RI 9229 - Intercomparison Of North American Radon Progeny Measurement Methods And Equipment

The National Institute for Occupational Safety and Health (NIOSH)
T. H. Davis
Organization:
The National Institute for Occupational Safety and Health (NIOSH)
Pages:
12
File Size:
225 KB
Publication Date:
Jan 1, 1989

Abstract

Twelve laboratories from the Western United States and Canada participated in radon progeny intercomparison measurements at the U.S. Bureau of Mines radon calibration facility in March 1987. The participants intercom pared grab-sampling and automated equipment methods at high and low concentrations of radon progeny and condensation nuclei (CN). The objective of this intercomparison was to determine if the measurement procedures and equipment of the North American facilities are equivalent. The sampling results showed good agreement among all participants. The standard deviation for the working level measurements was less than 3.5% for 1.70 working level (WL) and less than 8.8% for 0.21 WL. This relatively good agreement was achieved by using alpha standards calibrated by National Bureau of Standards (NBS) and by closely checking and monitoring airflows.
Citation

APA: T. H. Davis  (1989)  RI 9229 - Intercomparison Of North American Radon Progeny Measurement Methods And Equipment

MLA: T. H. Davis RI 9229 - Intercomparison Of North American Radon Progeny Measurement Methods And Equipment. The National Institute for Occupational Safety and Health (NIOSH), 1989.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account