    Settlement Control Of A Road Embankment Using Vertical Drains

    By Wei Tu

    A grade separation was required to allow uninterrupted traffic crossing for a busy rail spur and a county road. The grade separation was achieved by creating a 30-foot (9-meter) high embankment that

    Jan 1, 2009

  • DFI
    Presentation #7 - Bi-Directional Static Load Testing - Load Testing High Capacity Piles What Have We Learned?

    By Jorj Osterberg

    550 load tests of up to 150 MN have been completed on driven and bored piles using the Osterberg Load Cell. Because the test measures side shear and end bearing separately, much can be learned about t

    Jan 1, 2001

  • DFI
    LRFD For Deep Foundations: Replacing The Traditional Factor Of Safety In Design

    By Lance A. Roberts

    The Federal Highway Administration (FHWA) has mandated the use of the AASHTO Load and Resistance Factor Design (LRFD) specifications for all new federally-funded transportation infrastructure projects

    Jan 1, 2008

  • DFI
    Piled Raft Floats On Moraine

    By Terence P. Holman

    Instrumented load testing of high capacity micropiles, followed by detailed analysis and numerical modeling, provided an opportunity for real foundation performance to be incorporated into the design

    Jan 1, 2007

  • DFI
    The First Cut-Off Wall In The Indian Himalayas For The Dam Of The Dhauliganga Hydroelectric Project

    By Wolfgang G. Brunner

    In the far north of Uttar Pradesh Province in the Indian Himalayas, the 280 MW Dhauliganga hydroelectric power plant is under construction by National Hydroelectric Power Corporation (NHPC), a state-

    Jan 1, 2004

  • DFI
    Pile Driving Hammers In Centrifuge Modelling - Synopsis

    By Daniel Levacher

    Pile load tests in site require extensive means of action and time. To get outstanding tests, the environmental test conditions must be perfectly known and acceptable. They concern the support install

    Jan 1, 1996

  • DFI
    Deep Foundation Underpinning Support For Fort Monroe, Virginia YMCA Historic Building Renovation

    By David C. Kraft

    Atlas Systems, Inc. (ASI) resistance type piers were used to underpin a 100 year old historic structure at Fort Monroe, Virginia. This 3-story structure with basement was underpinned with 155 steel tu

    Jan 1, 2002

  • DFI
    Design Of Laterally Loaded Single Pile In Sand Near Slope - A Proposal For Subgrade Reaction Factors

    By Salim Mezazigh

    Usually different methods for designing a single pile submitted to a lateral loading are available. They are based on theory of elasticity with the parameters E,v or subgrade reaction method using the

    Jan 1, 2002

  • DFI
    Rock Socket Friction In Drilled Shafts - Its Greater Than You Think - Summary.

    By Jorj O. Osterberg

    The practice of using side shear resistance in the design of drilled shafts socketed in rock is discussed. In the absence of field test data for the particular rock involved, the designer often neglec

    Jan 1, 1991

  • DFI
    Design And Performance Of Helical Screw Piles In Collapsible And Expansive Soils In Arid Regions Of The United States

    By David R. Black

    Foundation problems due to collapsible and expansive soils are well known throughout the arid western United States. Millions of dollars are spent annually to counteract the effects of such soils for

    Jan 1, 2002

  • DFI
    The Resonant Driver: Ultra High Frequency Pile And Casing Installation

    By Matthew Janes

    The installation of piles and casings is becoming increasingly difficult as restrictions on vibration become common in major urban areas. The use of high frequency, resonant excitation of a pile or c

    Jan 1, 2008

  • DFI
    Large Diameter Pile Driving, Acceptance And Soil-Pile Setup New East Span San Francisco-Oakland Bay Bridge

    By Saba Mohan

    This study presents results based on the Pile Installation Demonstration Project (PIDP) that was conducted as a part of the East Span San Francisco-Oakland Bay Bridge Seismic Safety Project. For the t

    Jan 1, 2002

  • DFI
    Pile Installation Recorder Tests For ACIP/CFA Piles - Introduction

    By Garland Likins

    The Texas Department of Transportation, now considering using Augered Cast-In-Place (ACIP) Piles (also known as Continuous-Flight-Auger or CFA Piles) in their foundations, awarded a research project t

    Jan 1, 1998

  • DFI
    Seasonal Strain Distributions in Full-Scale Energy Foundations (720c13b2-b754-45d9-8b84-e88f10ec05b5)

    By Kyle Murphy, John S. McCartney

    This paper focuses on the seasonal thermo-mechanical response of two energy foundations installed at the new Denver Housing Authority Senior Living Facility in Denver, Colorado. The two drilled shaft

    Jan 1, 2017

  • DFI
    Estimation Of Horizontal Deformational Property Using A Pressuremeter Test For The Evaluation Of Lateral Bearing Capacity Of A Pile

    By Hyung-Min Kwon

    There are a number of methods available that can be used to estimate the bearing capacity of piles that are subject to lateral load, such as the theory of subgrade reaction or the elastic continuum ap

    Jan 1, 2008

  • DFI
    Keynote Lecture 6: Mitsuhiro Shibazaki Jet Grouting

    By Mitsuhiro Shibazaki

    Generally, water-soluble polymers are effective in convergence of water jet ejected from a nozzle as they add viscosity to water. However, excessive additional polymers (added to keep water viscous) c

    Feb 10, 2003

  • DFI
    Current Business Trends In The People's Republic Of China ? Synopsis

    By V. Tang

    In this paper, Chinese economic situation are estimated and prospective developments predicted to assist those US firms who have been trying to do business in China, or are considering to pursue the C

    Jan 1, 2010

  • DFI
    Keynote Lecture 3: G. Stuart Littlejohn Compensation and Permeation Grouting

    By G. Stuart Littlejohn

    In spite of recent concerns in certain European countries, I believe that silicate-ester grouts will continue to be employed in practice, unless more cost-effective inorganic grouts are developed for

    Feb 10, 2003

  • DFI
    Session 19 "Compensation Grouting"

    By Douglas Heenan

    The fracture orientations were inferred based on theory and previous experience. The fracture pattern was not monitored during the project. Grout volume was recorded at each sleeve port and real time

    Feb 10, 2003

  • DFI
    Session 13 "Jet Grouting III"

    By Peter Iovino

    Unfortunately, I don't know the unit cost per cubic yard of treatment. I reflected on that yesterday and I don't think that we considered the use of micropiles. They could have been an optio

    Feb 10, 2003