RI 8258 Cylindrical Duct Fire Spread

The National Institute for Occupational Safety and Health (NIOSH)
John C. Edwards
Organization:
The National Institute for Occupational Safety and Health (NIOSH)
Pages:
36
File Size:
1548 KB
Publication Date:
Jan 1, 1977

Abstract

A two-dimensional, time-dependent, mathematical model has been developed that describes fire spread along the walls of a ventilated duct. The model is based on the assumption that the leading edge of the fire zone propagating along the wall surface coincides with the isotherm for the fuel ignition temperature. The model includes gas-phase energy transport via radiation and forced convection inside the duct and solid-phase energy transport by conduction into the fuel lining. Product gases emitted from the fire zone are assumed to mix uniformly with the ventilation gas to produce an optically dense gas mixture at the combustion temperature that enters the preheat region. Numerical solutions of the model equations for a coal-lined duct (simulated coal mine entry) have been used to investigate the effects of tube radius, air velocity, combustion temperature, and optical density of the soot-laden gas upon the terminal fire spread rate.
Citation

APA: John C. Edwards  (1977)  RI 8258 Cylindrical Duct Fire Spread

MLA: John C. Edwards RI 8258 Cylindrical Duct Fire Spread. The National Institute for Occupational Safety and Health (NIOSH), 1977.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account