Search Documents
Search Again
Search Again
Refine Search
Refine Search
-
Low-Frequency Blast Vibrations at a High Water-Table SiteBy Mark S. Stagg, David E. Siskind, Stephen V. Crun, Willard E. Pierce
The USBM is studying the impacts of low-frequency blast vibrations on residences to assess both response and cracking potential. Complementing coal mining sites monitored in the midwest and east, vibr
Jan 1, 1996
-
Significant Sources of Error in the Seismograph Error BudgetBy Gregory Lorsbach, Wade Hutchison, Earnest Grigoryan
Comparing measurements from multiple seismographs, particularly when the instruments are deployed in a “side-by-side” situation, is often problematic. Measurements often differ by as much as a factor
Jan 1, 2005
-
Minimum Burning Pressures of Commercial ExplosivesBy P. D. Lightfoot, C. Badeen, R. Turcotte, D. E. C. Jones
Following localized (i.e. hot-spot) ignition, there is a minimum pressure required for combustion to propagate in water-based commercial explosives. The latter is usually referred to as the ‘Minimum B
Jan 1, 2004
-
Cap Testing at the Minntac MineBy Jack Eloranta
To improve control of blasting, tests were performed to assess non-electric cap accuracy. Simultaneous testing using a Velocity of Detonation Recorder (VODR), Red Lake LoCam and an Instantel DS-677 bl
Jan 1, 1992
-
Open-Pit Blast Vibration PredictionBy Jaak J. K Daemen, Carol Geertson
A portion of a tailings impoundment may need to be removed with the expansion of an open-pit mine in northeastern Nevada. The tailings are saturated and consist of fine silty soil. During the removal
Jan 1, 1998
-
The Efficiency of Blasting Versus Crushing and Grinding (b74142ad-057d-4d47-8cdb-a72f6046d338)By Jack Eloranta
This paper compares energy requirements for blasting, crushing and grinding. By tracking electrical consumption for various powder factors, a general trend has appeared. This study involves over 100 m
Jan 1, 1997
-
Advanced Analysis of Airblast and Vibration Signals for Optimizing Blast DesignBy Frank Sames
Blast vibration and airblast overpressure signals are generally rated and compared only by their maximum amplitude and the principal frequency associated with the peak pulse. The scaled distance conce
Jan 1, 1997
-
The Effect of Water Table on Peak Particle Velocities from Blasting OperationsBy Michael Beattie
A large open-cast limestone mine had its blasting operations severely restricted by the imposition of limiting PPV levels to protect a water pipe-line passing through the mine property. Attempts were
Jan 1, 1992
-
Single Round Blasting of 10 Food Diameter x 65 Foot Depth Emplacement Shaft Collars at the Mercury, Nevada Test SiteBy Tom Short, Bill Beam
Some of the weapons testing shafts at Mercury, Nevada require depths of 1000ft and diameters of 10 feet. The top 40 feet to 65 feet is drilled, blasted and excavated by Large caisson type augers in or
Jan 1, 1991
-
Parameters Affecting the Thermal Behaviour of Emulsion ExplosivesBy Robert C. Fouchard, Gordon Chalmers, David E. G. Jones, Ivana Alilovic, Phillip D. Lightfoot
There have been numerous international instances over the last several years in which pumping emulsion explosives has resulted in accidents, apparently as a result of increased thermal sensitivity und
Jan 1, 2000
-
What SEE Has Done For Me: The Value of the Scholarship ProgramBy Jim Daley
SEE is a dynamic organization composed of people from all facets of the explosives industry who are truly interested in the advancement of that industry. I had been a miner at the Homestake Gold Mine
Jan 1, 1995
-
The Science and Testing Behind Quantitative Risk Assessment ModelsBy Michael Swisdak, John Tatom
In a quantitative risk assessment (QRA), the ability to accurately model real-world situations is obviously critical. In the end, the model must be able to represent the effects produced by the detona
Jan 1, 2007
-
New Containment Methods against Forest-Fires based on the Use of ExplosivesBy Winfried Rosenstock, Hans-Jochen Blatte
"The guidelines of fire-fighting strategies have to be rewritten, latest since theYellowstone-Fire.CF- and S3- procedure are developed to achieve firelines of 500 ms/ h length and 100 mswidth per unit
Jan 1, 1993
-
Journal: 20th Annual Photo and Art Contest - Honorable Mention "Snoqualmie Pass"By Corry Goumans
Photos 1 - 4 – Chris Elliott is a rock slope supervisor on a construction project east of Seattle, Washington. His job is to look after a “two man” scaling crew working on the rock bluffs some 300 fee
Jan 1, 2014
-
Preparing for Blast Damage Litigation Through Accurate Record DocumentationBy Keith Pucalik
One of the more important duties of the vibration consultant is to evaluate allegations of blasting damage by neighboring property owners. Unfortunately, the consultant is generally faced with having
Jan 1, 1990
-
Experimental Research on Thermal Ignition for Emulsion Powder Explosives and Emulsion MatrixBy Li Jianjun, Zhang Xiaozhi, Guan Li, Jin Jinzhe
People used to regard emulsion explosives as the safest industrial explosives. But in the process of manufacturing emulsion explosives spontaneous ignitions of the remnant emulsion matrix have happene
Jan 1, 1998
-
Creating Awareness About Carbon Monoxide - Blasters Should Know About the Silent HazardBy Unknown
[Executive Director’s note: According to 17th edition of the ISEE Blasters Handbook in its section on trench blasting, “...consideration must be given to the proper venting of gases generated from the
Jan 1, 2002
-
Cast Blasting: Design and ApplicationsBy Travis Watts, Chris Prater, G. T. Lineberry
Moving overburden at minimal cost is becoming increasingly important to coal mining companies throughout the U.S. The coal market is currently doing well, with an average spot coal price for Central A
Jan 1, 2006
-
Repumpable Emulsion SlurriesBy R DeLon Hunsaker
In the past, quarrying and other small operations have not been able to take advantage of the lower cost, convenience and better performance of bulk slurries. However, with the introduction of repumpa
Jan 1, 1984
-
Electric Explosive Tube Initiation SystemBy Richard N. Snyder
In this system for connecting blasting caps to the initiation source, the need for a redundant design structure provides more reliable method of explosive initiation. This is accomplished by using a c
Jan 1, 1995