    Hazard Mapping Combining Geostatistical Modeling Of Coal Mine Roof Quality Ratings With Numerical Modeling Of Stress Data

    By J. Riefenberg

    U.S. Bureau of Mines (USBM) researchers are developing a personal computer-based hazard mapping system for use in underground coal mines. Hazard mapping is rapidly gaining interest as delineating area

    Jan 1, 1994

  • SME-ICGCM
    Development Of A Remote Reading Dual-Height Telltale System For Monitoring Mine Roof Deformation

    By David Bigby

    A remote reading dual height telltale system has been developed to provide mine management with early warning of impending roof failure. This system is a logical development from the visual dual heigh

    Jan 1, 2001

  • SME-ICGCM
    Coal Mine Primary Support Selection: Tension Versus Non Tensioned Roof Bolt Systems

    By Kot Unrug

    The selection of tensioned versus non-tensioned roof bolts, for primary coal mine roof support, has been debated for well over 25 years. The wide spread use of fully grouted rebar marked the beginning

    Jan 1, 2004

  • SME-ICGCM
    Laboratory Testing of Rib Straps

    By E. Bane Kroeger

    Rib failure is a hazard that has resulted in many injuries and fatalities in underground coal mines, especially in soft coal seams. Conventional rib control methods including rib boarding, shotcreting

    Jan 1, 2004

  • SME-ICGCM
    The Role of Gas Pressure in Coal Bursts

    By Winton Gale

    "Rock and coal fractures and micro seismic vibration are common occurrences during development mining. It is very uncommon for coal and rock to be propelled into the roadway during normal mining opera

    Jan 1, 2018

  • SME-ICGCM
    A Possible Alternative To Hardwood Chock Pieces

    By B. G. D. Smart

    The development of a softwood alternative to the hardwood chockpiece used to build the waste-edge breakers commonly incorporated in gateroad packs is described. The results of laboratory tests on soft

    Jan 1, 1992

  • SME-ICGCM
    Evaluation Of Existing Predictive Methods For Mine Subsidence In The U. S. (1ec2d374-5864-4775-9b19-24759c4f95be)

    By Vladimir Adamek

    Two existing predictive methods were chosen for evaluation; an influence function (Gals Theory) and a profile function (hyperbolic). These were applied to several field measured subsidence pro¬files o

    Jan 1, 1981

  • SME-ICGCM
    Identification Of Critical Slope Failure Surfaces With Critical Tension Cracks

    The formation of tension cracks in slopes is well known. Analytical studies require the determination of a critical slip surface for any slope and, in doing so, it is necessary to consider an appropri

    Jan 1, 1989

  • SME-ICGCM
    Determination Of Rock Strength Properties Using Geophysical And Ultrasonic Logging In Exploration Drill Holes

    By John Feddock

    This study deals with underground mines and ground control and the prediction of seats strength characteristics based upon ultrasonic logging. Exploration drill holes, both rotary and core holes are u

    Jan 1, 2003

  • SME-ICGCM
    Application Of Tailing Sand And Water As Backfill Material In Metal Mines (1992)

    By Sun Henghu

    This paper analyses problems associated with cement based technique in metal mines, and provides a new mining technique of packing the tailing sand and water into solidified material. In the new techn

    Jan 1, 1992

  • SME-ICGCM
    The Design of Room and Pillar Mining Systems in the UK

    By Graham Daws

    State of the Art Room and Pillar mining techniques have been employed at two coal mines in the UK in the last two years. This paper describes the design of pillars and rockbolted support systems for R

    Jan 1, 1998

  • SME-ICGCM
    Effects Of Bedding Plane Sliding And Separation And Tensioned Bolt In Layered Roof

    3-D finite element modeling was performed to study the effect of bedding plane sliding and separation and tensioned bolt in layered root It was found that the major influence zones of a tensioned bolt

    Jan 1, 2001

  • SME-ICGCM
    An Investigation of the Causes of Cutter Roof Failure in a Central Pennsylvania Coal Mine: A Case Study

    By John L. Hill

    Cutter roof failure is a specific type of ground control problem which frequently results in massive roof failure. It is a cannon occurrence in coal mines of the Northern Appalachian Coal Sasin, causi

    Jan 1, 1984

  • SME-ICGCM
    Improving Stope Support At Modikwa Platinum Mine

    By Jaco J. van Vuuren

    Modikwa Platinum Mine, in the Eastern Bushveld of South Africa's Limpopo Province, is a new operation employing a hybrid mining method where mechanised methods are used for the main developments

    Jan 1, 2004

  • SME-ICGCM
    Weak Claystone Floors And Their Implications To Pillar Design And Settlement (e297de16-ba6b-46bd-8383-22a15beca7b5)

    By Ross W. Seedsman

    The in situ behaviour of claystone floors associated with the Wallarah, Great Northern and Fassifem Seams has been studied using a comprehensive suite of stress and displacement monitors. The instrume

    Jan 1, 1992

  • SME-ICGCM
    Determining Horizontal Stress Direction Using The Stress Mapping Technique

    By T. P. Mucho

    Mine roof failure due to excessive horizontal stress has been recognized as a major cause of hazardous roof conditions in some mines. Stress measurements gathered by the U.S. Bureau of Mines (USBM) at

    Jan 1, 1994

  • SME-ICGCM
    Determination And IT-Supported Evaluation Of Rock Mechanical Parameters And Their Utilization During Application Of Roof Bolting Techniques

    By Nikolaos Polysos

    For the planning and driving of gateroads supported by roof bolts a practical concept has been developed in order to determine the geological and rock mechanical parameters derived from exploration dr

    Jan 1, 2001

  • SME-ICGCM
    Skin Failure Of Roof And Rib In Underground Coal Mines

    By Eric R. Bauer

    Skin failures of roof and rib in underground coal mines continue to be a significant safety hazard for mine workers. Skin failures do not usually involve failure of the support systems but result from

    Jan 1, 1999

  • SME-ICGCM
    Operational Experience With FLEXIBOLT Systems In Australian Coal Mines

    Since the initial development and trials of FLEXIBOLT flexible roof bolts, further comparative testing and product development has been completed as part of the changeover to this roof support system

    Jan 1, 1994

  • SME-ICGCM
    Application Of Bolt Design Criteria At Galatia Mine

    By Tom Denton

    The bolt design criteria, since it was first published by Dr. John Stankus (Stankus, 1997), has been recognized as an important tool in ground control design. This concept is based on the Optimum Beam