Vertical And Lateral Load Tests On Driven And Cast-In-Place Piles ? Synopsis

Deep Foundations Institute
G. Price
Organization:
Deep Foundations Institute
Pages:
6
File Size:
545 KB
Publication Date:
Jan 1, 2010

Abstract

The Building Research Establishment installed a base load cell in a driven cast-in-place pile prior to it being tested under vertical load. The monitored base loads were found to be significantly less than could have been predicted by current design methods. The less than expected capacity was attributed to the drilling out procedure. An electro-level system installed in a second similarly formed pile, provided detailed information on the performance of the pile under lateral load. The information obtained was used to check several current design methods for laterally loaded piles. The findings show the potential dangers of attempting to improve design parameters from only limited performance data.
Citation

APA: G. Price  (2010)  Vertical And Lateral Load Tests On Driven And Cast-In-Place Piles ? Synopsis

MLA: G. Price Vertical And Lateral Load Tests On Driven And Cast-In-Place Piles ? Synopsis. Deep Foundations Institute, 2010.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account