Search Documents
Search Again
Search Again
Refine Search
Refine Search
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
-
Multiple Foundation Types For Bridges Over The Same Coal MineBy Kenneth M. Berrry
A unique situation has developed at an abandoned coal mine in St. Clair County, Illinois. Subsidence features have been observed at the ground surface over the mine including settlement of a pair of b
Jan 1, 2001
-
Field Tests Of Soft Clay Stabilized By Stone Columns In Coastal Areas In China (325b7cc0-aff5-4a88-9f69-cd3dc2f57f1d)By Han Jie
The results of full scale plate load tests on stone columns on soft clay in coastal areas are presented in this paper. Four load tests were made, two of which were performed on the ground treated with
Jan 1, 1991
-
The Effects Of A Direct Electrical Current On The a Value Of Metallic Piles In Clay - SynopsisBy Stephen T. Bloomer
The application of a direct current electrical potential between a metallic pile and a fine grained soil results in an almost instantaneous change in the magnitude of the forces acting on the pile.
Jan 1, 1996
-
Micro-Biological Attack On Deep Foundation ConcreteBy Piotr D. Moncarz
As major urban areas begin to run out of "good-terrain" for their expansion, they begin to claim high water-table areas within or adjacent to water fronts or swamps. Similarly, major infrastructure pr
Jan 1, 2002
-
Woodrow Wilson Bridge CofferdamsBy Roderic A. Ellman
The new Woodrow Wilson Bridge (WWB) will replace the existing bridge over the Potomac River to connect Alexandria, Virginia to Prince Georges County, Maryland. The new WWB will extend approximately 1.
Jan 1, 2005
-
Remedial Work On Large Pile Deviation In The Very Thick Marine Swamp Clay DepositBy Wanchai Teparaksa
Pile deviation generally can happen after installation of driven pile particularly in soft soil layers. In this case study, all 242 diameter 0.8 m spun piles were deviated from 20 to 820 mm. The large
Jan 1, 2002
-
Unknown Bridge Foundation Investigation With Nondestructive Methods ?The Combined Parallel Seismic/Seismic Cone Penetrometer MethodBy Larry D. Olson
Research, hardware development, and field testing have been conducted on systems to allow easy and accurate determination of both foundation tip depth as well as the properties of the soils at and abo
Jan 1, 2007
-
Stone Columns At Trenton Water Treatment Facility - Suitable Alternative To Remove And Replace For Mat FoundationBy Darrell Wilder
The Trenton Water Treatment Facility in Trenton, New Jersey, is expanding to upgrade existing facilities and to meet the increasing demands of the public. The facility sits uncomfortably between the
Jan 1, 2008
-
Sustainability Simply Makes SenseBy Gerald Verbeek
There are certain concepts that seem to invite responses from some, including some in the foundation industry and even some within DFI, that are at best surprising. Business owners and their employees
Nov 1, 2022
-
Design Of Well Cap, Pier And Well Steiming At The Junction Using Strut-And-Tie Model - SynopsisPier, well cap and steining junction is a complicated 3-d re-ion. The prevalent design procedure for the pier, well cap and steining in isolated manner is not rational. In absence of an integrated app
Jan 1, 1996
-
Foundation Code8 And Linit 8tatb Partial Factoring - SynopsisBy W. G. K. Fleming
The codification of foundation design and construction is a subject of extensive discussion in Europe and all current code proposals are based on limit state partial factoring. For simplicity, it is c
Jan 1, 1996
-
A General Formula To Determine The Allowable Pile Bearing Capacity In Case Of Negative Skin Friction ? SummaryBy Cornelis Van Der Veen
Foundation piles, partly passing through unconsolidated compressible layers, suffer a downward drag that is called negative skin friction. The negative skin friction depends on the movement of the sur
Jan 1, 2010
-
Design Criteria Of Dynamic Consolidation ? SynopsisBy Z. Q. Wang
The author is trying to clarify the existing problems in designing and laying out dynamic consolidation for soft ground improvement. Field testings and observations including vibrational parameters, p
Jan 1, 2010
-
A History Of The Use Of ACIP Piles For Major Projects In AtlantaBy Willie M. NeSmith
In the Metropolitan Atlanta Area today, augered, cast-in-place (ACIP) piles will be considered on most projects where deep foundation support is required. ACIP piles were first used in Atlanta in the
Jan 1, 2003
-
Probabilistic Development Of Load And Resistance Factor Design For Driven Pipe Piles In Sands: Lessons LearnedBy K. C. Foye
Use of load and resistance factor design (LRFD) of foundations is growing, from offshore applications to bridge applications and beyond. The development of load and resistance factors for design has
Jan 1, 2008
-
Performance Of Toe-Grouted Large Bored Pile In Sand-Gravel Formation Of Chiang Mai City, Northern ThailandBy Narong Thasnanipan
Performance of diameter 1.5 m toe-grouted bored pile founded at depth 44 m in sand-gravel formation of Chiang Mai City is presented in this paper. Toe grouting was applied by using tube-a-manchette me
Jan 1, 2002
-
Fundamental Issues Of Displacement Auger Piling: The European PerspectiveBy Maurice Bottiau
When dealing with displacement auger piling, some general and fundamental issues have to be considered, irrespective of the system. More than with other pile types, the interplay between the soil cond
Jan 1, 2003
-
Berth Deepening A Three Decade Old Wharf Structure For The Next Generation Of Container ShipsBy Bill Paparis
The thirty year old wharf structures at the Port Authority of New York & New Jersey?s Port Elizabeth Marine Terminal are being modernized for the next generation of Post-Panamax container ships, which
Jan 1, 2013
-
Piles Lateral Force CapacityBy Naim Noori Samie
Lateral force rsistance of piles is analytically investigated by dividing the pile length to 3 segments. The first segment (Zone I) models the load eccentricity with respect to the soil and the pile-d
Jan 1, 1996
-
Professional Responsibilities In Sub-Surface Investigations For Foundations. - IntroductionBy D. J. Ketkar
It is a frequent experience to find that the Sub-surface Investigation (S.I.) data is either inadequate or misleading. However, such cases are rarely reported. Nonetheless, the projects suffer on-acco
Jan 1, 1996