Abstract
"Both COD and TOC can characterize organic pollution of coking wastewater. In theory, there is a linear correlation between these two indicators. After continuous monitoring TOC and COD of coking waste water, linear regression relationship between of these to indicators was studied with the use of mathematical statistics. And conversion equation between these two indicators was established, and using t-test method for significance testing. The results showed that the linear relationship of COD and TOC was significant. Also interval estimation of equation slope and intercept were given in the condition of 95% confidence level. A linear regression equation established can be used to indirectly convert TOC to COD with high precision and accuracy.IntroductionBoth chemical oxygen demand (COD) and total organic carbon (TOC) are measure of the degree of characterization for organic pollution of water bodies. The current COD standard analytical methods is Potassium dichromate titration method [1] . there are some disadvantages in this method, such as only part of organic matter in the water bodies being oxidated, the refluxed steps, a long time needed for each measurement, high cost. It is the most important that sulfuric acid silver and mercury sulfate reagents used in the measurement may easily lead to secondary pollution. In contrast, the measurement of TOC is by the method of combustion or Photocatalytic Oxidation. The result could be easily got from the instrument. There are some advantages in this way, such as easy operation, short time and little expenses for each measurement and no secondary pollution 121• In addition, the measurement of TOC has higher degree of precision and accuracy than the measurement of COD both in the determination of calibration standards and actual samples. The meaning and contrast of TOC and COD are listed in the table 1."
Citation
APA:
(2013) Study on Correlation between COD and TOC of Industrial WastewaterMLA: Study on Correlation between COD and TOC of Industrial Wastewater. The Minerals, Metals and Materials Society, 2013.