Search Documents
Search Again
Search Again
Refine Search
Refine Search
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
-
Ground Control of Strip Backfilling Water Conservation Mining in Shallow Coal SeamsAccording to the classification of water conservation mining in shallow coal seams in China, when the ratio of the impermeable layer thickness to the mining height is less than 18, the mining belongs
Jan 7, 2020
-
Ground Control Practice at Leeville Underground MineBy Changshou Sun
The geotechnical properties of mining zones at Leeville Underground mine (or simply called Leeville mine through this paper) are different from one zone to another. The typical ground condition is poo
Jan 1, 2013
-
Ground Control Problems And Possible Remedial Measures At An Underground Coal MineBy S. M. Hsiung
This paper presents the results of an extensive study concerning a series of roof falls in a room-and-pillar coal mine located in West Virginia. Three dimensional finite element modeling was employed
Jan 1, 1985
-
Ground Control Procedures in Western Australian Underground Mines - a Critical ReviewA review of ground control procedures in Western Australian underground mines is presented. Geotechnical input into initial mine design and methods of ground control is rare. As a result, the frequenc
Jan 1, 1992
-
Ground Control Research At A Sandstone MineBy M. Ge
Pattison Mine is a small sandstone mine located in Iowa. The sandstones produced by the mine are not common construction and aggregate materials. The stones are used to produce a special type of sand
Jan 1, 2012
-
Ground Control Studiers in the Humphrey No. 7 Mine Christopher Coal Division Consolidation Coal CompanyBy H. D. Dahl
In January, 1969, the Central Research Division of Continental Oil Company initiated a research program on roof control. The purpose of the research was to improve roof stability. Toward this end, it
Jan 1, 1971
-
Ground Control Techniques Utilizing Polymer Grid StructuresLightweight polymer grids have recently been introduced to the mining industry. They are currently being used for roof and rib control, longwall shield recovery, safety guarding or barricade, high
Jan 1, 1992
-
Ground Control Tools in Underground Coal Mining Conveniences and PrecautionsBy S. Bhattacharyya
"Coal bearing rocks are low in strength and have geological discontinuities and moisture sensitivity. Roof and rib falls have been a major cause of fatalities in underground coal mines. Mine engineers
Jan 1, 2015
-
Ground Deformation In The Case Of Underground Mining Of Thick And Dip Coal Seams In The Jiu Valley BasinBy Gheorghe Oncioiu
The phenomena developed on the influence of thick coal seam no.3 mining, by horizontal slices and rocks caving roof control, in the Jiu Valley coal basin, are very complex. By analyzing the influence
Jan 1, 1999
-
Ground Disturbance Due to Static Pressure Driving of Opened-Ended PHC PilesBy Xiaocen Lu, Guowei Li, Jiantao Wu, Thang N. Nguyen, Andrew C. Amenuvor
"This paper investigates the effect of driving a group of 52 open-ended Prestressed High Strength Concrete (PHC) piles on an existing highway embankment based on field measurements of excess pore pres
Jan 1, 2016
-
Ground Fall Injuries In Underground Stone Mines – SummaryWorkers in underground stone mines have a high fatality rate caused by falls of ground from the mine roof or rib. NIOSH recommendations to reduce ground fall injuries and deaths address baskets, mecha
Jan 11, 2003
-
Ground Freezing 10 Control Ground Water And Support Deep Storm Sewer Structural ExcavationsBy John A. Shuster, Joseph A. Sopko
Construction of two shafts, as well as associated deep concrete structures, for a major storm sewer project in Milwaukee, Wisconsin required ground water control and temporary ground support to depths
Jan 1, 1989
-
Ground Freezing A Proven Technology In Mine Shaft SinkingBy Paul C. Schmall
The link between artificial ground freezing and the mining industry stretches back more than 140 years, and across an ocean. Patented by the German scientist F.H. Poetsch in 1863, the technique is re
Jan 1, 2007
-
Ground Freezing As Used In The Excavation Of A Mixed FaceBy John E. Feddcck
New York City's $360 million North River Water Pollution Control Project is part of New York State's plan to clean up the Hudson River. The project is to provide a sewage treatment facility
Jan 1, 1970
-
Ground Freezing Combined Method for Urban Tunnel ExcavationBy Filippo Mira-Cattò, Andrea M. R. Pettinaroli, Elena Rovetto
"The construction of Powisle station of Metro Warsaw Line 2, in Poland, required the execution of two shafts next to an urban road tunnel adjacent to the Vistula River. The shafts were linked by three
Jan 1, 2015
-
Ground Freezing Deep Shaft Excavation Shaft 17B-1 New York City Water Tunnel No. 3 New York, New York - RETC2023By Andrew Chegwidden, Tara Wilk
Construction of Shaft 17B-1, a part of The New York City water supply system, required an excavation of approximately 38 m (123 ft) through water-bearing overburden soil and more than 152 m (500 ft) o
Jun 13, 2023
-
Ground Freezing for Boston Central Artery Contract Section C09A4, Jacking of Tunnel BoxesBy Paul C. Schmall, John F. Donohoe, Arthur B. Corwin, Derek Maishman
Ground freezing was utilized to provide complete stability of the excavation face and complete groundwater cut-off for the jacking of the three tunnel boxes for the Interstate 90 / Interstate 93 appro
Jan 1, 2001
-
Ground Freezing for Construction at the Port of Miami TunnelBy Roger Storry, Arnaud Hochart, David Harris, Olivier Martin
"INTRODUCTIONThe Port of Miami Tunnel (POMT), designed and constructed by Bouygues Civil Works Florida between 2009 and 2014, was a Public Private Partnership between the Miami Access Tunnel Concessio
Jan 1, 2016
-
Ground Freezing for Deep Shaft Excavation Shaft 18B-1 New York City Water Tunnel No. 3 New York, New York - NAT2024By Andrew Chegwidden, Tara Wilk
Shaft 18B-1 is the second shaft to be constructed as a part of contract C547A along the New York City water supply system Tunnel No. 3. More complex than Shaft 17B-1, this site has an additional 30 m
Jun 23, 2024
-
Ground Freezing for Groundwater Cutoff at the Seattle Seawall Replacement ProjectBy Brenton Cook, Daniel Mageau, Larry Applegate, Aaron McCain
"Ground freezing was successfully used to create an impermeable barrier wall along 3,000 feet of the downtown Seattle waterfront as part of the Seattle Seawall Replacement Project. This $360 million r
Jan 1, 2016