Ventilation of the Northern Mujsky Railway Tunnel

- Organization:
- Society for Mining, Metallurgy & Exploration
- Pages:
- 8
- File Size:
- 292 KB
- Publication Date:
- Jan 1, 2009
Abstract
The choice of ventilation schemes in the Northern Mujsky railway tunnel and definition of the nec-essary quantities of air ensuring regulated radiation conditions in the tunnel system has been accomplished. The influence of natural draught on the stability of tunnel ventilation has been estimated. The design of a portal venti-lation gate allowing minimal influence from natural factors is described. The dependence of pressure loss in the sliding ventilation gates on their spanning value of the vehicle tunnel section has been determined. The selection of parameters for an atmospheric air heating system in winter has been carried out. The operation regimes of air heaters, dependent on the temperature of atmospheric air, have been established.
Citation
APA: