Abstract
The development and use of short-lived radioactive tracer methods for the on-stream determination of residence time distributions in large-scale ball mills is described. Tests are reported on a pilot-plant ball mill with 0.43 m diameter and 0.86 m length and on an industrial mill with 1.83 m diameter and 2.74 m length. Tests with different tracer feed sizes indicate that the residence time distributions on both mills are independent of charge particle size. Similar tests are planned for a-large ball mill of 4.57 m diameter and 9.30 m length. No safety problems were encountered in these tests and none are anticipated in tests of the larger mill.
Citation
APA:
(1978) The On-Stream Determination Of Large Scale Ball Mill Residence Time Distributions With Short-Lived Radioactive TracersMLA: The On-Stream Determination Of Large Scale Ball Mill Residence Time Distributions With Short-Lived Radioactive Tracers. Society for Mining, Metallurgy & Exploration, 1978.