siegel, III Fondren, Billy Camp

    "INTRODUCTIONThe new $650 million power block at Santee Cooper’s Cross Generating Station in Cross, South Carolina is being constructed on driven pre-stressed concrete (PSC) piles. S&ME, as geotechnic

    Jan 1, 2004

  • DFI
    Errata (5268ac87-18a9-458e-b334-4f72060324e3)

    Volume 1 pages 665-671 Title should read as Dynamic pile testing of H-piles at HDB sites J.Wei, Y. S. Heng, C. S. Lok, M. K.Chong Housing and Development Board, Singapore 'tons'

    Jan 1, 1994

  • DFI
    Simplified Model for Increased Lateral Resistance of Deep Foundations Using Soil Mixing

    By Hubert Law, Dan A. Brown, Kyle M. Rollins

    "Soil mixing and jet grouting provide a means to significantly increase the lateral resistance of pile group foundations with relatively little investment of time, effort, and expense compared to the

    Jan 1, 2015

  • DFI
    Foundation Reuse: Overcoming Resistance

    By Sara Anderson, Rachel Nicholls, Tim Chapman, Janice Windle

    "In city center sites around the world, and in particular in London, foundation reuse is becoming increasingly widespread as the ground is filled with detritus from previous developments. This paper s

    Jan 1, 2005

  • DFI
    Dynamic Pile Testing for the Five Mates Bridge

    By Jonathan G. Cannon

    "This paper will describe dynamic pile testing conducted during installation of driven octagonal precast prestressed concrete piles used as the foundation for this bridge. The piles were long and henc

    Jan 1, 1900

  • DFI
    ACIP Pile Performance and Installation in the Northeastern United States

    By Jr NeSmith

    "Augered-cast-in-place (ACIP) pile installation technology has matured extensively since the first auger, pressure grouted pile was patented in 1959. The current technology allows for successful pile

    Jan 1, 2016

  • DFI
    Urban Challenges In Design, Co-Ordination And Construction Of Deep Foundations And Retaining Walls

    By Pawan L. Sethi

    Design and construction of deep foundations and basements is increasingly becoming more complex, as the density and frequency of urban development increases. This growth brings various associated chal

    Nov 1, 2022

  • DFI
    Deep Foundation Ground Anchors In The Wind Energy Industry - Current Status Of Design And Construction Practices And Introduction Of A Patented System To Improve Foundation Performance

    By Josef K. Alter

    Long-term performance and behavior of post-tensioned ground anchors subjected to axial cyclic loading constitutes an important aspect of the stability, reliability and overall performance of wind turb

    Jan 1, 2010

  • DFI
    Dynamic Characterization Of Drilled Shafts On Doremus Avenue Bridge

    By Martina Balic

    Dynamic properties of the drilled shaft foundations supporting Doremus Avenue Bridge were determined by forced vibration testing. The main objectives of the substructure testing at Doremus Avenue Brid

    Jan 1, 2004

  • DFI
    Case History – San Francisco 49ers NFL Stadium Pile Foundations Santa Clara, California

    By Scott A. Walker, Gabriel J. Alcantar, Brian Zuckerman, Ramin Golesorkhi

    "The stadium development consists of construction of a 68,500-seat, open-air NFL football stadium for the San Francisco 49ers. The main structure will consist of a 7-story above grade steel structure

    Jan 1, 2015

  • DFI
    Determination Of Thermal Conductivity Of Coarse-Grained Soils

    By Madhu. P, Srinivas. K

    Measurement of thermal properties like thermal conductivity, thermal resistivity, heat capacity and thermal diffusivity for materials, it plays a crucial role in a wide range of various civil and elec

    Sep 1, 2022

  • DFI
    A Novel Method For Assessing The Reuse Of Under Reamed Piles As Part Of The Southbank Place Project

    By Stuart Hardy, Xiangbo Qiu

    The South Bank Place project comprised the redevelopment of the iconic Shell Corporation headquarters in Waterloo, located on the Southbank of the River Thames in central London. The site was original

    May 1, 2022

  • DFI
    Dealing with Complexities Associated with the Application of Bored Pile Retaining Walls in Urban Developments

    By Abid Adekunte

    "Engineers and developers have witnessed the growing popularity of deep basement structures as components of urban commercial and residential developments. This is often attributed to inadequate surfa