Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Pile Testing Methods - Authors' Presentations. - Paper 9.1 An Innovative Approach To Load Testing Of High Capacity Piles

    By W. G. K. Fleming

    Mr P. Bermingham introduced paper 9.1, describing the development and trials of a new pile load-testing technique that the Authors had termed "Statnamic". The system involved launching a test weight m

    Jan 1, 1991

  • DFI
    Case Studies/case Histories In Geotechnical Engineerin: Enhancing The Practice In An Interactive Learning Environment

    By Waddah Akili

    This paper describes the steps taken in planning, developing, and executing a case study/ case history course in geotechnical/ foundation engineering at an international university. The paper sheds li

  • DFI
    Current State of Practice of Corrosion Protection in Europe with Hollow Bars - Comparison to Methods Being used in North America

    By Alice Y. Tseng, Dan MacLean

    "Corrosion protection of all deep foundation systems made of steel is THE issue when considering durability of the element in the long term. Protecting steel from corrosion and maintaining the steel t

    Jan 1, 2017

  • DFI
    London One New Change - Energy Piles® And Open Loop Wells Used For Ground Source Heating And Cooling

    By Peter Smith

    One New Change is a landmark retail / commercial development in the City of London. Integral to the structure is the three double storey basement from which the building is serviced. The building cons

    Jan 1, 2010

  • DFI
    Rehabilitation of the Kölnbrein Dam / Austria

    By Frank Haehnig, Kurt Kogler

    "With a height of 200 m, a crown width of 626 m and a concrete volume of 1.6 million m³, the Kölnbrein Dam in the upper Malta valley in Carinthia / Austria is the largest concrete dam in Austria. Boas

    Jan 1, 2016

  • DFI
    DFI45 Annual Conference on deep Foundations 2020

    By DFI DFI

    An Online Conference

  • DFI
    A Case History on Design, Construction, and Performance of Stone Column Ground Improvement beneath an MSE Embankment

    By Dominic Parmantier, Karen Dawson, Suthan Pooranampillai, Seungcheol Shin

    "This paper presents a case study of the deformation-based design, construction, and performance of stone column ground improvement (GI) beneath a mechanically stabilized earth (MSE) wall and bridge a

    Jan 1, 2017

  • DFI
    Uncertainties In CSL Test Interpretations And Recommendations Toward A More Efficient Process

    By Rohrbach

    Crosshole Sonic Logging (CSL) testing is commonly used to verify the integrity, quality and ultimately the acceptability of the concrete in structural elements such as drilled shaft foundations, secan

  • DFI
    Field Testing Of Energy Piles At Virginia Tech

    By Olgun

    Energy piles are a new innovative renewable energy technology to access and exploit the relative constant temperature of the ground for efficient heating and cooling of buildings. Examples of energy

  • DFI
    Deep Compaction Using Vibratory Pile Hammers

    By Dennis Nottingham

    The need for deep compaction of submerged granular soils has led to improvements in this area. In 1971, L.B. Foster Company personnel patented a method of deep compaction using a vibratory pile hammer

    Jan 1, 2013

  • DFI
    Underpinning And Micropiling To A Four Storey Apartment Building In Hamilton, Scotland

    By Clifford J. Wren

    A geotechnical foundation solution was required to halt and prevent further structural distress suffered by a residential four storey apartment building in Hamilton, Scotland. Residents of the ten ye

    Jan 1, 2008

  • DFI
    The Influence Of RC Nonlinearity On P-Y Curves For CIDH Bridge Piers (1bc0f905-8225-4716-af5c-0878cbc0d1a4)

    By Leonardo Massone

    The p-y method is one of the most popular methods in pile design and has been calibrated for various boundary conditions using numerical and experimental studies during recent years. Most studies on r

    Jan 1, 2011

  • DFI
    Ground Improvement For The Deep Foundation Of A 650 M Long Quay Wall In The Port Of Hamburg

    By Peter Arz

    In the port of Hamburg a 650 m long quay wall was completed in mid-1985. The watertight wall consists of loadbearing steel buttress piles PSP 1012 which are up to 28 m long and infill interlocking she

    Jan 1, 1987

  • DFI
    Design And Construction Of The Sutong Bridge Foundations

    By Robert B. Bittner

    The Sutong Bridge across the lower Yangtze River in China will have, when completed, the longest span (1,088 m) and the highest towers (306 m) of any cable stayed span in the world. The foundations f

    Jan 1, 2013

  • DFI
    Tower Leg Foundation Assessments with Frequency Response and Impedance Profiling Techniques

    By Huw Williams

    "Power companies are always looking to increase the carrying capacity of existing transmission lines, and the preferred method is to string heavier capacity conductor lines. However this results in hi

    Jan 1, 2005

  • DFI
    Integration Of Real Time Pile Design By Means Of Building Information Modeling

    By Prof. Dr. -Ing. habil. Sascha Henke, Johannes Beck

    The growth of Building Information Modeling (BIM) during recent years opens possibilities for integrating new digitally driven design approaches. While parametric design and algorithmic design slowly

    May 1, 2022

  • DFI
    Trencher Method Vs. Slurry Trenching: A Pros & Cons Comparison Of Case Studies

    By Daniel Ruffing, Charlie Krug

    In recent years, the chain-style trencher has been proven a valuable tool for installing vertical walls on challenging sites where conventional methods may be less desirable. Like many tools, trencher

  • DFI
    Characteristics And Application Potentials Of Ground Improvement With Semi-Rigid Inclusions Based On An Innovative Composite Of Polymers And Gravel

    By Pratter P., Boley C.

    Polymers are well established in geotechnical applications, for example in ground improvement, where the polymers act as a binder that, when cured, holds the grains together by adhesive and cohesive f

    May 1, 2022

  • DFI
    Bearing Capacity of Post Grouted Drilled Shafts Using a Load Transfer Approach

    By Miguel E. Ruiz, America L. Fernandez, Miguel A. Pandon

    "Post-grouted drilled shafts (PGS) are a deep foundation system in which grout is injected at high pressure throughout the tip after the drilled shaft has been installed. Pressure grouting of drilled

    Jan 1, 2005

  • DFI
    Session 24 "Compaction Grouting and Consensus Guide"

    By Richard Berry

    The spacing of grout injections is typically about 2 to 2 V½ meters if the purpose of the grouting is densification of the in-situ soils. Hole spacing will vary with the in-situ soil properties and th

    Feb 10, 2003