The development and use of short-lived radioactive tracer methods for the onstream determination of residence time distributions in large-scale ball mills is described. Tests are reported on a pilot-plant ball mill with 0.43 m diameter and 0.86 m length and on an industrial mill with 1.83 m diameter and 2.74 m length. Tests with different tracer feed sizes indicate that the residence time distributions on both mills are independent of charge particle size. Similar tests are planned for a large ball mill of 4.57 m diameter and 9.30 m length. No safety problems were encountered in these tests and none are anticipated in tests of the larger mill.
Citation
APA:
(1981) The On-Stream Determination of Large Scale Ball Mill Residence Time Distributions with Short-Lived Radioactive Tracers (cb43db45-9710-45b5-95b1-0cb64fb2c2e9)MLA: The On-Stream Determination of Large Scale Ball Mill Residence Time Distributions with Short-Lived Radioactive Tracers (cb43db45-9710-45b5-95b1-0cb64fb2c2e9). The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1981.