Study On Damage Mechanism Of Ductile Cast Iron Cooling Stave

- Organization:
- The Minerals, Metals and Materials Society
- Pages:
- 8
- File Size:
- 1140 KB
- Publication Date:
- Jan 1, 2015
Abstract
The damage mechanism of ductile cast iron cooling stave applied to No.4 blast furnace of Guofeng steel was analyzed through damage investigation in details, the damage causes: hightemperature gas flow erosion, wear of burden, high-temperature ablation, carburizing damage, improper operation on blast furnace, etc. were given out both in macroscopic and microscopic views. It can be obtained from metallographic diagrams that the diameter of graphite nodules increases, the number per unit area reduces, and roundness declines, successively, from cold to hot surface, which are not conducive to stave longevity. In summary, the material for staves manufacture should be better in comprehensive mechanical properties to prolong the service life, thus making blast furnace long campaign.
Citation
APA:
(2015) Study On Damage Mechanism Of Ductile Cast Iron Cooling StaveMLA: Study On Damage Mechanism Of Ductile Cast Iron Cooling Stave. The Minerals, Metals and Materials Society, 2015.