RI 9152 - Laboratory Assessment of Alternative Longwall Stabilization Materials

The National Institute for Occupational Safety and Health (NIOSH)
Deno M. Pappas
Organization:
The National Institute for Occupational Safety and Health (NIOSH)
Pages:
19
File Size:
6104 KB
Publication Date:
Jan 1, 1988

Abstract

The objective of this Bureau of Mines investigation was to identlfy and evaluate alternative binder materials for use in stabilizing and consolidating highly fractured roof along longwall faces and gate roads. The desirable characteristics of a stabilization material were defined, and an extensive search was conducted to find materials satisfying these characteristics. Of 20 materials originally scrutinized, 9 were chosen for laboratory analyses. The laboratory tests evaluated bond strength and tensile strength under both dry and wet conditions. An optimum material was not found. The laboratory analyses indicated two possible candidate materials for longwall stabilization: high-aluminous cement and two-component epoxy; however, the tensile strength of the high-aluminous cement was mediocre, and the epoxy cement is toxic, flammable, and fairly expensive. The potential market demand for an effective and economical stabilization macerial is discussed in the appendix.
Citation

APA: Deno M. Pappas  (1988)  RI 9152 - Laboratory Assessment of Alternative Longwall Stabilization Materials

MLA: Deno M. Pappas RI 9152 - Laboratory Assessment of Alternative Longwall Stabilization Materials. The National Institute for Occupational Safety and Health (NIOSH), 1988.