    OFR-118-80 Measurement And Control Of Respirable Dust In Mines - Executive Summary And Recommendations

    A maximum acceptable level of 2 mg/m3 of respirable coal mine dust in active mine workings was established, effective January 1, 1973, under the Federal Coal Mine Health and Safety Act of 1969. It is

    Jan 1, 1980

  • NIOSH
    Use of a Directional Spray System Design to Control Respirable Dust and Face Gas Concentrations Around a Continuous Mining Machine

    By Gerrit V. R. Goodman

    A laboratory study assessed the impacts of water spray pressure, face ventilation quantity, and line brattice setback distance on respirable dust and SF6 tracer gas concentrations around a continuous

    Jan 1, 2004

  • NIOSH
    Frictional Ignitions In Underground Bituminous Coal Operations 1983-2005

    By Steven J. Schatzel, Robert B. Krog

    Frictional ignitions are defined as the ignition of a flammable mixture of methane and air that is initiated by frictional heating. Ignitions created through the addition of energy from open flames a

  • NIOSH
    OFR-83(1)-78 XVI International Conference On Coal Mine Safety Research - I Electrical Apparatus - Study Of Means For Increasing Intensity Of Current That Can Circulate Through An Intrinsically Safe Resistive Circuit - Introduction

    By A. Monomakhoff

    If a conductor traversed by an electric current is broken, a conduction forms in the air between the two broken ends of the wire. This conduction manifests itself in an initial phase by an electric sp

    Jan 1, 1975

  • NIOSH
    Failure Mechanics Of Multiple Seam Mining Interactions

    By R. Karl Zipf

    Multiple seam mining interactions caused by full extraction mining, whether due to undermining or overmining, frequently involve tensile failure of the affected mine roof. The adverse ground control

  • NIOSH
    Evaluation Of The Impact Of Standing Support On Ground Behavior In Longwall Tailgates

    By Thomas M. Barczak, Dennis R. Dolinar, Gabriel S. Esterhuizen

    Longwall mines typically use some form of standing support for secondary roof support in longwall tailgate entries. Although there have been several new support products developed for this applicatio

  • NIOSH
    RI 5754 Removing Quartz And Other Impurities From Refractory Clays By Mineral Dressing Methods ? Introduction And Summary

    By W. A. Calhoun

    The purpose of this investigation was to develop economical mineral dressing processes for removing objectionable quantities of impurities, such as quartz and pyrite, from refractory clay deposits in

    Jan 1, 1961

  • NIOSH
    Technology News - No. 514 - The Air Quantity Estimator (AQE): A New Computer Software Tool For Large-Opening Mine Ventilation Planning

    To provide operators of large-opening mines with a ventilation planning tool that will help them develop a healthier, safer, and more efficient ventilation system in the underground workplace.

    Jan 3, 2006

  • NIOSH
    Practical Experiences With Application Of The Coal Mine Roof Rating (CMRR) In Australian Coal Mines

    By David Hill

    The Australian underground coal mining industry has made extensive use of the Coal Mine Roof Rating (CMRR) classification system for a diverse range of purposes in recent years. These include mining m

    Jan 5, 2007

  • NIOSH
    Application Of Parametric Column Analysis To Evaluate Eccentric Loading Conditions On Prop Support Performance

    By D. Gearhart

    Full-scale tests are conducted on mine roof supports using protocols developed by the National Institute for Occupational Safety and Health (NIOSH) using the unique capabilities of the Mine Roof Simul

  • NIOSH
    RI 7640 - Methane And Dust Control By Water Infusion - Pittsburgh Coalbed (Fairview, W. Va.)

    By R. P. Vinson, Abdurrahman Cetinbas, Joseph Cervik, M. G. Zabetakis

    The effect of water infusion on the flow of methane and on the production of dust was investigated at an active face in the Pittsburgh coalbed. The average total flow of methane at the face decreased

    Jan 1, 1972

  • NIOSH
    Development And Application Of The Coal Mine Roof Rating (CMRR)

    By Gregory M. Molinda

    The Coal Mine Roof Rating (CMRR) was developed 10 years ago to fill the gap between geologic characterization and engineering design. It combines many years of geologic studies in underground coal min

    Jan 5, 2007

  • NIOSH
    Weak Rock Mass Design For Underground Mining Operations

    By Rimas Pakalnis, Andrea M. Ouchi, Thomas M. Brady, Mary M. MacLaughlin, Cristian Caceres, Paul Hughes

    A major focus of ground control research presently being conducted by the Geomechanics Group at the University of British Columbia, Canada, in conjunction with the National Institute for Occupational

    Jan 5, 2007

  • NIOSH
    Acceleration And GPS Data Monitor Truck-Haulage Jolts

    By J. Walden, J. Rhoades, R. E. Miller, R. Gibbs, P. Boman

    Accelerometers and pressure transducers, mounted in suspension components, can be used to monitor the ride of haulage trucks. Presently, it is difficult to tell what caused a jolt to the truck using e

  • NIOSH
    A Computer Software Program That Estimates Air Quantity Requirements In Large Opening Stone Mines

    By R. H. Grau, S. B. Robertson, J. Dolgos, T. P. Mucho

    The National Institute for Occupational Safety and Health (NIOSH) has developed a computer program called the Air Quantity Estimator (AQE). The purpose of the program is to provide a starting point fo

  • NIOSH
    Advances In Mine Emergency Communications

    By Jeff Kravitz, John Kovac, Wayne Duerr

    Since 198 1, Federal mining law has required every miner working in underground coal mines to have a self-contained, self-rescuer (SCSR) available for use in emergencies. Some miners that have escaped

  • NIOSH
    Development Of New Protocols To Evaluate The Transverse Loading Of Mine Ventilation Stoppings

    By T. J. Batchler, T. M. Barczak

    The Code of Federal Regulations (CFR) requires that the transverse load capacity of stoppings be equal to or greater than traditionally accepted in mine controls, which for block stoppings is generall

  • NIOSH
    IC 9483 - Water Well Safety Bits

    By Dana C. Reinke

    Water well drillers are exposed to high levels of noise while working. NIOSH researchers have found that water well drillers are exposed to levels above 85dB (A) while performing certain tasks during

    Jan 9, 2005

  • NIOSH
    RI 9427 - Large-Scale Strata Response to Longwall Mining: A Case Study

    By K. Y. Haramy, R. O. Kneisley

    This U.S. Bureau of Mines report summarizes a study of large-scale strata response to longwall mining at a western U.S. coal mine. This study utilized surface and subsurface measurements, geologic map

    Jan 1, 1992

  • NIOSH
    RI 9203 - Computer Modeling of Dust and Forces for Longwall Mining Systems

    By B. D. Hanson

    An interactive computer program has been developed by the Bureau of Mines which enables the user to identify the effect of cutting system changes on relative dust generation for longwall shearer drums

    Jan 1, 1988